Savant Systems Inc: PS-INV-125KW-60A-XX {240V} outputs 12,411 W AC at 240 V (51.7 A continuous, 70 A OCPD), ranking #1,936 of 2,343 CEC inverters at 96.04% efficiency with a 250-530 V MPPT window and 530 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 12,411 W
- AC Voltage
- 240 V
- Min PV Breaker
- 70 A (4 AWG Cu)
- CEC Efficiency
- 96.04%
How Does Savant Systems Inc: PS-INV-125KW-60A-XX {240V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Savant Systems Inc: PS-INV-125KW-60A-XX {240V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Rated at 12,411 W AC (51.7 A continuous), Savant Systems Inc: PS-INV-125KW-60A-XX {240V} ranks #1,936 of 2,343 CEC units at 96.04% efficiency (-0.64 pts vs the 96.68% 240 V median). Minimum 75 C copper conductor sizing for its 70 A circuit is 4 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 530 V DC at record local winter lows.
Where Does Savant Systems Inc: PS-INV-125KW-60A-XX {240V} Fall Across Listed CEC Models?
Marks Savant Systems Inc: PS-INV-125KW-60A-XX {240V} (12,411 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define Savant Systems Inc: PS-INV-125KW-60A-XX {240V}?
Benchmarks Savant Systems Inc: PS-INV-125KW-60A-XX {240V} continuous AC output, 96.04% CEC weighted efficiency, and 70 A OCPD breaker demand.
What Do the Dataset Ranks Show for Savant Systems Inc: PS-INV-125KW-60A-XX {240V}?
Four key NEC 705.12 and California Energy Commission metrics defining Savant Systems Inc: PS-INV-125KW-60A-XX {240V} by Savant Systems Inc.
96.04% CEC Weighted Efficiency
-0.64 pts vs the 96.68% 240 V median; overall power rank #702 (12,411 W, top 30.0%; higher than 70.0% of peers).
70 A Required Backfeed OCPD
125% x 51.7 A = 64.6 A -> 70 A standard OCPD using 4 AWG Cu (75 C).
250 V - 530 V (Max 530 V DC)
Tracking span of 280.0 V; listed since 2023-01-11 (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 12410.9W / 240 V -> 51.7 A | Breaker >= 1.25 * 51.7 = 64.6 A -> 70 A
CEC Inverters.csv for Savant Systems Inc: PS-INV-125KW-60A-XX {240V}: Paco=12410.9 W, Vac=240 V, Vdcmax=530.0 V, Eff=96.04%.
Result: Min 70 A breaker & 4 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for Savant Systems Inc: PS-INV-125KW-60A-XX {240V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Savant Systems Inc: PS-INV-125KW-60A-XX {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 12,411 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 530 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 250 V - 530 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 35.8982 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.04% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2023-01-11 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for Savant Systems Inc: PS-INV-125KW-60A-XX {240V}?
Evaluates Savant Systems Inc: PS-INV-125KW-60A-XX {240V} (70 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 70 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 70 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 70 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 70 A | Needs Derate / Tap 705.11 |
| 225A Bus / 200A Main | 70 A | 70 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Savant Systems Inc: PS-INV-125KW-60A-XX {240V}?
Sample PV string lengths aligned within 250-530 V MPPT and 530 V DC max at -10 C. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 6 to 9 panels | 5.31 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 8 to 12 panels | 5.28 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 8 to 11 panels | 4.67 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 9 to 13 panels | 2.6 kW |
Which Competing Grid-Support Inverters Compare to Savant Systems Inc: PS-INV-125KW-60A-XX {240V}?
Competing CEC grid-support inverters near 12,411 W AC and 240 V, led by Amensolar Ess Co Ltd: N3H-X12US {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Amensolar Ess Co Ltd: N3H-X12US {240V} Amensolar Ess Co Ltd |
12,214 W | -197 W | 240.0 V | 430.0 V | 96.17% |
| Chint Power Systems America: CPS ECH12KTL/US {240V} Chint Power Systems America |
11,990 W | -421 W | 240.0 V | 480.0 V | 96.59% |
| Delta Electronics: S12_BDI {240V} Delta Electronics |
11,589 W | -822 W | 240.0 V | 480.0 V | 96.99% |
| Base Power Inc: MIN 11400TL-XH-US {240V} Base Power Inc |
11,520 W | -891 W | 240.0 V | 480.0 V | 97.76% |
What Are the Interconnection Limits and Best-Fit Uses for Savant Systems Inc: PS-INV-125KW-60A-XX {240V}?
Check Savant Systems Inc: PS-INV-125KW-60A-XX {240V} (12,411 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 70 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 530 V DC on Savant Systems Inc: PS-INV-125KW-60A-XX {240V}.
Savant Systems Inc: PS-INV-125KW-60A-XX {240V} Panel & Wire Spec
Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (51.7 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.04%) and MPPT window (250-530 V) directly against Amensolar Ess Co Ltd: N3H-X12US {240V} (12,214 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Savant Systems Inc: PS-INV-125KW-60A-XX {240V} by Savant Systems Inc covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Savant Systems Inc: PS-INV-125KW-60A-XX {240V} require?
At 12,411 W continuous AC (240 V), continuous current is 51.7 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.
Does Savant Systems Inc: PS-INV-125KW-60A-XX {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 70 A at 240 V means Needs Derate / Tap 705.11.
How does Savant Systems Inc: PS-INV-125KW-60A-XX {240V} compare to Amensolar Ess Co Ltd: N3H-X12US {240V}?
Savant Systems Inc: PS-INV-125KW-60A-XX {240V} delivers 12,411 W AC at 96.04% CEC efficiency with a 530 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X12US {240V} outputs 12,214 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)