Savant Systems Inc: PS-INV-125KW-100A-XX {240V} — CEC Inverter Specifications

Manufacturer: Savant Systems Inc Registry: CEC Verified Engineering Specification

Savant Systems Inc: PS-INV-125KW-100A-XX {240V} outputs 12,411 W AC at 240 V (51.7 A continuous, 70 A OCPD), ranking #1,936 of 2,343 CEC inverters at 96.04% efficiency with a 250-530 V MPPT window and 530 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
12,411 W
AC Voltage
240 V
Min PV Breaker
70 A (4 AWG Cu)
CEC Efficiency
96.04%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Savant Systems Inc: PS-INV-125KW-100A-XX {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,936), 250-530 V MPPT tracking, and panel fit for Savant Systems Inc: PS-INV-125KW-100A-XX {240V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Savant Systems Inc: PS-INV-125KW-100A-XX {240V} from Savant Systems Inc outputs 51.7 A continuous AC at 240 V (12,411 W AC, rank #702). Paired with 4 AWG Cu conductors and a 70 A OCPD, its 96.04% CEC efficiency compares closely with Amensolar Ess Co Ltd: N3H-X12US {240V} (12,214 W). Keep NEC 690.7 winter string Voc below 530 V DC.

Where Does Savant Systems Inc: PS-INV-125KW-100A-XX {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Savant Systems Inc: PS-INV-125KW-100A-XX {240V} at 12,411 W continuous AC output. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Savant Systems Inc: PS-INV-125KW-100A-XX {240V} (12,411 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSavant Systems Inc: 12,411 W

What Dataset Percentiles Define Savant Systems Inc: PS-INV-125KW-100A-XX {240V}?

Dataset percentiles comparing Savant Systems Inc: PS-INV-125KW-100A-XX {240V} against 2,343 certified grid-support inverters nationwide. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Savant Systems Inc: PS-INV-125KW-100A-XX {240V} Technical ThresholdsPercentile comparison for Savant Systems Inc: PS-INV-125KW-100A-XX {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output12,411 WCEC Efficiency96.04%Backfeed Breaker70 A

What Do the Dataset Ranks Show for Savant Systems Inc: PS-INV-125KW-100A-XX {240V}?

Engineering highlights for Savant Systems Inc: PS-INV-125KW-100A-XX {240V} covering efficiency, 4 AWG Cu feeder, and panel compatibility. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Eff #1,936 / 2,343

96.04% CEC Weighted Efficiency

-0.64 pts vs the 96.68% 240 V median; overall power rank #702 (12,411 W, top 30.0%; higher than 70.0% of peers).

NEC 705.12 Check

70 A Required Backfeed OCPD

125% x 51.7 A = 64.6 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

250 V - 530 V (Max 530 V DC)

Tracking span of 280.0 V; listed since 2024-12-23 (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 12410.9W / 240 V -> 51.7 A | Breaker >= 1.25 * 51.7 = 64.6 A -> 70 A

CEC Inverters.csv for Savant Systems Inc: PS-INV-125KW-100A-XX {240V}: Paco=12410.9 W, Vac=240 V, Vdcmax=530.0 V, Eff=96.04%.

Result: Min 70 A breaker & 4 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Savant Systems Inc: PS-INV-125KW-100A-XX {240V}?

California Energy Commission Solar Equipment List parameters for Savant Systems Inc: PS-INV-125KW-100A-XX {240V} (hybrid battery-capable inverter) interconnection. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for Savant Systems Inc: PS-INV-125KW-100A-XX {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 12,411 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 530 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 250 V - 530 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 35.8982 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.04% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2024-12-23 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Savant Systems Inc: PS-INV-125KW-100A-XX {240V}?

Panelboard and switchgear backfeed allowances for Savant Systems Inc: PS-INV-125KW-100A-XX {240V} (70 A OCPD). Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Evaluates Savant Systems Inc: PS-INV-125KW-100A-XX {240V} (70 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 70 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 70 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 70 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 70 A Needs Derate / Tap 705.11
225A Bus / 200A Main 70 A 70 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Savant Systems Inc: PS-INV-125KW-100A-XX {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Savant Systems Inc: PS-INV-125KW-100A-XX {240V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sampled CEC PV modules aligned within 250.0-530.0 V MPPT and 530.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 6 to 9 panels 5.31 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 8 to 12 panels 5.28 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 8 to 11 panels 4.67 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 9 to 13 panels 2.6 kW

Which Competing Grid-Support Inverters Compare to Savant Systems Inc: PS-INV-125KW-100A-XX {240V}?

Four alternative CEC inverters matched to Savant Systems Inc: PS-INV-125KW-100A-XX {240V} (12,411 W AC), led by Amensolar Ess Co Ltd: N3H-X12US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Amensolar Ess Co Ltd: N3H-X12US {240V}
Amensolar Ess Co Ltd
12,214 W -197 W 240.0 V 430.0 V 96.17%
Chint Power Systems America: CPS ECH12KTL/US {240V}
Chint Power Systems America
11,990 W -421 W 240.0 V 480.0 V 96.59%
Delta Electronics: S12_BDI {240V}
Delta Electronics
11,589 W -822 W 240.0 V 480.0 V 96.99%
Base Power Inc: MIN 11400TL-XH-US {240V}
Base Power Inc
11,520 W -891 W 240.0 V 480.0 V 97.76%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Savant Systems Inc: PS-INV-125KW-100A-XX {240V}?

Check Savant Systems Inc: PS-INV-125KW-100A-XX {240V} (12,411 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 70 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 530 V DC on Savant Systems Inc: PS-INV-125KW-100A-XX {240V}.

Savant Systems Inc: PS-INV-125KW-100A-XX {240V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (51.7 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.04%) and MPPT window (250-530 V) directly against Amensolar Ess Co Ltd: N3H-X12US {240V} (12,214 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Savant Systems Inc: PS-INV-125KW-100A-XX {240V} by Savant Systems Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Savant Systems Inc: PS-INV-125KW-100A-XX {240V} require?

At 12,411 W continuous AC (240 V), continuous current is 51.7 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

Does Savant Systems Inc: PS-INV-125KW-100A-XX {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 70 A at 240 V means Needs Derate / Tap 705.11.

How does Savant Systems Inc: PS-INV-125KW-100A-XX {240V} compare to Amensolar Ess Co Ltd: N3H-X12US {240V}?

Savant Systems Inc: PS-INV-125KW-100A-XX {240V} delivers 12,411 W AC at 96.04% CEC efficiency with a 530 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X12US {240V} outputs 12,214 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.