Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} outputs 3,095 W AC at 240 V (12.9 A continuous, 20 A OCPD), ranking #769 of 2,343 CEC inverters at 97.2% efficiency with a 125-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
3,095 W
AC Voltage
240 V
Min PV Breaker
20 A (12 AWG Cu)
CEC Efficiency
97.2%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} Compare Against Peer CEC Listings?

Breaker sizing (20 A), 12 AWG Cu wire rules, and DC input limits for Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V}.

For NEC 705.12 solar interconnection, Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} outputs 12.9 A continuous AC at 240 V and needs a 20 A backfeed breaker on 12 AWG Cu (75 C). Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Conversion efficiency scores 97.2% (#769 of 2,343, +0.38 pts vs overall CEC median).

Where Does Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} Fall Across Listed CEC Models?

Output power comparison showing where Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} (3,095 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACShenzhen Growatt N: 3,095 W

What Dataset Percentiles Define Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V}?

Relative ranking of Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} Technical ThresholdsPercentile comparison for Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output3,095 WCEC Efficiency97.2%Backfeed Breaker20 A

What Do the Dataset Ranks Show for Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V}?

Snapshot of Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} efficiency rank (#769), OCPD breaker size, MPPT span, and busbar verdict.

Eff #769 / 2,343

97.2% CEC Weighted Efficiency

+0.52 pts vs the 96.68% 240 V median; overall power rank #1,723 (3,095 W, below CEC median; higher than 26.4% of peers).

NEC 705.12 Check

20 A Required Backfeed OCPD

125% x 12.9 A = 16.1 A -> 20 A standard OCPD using 12 AWG Cu (75 C).

MPPT Window

125 V - 480 V (Max 480 V DC)

Tracking span of 355.0 V; listed since 2023-07-11 (hybrid battery-capable inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3095.0W / 240 V -> 12.9 A | Breaker >= 1.25 * 12.9 = 16.1 A -> 20 A

CEC Inverters.csv for Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V}: Paco=3095.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.2%.

Result: Min 20 A breaker & 12 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V}.

Official California Energy Commission (NREL SAM) test parameters for Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 3,095 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 125 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 8.37954 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.2% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2023-07-11 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} at 240 V.

Evaluates Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} (20 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 20 A PASS (120% Rule)
150A Bus / 150A Main 30 A 20 A PASS (120% Rule)
200A Bus / 200A Main 40 A 20 A PASS (120% Rule)
200A Bus / 175A Main 65 A 20 A PASS (120% Rule)
225A Bus / 200A Main 70 A 20 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V}?

Minimum and maximum series solar module strings fitting Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} MPPT and 480 V limits.

Sampled CEC PV modules aligned within 125.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 3 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 4 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 4 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 5 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V}?

Peer 240 V CEC inverters near 3,095 W AC output such as Base Power Inc: MIN 3000TL-XH-US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Base Power Inc: MIN 3000TL-XH-US {240V}
Base Power Inc
3,095 W Tie (0 W) 240.0 V 480.0 V 97.2%
ABB: PVI-30-OUTD-S-US-A {240V}
ABB
3,000 W -95 W 240.0 V 480.0 V 96.1%
ABB: PVI-30-OUTD-S-US-Z-A {240V}
ABB
3,000 W -95 W 240.0 V 480.0 V 96.1%
ABB: PVI-30-OUTD-S-US-Z-M-A {240V}
ABB
3,000 W -95 W 240.0 V 480.0 V 96.1%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V}?

Check Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} (3,095 W AC, 20 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V}.

Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 12 AWG Cu on a 20 A OCPD breaker (12.9 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.2%) and MPPT window (125-480 V) directly against Base Power Inc: MIN 3000TL-XH-US {240V} (3,095 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} by Shenzhen Growatt New Energy Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} require?

At 3,095 W continuous AC (240 V), continuous current is 12.9 A; 125% NEC 690.8/705.12 sizing requires a 20 A breaker and 12 AWG Cu (75 C) wire.

Does Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 20 A at 240 V means PASS (120% Rule).

How does Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} compare to Base Power Inc: MIN 3000TL-XH-US {240V}?

Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V} delivers 3,095 W AC at 97.2% CEC efficiency with a 480 V DC ceiling, while Base Power Inc: MIN 3000TL-XH-US {240V} outputs 3,095 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.