Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Power Electronics: FS2180K {615V} — CEC Inverter Specifications

Manufacturer: Power Electronics Registry: CEC Verified Engineering Specification

Power Electronics: FS2180K {615V} outputs 2,259,500 W AC at 615 V, 3-phase (2121.2 A continuous, 2,700 A OCPD), ranking #318 of 2,343 CEC inverters at 98.05% efficiency with a 870-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
2,259,500 W
AC Voltage
615 V, 3-phase
Min PV Breaker
2,700 A (parallel Cu feeders)
CEC Efficiency
98.05%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Power Electronics: FS2180K {615V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 615 V, 3-phase grid-support overview for Power Electronics: FS2180K {615V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Ranking #91 of 2,343 CEC inverters (top 3.9%; higher than 96.1% of peers), Power Electronics: FS2180K {615V} is a grid-tied PV inverter delivering 2,259,500 W continuous AC at 615 V, 3-phase (2121.2 A continuous). Commercial 615 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (615V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 98.05% (+0.40 pts vs the 97.65% 615 V median) against peers like INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V} (2,467,620 W).

Where Does Power Electronics: FS2180K {615V} Fall Across Listed CEC Models?

Marks Power Electronics: FS2180K {615V} (2,259,500 W AC) across the California Energy Commission inverter AC capacity distribution. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Power Electronics: FS2180K {615V} (2,259,500 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACPower Electronics:: 2,259,500 W

What Dataset Percentiles Define Power Electronics: FS2180K {615V}?

Benchmarks Power Electronics: FS2180K {615V} continuous AC output, 98.05% CEC weighted efficiency, and 2,700 A OCPD breaker demand.

Power Electronics: FS2180K {615V} Technical ThresholdsPercentile comparison for Power Electronics: FS2180K {615V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output2,259,500 WCEC Efficiency98.05%Backfeed Breaker2,700 A

What Do the Dataset Ranks Show for Power Electronics: FS2180K {615V}?

Four key NEC 705.12 and California Energy Commission metrics defining Power Electronics: FS2180K {615V} by Power Electronics. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Eff #318 / 2,343

98.05% CEC Weighted Efficiency

+0.40 pts vs the 97.65% 615 V median; overall power rank #91 (2,259,500 W, top 3.9%; higher than 96.1% of peers).

NEC 705.12 Check

2,700 A Required Backfeed OCPD

125% x 2121.2 A = 2651.5 A -> 2,700 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

870 V - 1,200 V (Max 1,200 V DC)

Tracking span of 330.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 615 V, 3-phase switchgear (200A Bus / 200A Main (615V) to 1,200A Bus / 1,200A Main (615V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 2259500.0W / 615 V 3-phase -> 2121.2 A | Breaker >= 1.25 * 2121.2 = 2651.5 A -> 2,700 A

CEC Inverters.csv for Power Electronics: FS2180K {615V}: Paco=2259500.0 W, Vac=615 V, Vdcmax=1200.0 V, Eff=98.05%.

Result: Min 2,700 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (615V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for Power Electronics: FS2180K {615V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Power Electronics: FS2180K {615V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Power Electronics: FS2180K {615V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 2,259,500 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 615 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 870 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 2425.71 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.05% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Power Electronics: FS2180K {615V} (615 V, 3-phase)?

Evaluates Power Electronics: FS2180K {615V} (2,700 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Power Electronics: FS2180K {615V} (2700 A required OCPD at 615 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (615V) 40 A 2,700 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (615V) 80 A 2,700 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (615V) 120 A 2,700 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (615V) 160 A 2,700 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (615V) 240 A 2,700 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With Power Electronics: FS2180K {615V}?

Sample PV string lengths aligned within 870-1,200 V MPPT and 1,200 V DC max at -10 C. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sampled CEC PV modules aligned within 870.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 21 panels (fixed) 12.39 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 26 to 28 panels 12.32 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 26 panels (fixed) 11.05 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 22 panels (fixed) 11.33 kW

Which Competing Grid-Support Inverters Compare to Power Electronics: FS2180K {615V}?

Competing CEC grid-support inverters near 2,259,500 W AC and 615 V, 3-phase, led by INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V}
INGETEAM POWER TECHNOLOGY SA
2,467,620 W +208120 W 480.0 V 1300.0 V 96.63%
SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}
SINENG ELECTRIC CO LTD
1,726,700 W -532800 W 690.0 V 1500.0 V 98.32%
Schneider Electric USA Inc: CS1666-3-NA {575V}
Schneider Electric USA Inc
1,666,000 W -593500 W 575.0 V 1200.0 V 97.54%
Sungrow Power Supply Co Ltd: SG3150U {630V}
Sungrow Power Supply Co Ltd
3,154,300 W +894800 W 630.0 V 1300.0 V 97.49%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Power Electronics: FS2180K {615V}?

Check Power Electronics: FS2180K {615V} (2,259,500 W AC, 2,700 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 615 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (615V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on Power Electronics: FS2180K {615V}.

Power Electronics: FS2180K {615V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 2,700 A OCPD breaker (2121.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.05%) and MPPT window (870-1,200 V) directly against INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V} (2,467,620 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Power Electronics: FS2180K {615V} by Power Electronics covering breaker sizing, MPPT limits, and 615 V, 3-phase interconnection.

What breaker and wire size does Power Electronics: FS2180K {615V} require?

At 2,259,500 W continuous AC (615 V, 3-phase), continuous current is 2121.2 A; 125% NEC 690.8/705.12 sizing requires a 2,700 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does Power Electronics: FS2180K {615V} require?

At 2,259,500 W AC and 615 V, 3-phase, continuous line current is 2121.2 A, requiring a 2,700 A OCPD and 1,200A Bus / 1,200A Main (615V) or NEC 705.11 interconnection.

How does Power Electronics: FS2180K {615V} compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V}?

Power Electronics: FS2180K {615V} delivers 2,259,500 W AC at 98.05% CEC efficiency with a 1,200 V DC ceiling, while INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V} outputs 2,467,620 W at 615 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.