Manufacturer: Power Electronics Registry: CEC Verified Engineering Specification

Power Electronics: FS3000M {34000V} outputs 3,109,266 W AC at 34,500 V, 3-phase (52.0 A continuous, 70 A OCPD), ranking #689 of 2,343 CEC inverters at 97.29% efficiency with a 849-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
3,109,266 W
AC Voltage
34,500 V, 3-phase
Min PV Breaker
70 A (4 AWG Cu)
CEC Efficiency
97.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Power Electronics: FS3000M {34000V} Compare Against Peer CEC Listings?

How Power Electronics Power Electronics: FS3000M {34000V} compares on 97.29% efficiency, MPPT span, and 120% busbar interconnection. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

With a 849-1,200 V MPPT tracking band and 1,200 V DC ceiling, Power Electronics: FS3000M {34000V} handles 3,109,266 W continuous AC (228,387 W below the 3,337,653 W 34,500 V median). Commercial 34,500 V, 3-phase switchgear interconnection uses 5.0 MVA Utility Substation or NEC 705.11 supply-side tap. Installers comparing Power Electronics against Sungrow Power Supply Co Ltd: SG3150U {630V} (3,154,300 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.

Where Does Power Electronics: FS3000M {34000V} Fall Across Listed CEC Models?

Position of Power Electronics: FS3000M {34000V} (3,109,266 W AC) relative to the 7,680 W CEC median inverter. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Power Electronics: FS3000M {34000V} (3,109,266 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACPower Electronics:: 3,109,266 W

What Dataset Percentiles Define Power Electronics: FS3000M {34000V}?

Percentile placement of Power Electronics: FS3000M {34000V} across AC power class, conversion efficiency, and backfeed breaker size. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Power Electronics: FS3000M {34000V} Technical ThresholdsPercentile comparison for Power Electronics: FS3000M {34000V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output3,109,266 WCEC Efficiency97.29%Backfeed Breaker70 A

What Do the Dataset Ranks Show for Power Electronics: FS3000M {34000V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Power Electronics: FS3000M {34000V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Eff #689 / 2,343

97.29% CEC Weighted Efficiency

-0.12 pts vs the 97.41% 34,500 V median; overall power rank #50 (3,109,266 W, top 2.1%; higher than 97.9% of peers).

NEC 705.12 Check

70 A Required Backfeed OCPD

125% x 52.0 A = 65.0 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

849 V - 1,200 V (Max 1,200 V DC)

Tracking span of 351.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Medium-Voltage Utility Skid (NEC 705.11 / IEEE 1547)

Evaluated for 34,500 V, 3-phase switchgear (1.0 MVA MV Step-Up to 5.0 MVA Utility Substation) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3109266.0W / 34,500 V 3-phase -> 52.0 A | Breaker >= 1.25 * 52.0 = 65.0 A -> 70 A

CEC Inverters.csv for Power Electronics: FS3000M {34000V}: Paco=3109266.0 W, Vac=34500 V, Vdcmax=1200.0 V, Eff=97.29%.

Result: Min 70 A breaker & 4 AWG Cu (75 C); 5.0 MVA Utility Substation: Medium-Voltage Utility Skid (NEC 705.11 / IEEE 1547).

What Are the Published CEC Specifications for Power Electronics: FS3000M {34000V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Power Electronics: FS3000M {34000V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Power Electronics: FS3000M {34000V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 3,109,266 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 34,500 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 849 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 3399.88 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.29% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Power Electronics: FS3000M {34000V} (34,500 V, 3-phase)?

Check whether Power Electronics: FS3000M {34000V} (70 A breaker) fits without main breaker derate or supply-side taps. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Evaluates Power Electronics: FS3000M {34000V} (70 A required OCPD at 34,500 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
1.0 MVA MV Step-Up Utility MV Interconnect 70 A @ 34,500V Medium-Voltage Utility Skid (NEC 705.11 / IEEE 1547)
2.5 MVA MV Step-Up Utility MV Interconnect 70 A @ 34,500V Medium-Voltage Utility Skid (NEC 705.11 / IEEE 1547)
5.0 MVA Utility Substation Utility MV Interconnect 70 A @ 34,500V Medium-Voltage Utility Skid (NEC 705.11 / IEEE 1547)

Which CEC PV Module Strings Pair With Power Electronics: FS3000M {34000V}?

Verified cold-weather (-10 C) series module counts matched to Power Electronics: FS3000M {34000V}'s 1,200 V DC ceiling.

Sampled CEC PV modules aligned within 849.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 20 to 21 panels 12.39 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 26 to 28 panels 12.32 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 25 to 26 panels 11.05 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 21 to 22 panels 11.33 kW

Which Competing Grid-Support Inverters Compare to Power Electronics: FS3000M {34000V}?

Alternative CEC inverters comparable to Power Electronics: FS3000M {34000V}, including Sungrow Power Supply Co Ltd: SG3150U {630V} (3,154,300 W) at 34,500 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Sungrow Power Supply Co Ltd: SG3150U {630V}
Sungrow Power Supply Co Ltd
3,154,300 W +45034 W 630.0 V 1300.0 V 97.49%
INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V}
INGETEAM POWER TECHNOLOGY SA
2,467,620 W -641646 W 480.0 V 1300.0 V 96.63%
SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}
SINENG ELECTRIC CO LTD
1,726,700 W -1382566 W 690.0 V 1500.0 V 98.32%
Schneider Electric USA Inc: CS1666-3-NA {575V}
Schneider Electric USA Inc
1,666,000 W -1443266 W 575.0 V 1200.0 V 97.54%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Power Electronics: FS3000M {34000V}?

Check Power Electronics: FS3000M {34000V} (3,109,266 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 34,500 V, 3-phase switchgear interconnection uses 5.0 MVA Utility Substation or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on Power Electronics: FS3000M {34000V}.

Power Electronics: FS3000M {34000V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (52.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.29%) and MPPT window (849-1,200 V) directly against Sungrow Power Supply Co Ltd: SG3150U {630V} (3,154,300 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Power Electronics: FS3000M {34000V} by Power Electronics covering breaker sizing, MPPT limits, and 34,500 V, 3-phase interconnection.

What breaker and wire size does Power Electronics: FS3000M {34000V} require?

At 3,109,266 W continuous AC (34,500 V, 3-phase), continuous current is 52.0 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Power Electronics: FS3000M {34000V} require?

At 3,109,266 W AC and 34,500 V, 3-phase, continuous line current is 52.0 A, requiring a 70 A OCPD and 5.0 MVA Utility Substation or NEC 705.11 interconnection.

How does Power Electronics: FS3000M {34000V} compare to Sungrow Power Supply Co Ltd: SG3150U {630V}?

Power Electronics: FS3000M {34000V} delivers 3,109,266 W AC at 97.29% CEC efficiency with a 1,200 V DC ceiling, while Sungrow Power Supply Co Ltd: SG3150U {630V} outputs 3,154,300 W at 34,500 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.