Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} outputs 49,763 W AC at 480 V, 3-phase (59.9 A continuous, 80 A OCPD), ranking #108 of 2,343 CEC inverters at 98.42% efficiency with a 750-900 V MPPT window and 900 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 49,763 W
- AC Voltage
- 480 V, 3-phase
- Min PV Breaker
- 80 A (4 AWG Cu)
- CEC Efficiency
- 98.42%
How Does Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} Compare Against Peer CEC Listings?
CEC efficiency rank (#108), 750-900 V MPPT tracking, and panel fit for Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V}.
Operating at 480 V, 3-phase, Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} converts DC array energy at 98.42% CEC weighted efficiency (top 4.9%; higher than 95.1% of peers) with a 900 V max DC input and 61.7335 A max input current for NEC 690.7 string safety. Compare this 49,763 W grid-tied PV inverter directly with Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} (49,800 W). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
Where Does Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} at 49,763 W continuous AC output.
What Dataset Percentiles Define Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V}?
Dataset percentiles comparing Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} against 2,343 certified grid-support inverters nationwide.
What Do the Dataset Ranks Show for Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V}?
Engineering highlights for Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} covering efficiency, 4 AWG Cu feeder, and panel compatibility.
98.42% CEC Weighted Efficiency
+0.40 pts vs the 98.02% 480 V median; overall power rank #464 (49,763 W, top 19.8%; higher than 80.2% of peers).
80 A Required Backfeed OCPD
125% x 59.9 A = 74.9 A -> 80 A standard OCPD using 4 AWG Cu (75 C).
750 V - 900 V (Max 900 V DC)
Tracking span of 150.0 V; active in CEC directory (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 49763.3W / 480 V 3-phase -> 59.9 A | Breaker >= 1.25 * 59.9 = 74.9 A -> 80 A
CEC Inverters.csv for Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V}: Paco=49763.3 W, Vac=480 V, Vdcmax=900.0 V, Eff=98.42%.
Result: Min 80 A breaker & 4 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V}?
California Energy Commission Solar Equipment List parameters for Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} (grid-tied PV inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 49,763 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 900 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 750 V - 900 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 61.7335 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 98.42% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} (480 V, 3-phase)?
Panelboard and switchgear backfeed allowances for Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} (80 A OCPD).
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (480V) | 40 A | 80 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (480V) | 80 A | 80 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (480V) | 120 A | 80 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (480V) | 160 A | 80 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (480V) | 240 A | 80 A | PASS (120% Commercial Busbar) |
Which Competing Grid-Support Inverters Compare to Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V}?
Four alternative CEC inverters matched to Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} (49,763 W AC), led by Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} Ginlong Technologies Co Ltd |
49,800 W | +37 W | 480.0 V | 850.0 V | 97.14% |
| Fortress Power LLC: FP-Nano-50k-N {480V} Fortress Power LLC |
49,803 W | +40 W | 480.0 V | 850.0 V | 97.41% |
| Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US(21A) {480V} Ginlong Technologies Co Ltd |
49,803 W | +40 W | 480.0 V | 850.0 V | 97.41% |
| CSI Solar Co Ltd: CSI-50K-T480GL03-U {480V} CSI Solar Co Ltd |
49,848 W | +85 W | 480.0 V | 850.0 V | 98.29% |
What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V}?
Check Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} (49,763 W AC, 80 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 900 V DC on Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V}.
Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} Panel & Wire Spec
Size 75 C copper conductors at 4 AWG Cu on an 80 A OCPD breaker (59.9 A continuous).
Alternative Inverter Comparison
Compare efficiency (98.42%) and MPPT window (750-900 V) directly against Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} (49,800 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} by Shenzhen Growatt New Energy Co Ltd covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.
What breaker and wire size does Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} require?
At 49,763 W continuous AC (480 V, 3-phase), continuous current is 59.9 A; 125% NEC 690.8/705.12 sizing requires an 80 A breaker and 4 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} require?
At 49,763 W AC and 480 V, 3-phase, continuous line current is 59.9 A, requiring an 80 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.
How does Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} compare to Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}?
Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V} delivers 49,763 W AC at 98.42% CEC efficiency with a 900 V DC ceiling, while Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} outputs 49,800 W at 480 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)