Manufacturer: Shenzhen Cubenergy Co Ltd Registry: CEC Verified Engineering Specification

Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} outputs 220,432 W AC at 690 V, 3-phase (184.4 A continuous, 250 A OCPD), ranking #532 of 2,343 CEC inverters at 97.54% efficiency with a 1,056-1,346 V MPPT window and 1,346 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
220,432 W
AC Voltage
690 V, 3-phase
Min PV Breaker
250 A (parallel Cu feeders)
CEC Efficiency
97.54%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 690 V, 3-phase grid-support overview for Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V}.

Rated at 220,432 W AC (184.4 A continuous), Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} ranks #532 of 2,343 CEC units at 97.54% efficiency (-0.63 pts vs the 98.17% 690 V median). Minimum 75 C copper conductor sizing for its 250 A circuit is parallel Cu feeders per NEC Table 310.16. Cold-weather string Voc must remain under 1,346 V DC at record local winter lows.

Where Does Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} Fall Across Listed CEC Models?

Marks Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} (220,432 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} (220,432 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACShenzhen Cubenergy: 220,432 W

What Dataset Percentiles Define Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V}?

Benchmarks Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} continuous AC output, 97.54% CEC weighted efficiency, and 250 A OCPD breaker demand.

Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} Technical ThresholdsPercentile comparison for Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output220,432 WCEC Efficiency97.54%Backfeed Breaker250 A

What Do the Dataset Ranks Show for Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V}?

Four key NEC 705.12 and California Energy Commission metrics defining Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} by Shenzhen Cubenergy Co Ltd.

Eff #532 / 2,343

97.54% CEC Weighted Efficiency

-0.63 pts vs the 98.17% 690 V median; overall power rank #240 (220,432 W, top 10.3%; higher than 89.7% of peers).

NEC 705.12 Check

250 A Required Backfeed OCPD

125% x 184.4 A = 230.5 A -> 250 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

1,056 V - 1,346 V (Max 1,346 V DC)

Tracking span of 290.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 690 V, 3-phase switchgear (200A Bus / 200A Main (690V) to 1,200A Bus / 1,200A Main (690V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 220432.0W / 690 V 3-phase -> 184.4 A | Breaker >= 1.25 * 184.4 = 230.5 A -> 250 A

CEC Inverters.csv for Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V}: Paco=220432.0 W, Vac=690 V, Vdcmax=1346.0 V, Eff=97.54%.

Result: Min 250 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (690V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V}.

Official California Energy Commission (NREL SAM) test parameters for Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 220,432 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 690 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,346 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 1,056 V - 1,346 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 188.49 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.54% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} (690 V, 3-phase)?

Evaluates Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} (250 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} (250 A required OCPD at 690 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (690V) 40 A 250 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (690V) 80 A 250 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (690V) 120 A 250 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (690V) 160 A 250 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (690V) 240 A 250 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which Competing Grid-Support Inverters Compare to Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V}?

Competing CEC grid-support inverters near 220,432 W AC and 690 V, 3-phase, led by SINENG ELECTRIC CO LTD: EH-0200-HA-M-US {690V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
SINENG ELECTRIC CO LTD: EH-0200-HA-M-US {690V}
SINENG ELECTRIC CO LTD
220,432 W Tie (0 W) 690.0 V 1346.0 V 97.54%
CSI Solar Co Ltd: CSEC-215K-T6901A-U {690V}
CSI Solar Co Ltd
215,937 W -4495 W 690.0 V 1500.0 V 98.38%
Sungrow Power Supply Co Ltd: SC210HX-US {690V}
Sungrow Power Supply Co Ltd
212,078 W -8354 W 690.0 V 1500.0 V 98.49%
SHENZHEN CLOU ELECTRONICS CO LTD: CL215HX-IEC/UL {690V}
SHENZHEN CLOU ELECTRONICS CO LTD
236,841 W +16409 W 690.0 V 1500.0 V 98.42%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V}?

Check Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} (220,432 W AC, 250 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,346 V DC on Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V}.

Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 250 A OCPD breaker (184.4 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.54%) and MPPT window (1,056-1,346 V) directly against SINENG ELECTRIC CO LTD: EH-0200-HA-M-US {690V} (220,432 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} by Shenzhen Cubenergy Co Ltd covering breaker sizing, MPPT limits, and 690 V, 3-phase interconnection.

What breaker and wire size does Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} require?

At 220,432 W continuous AC (690 V, 3-phase), continuous current is 184.4 A; 125% NEC 690.8/705.12 sizing requires a 250 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} require?

At 220,432 W AC and 690 V, 3-phase, continuous line current is 184.4 A, requiring a 250 A OCPD and 1,200A Bus / 1,200A Main (690V) or NEC 705.11 interconnection.

How does Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} compare to SINENG ELECTRIC CO LTD: EH-0200-HA-M-US {690V}?

Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V} delivers 220,432 W AC at 97.54% CEC efficiency with a 1,346 V DC ceiling, while SINENG ELECTRIC CO LTD: EH-0200-HA-M-US {690V} outputs 220,432 W at 690 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.