Power Electronics: FS2000M {34000V} outputs 2,178,068 W AC at 34,500 V, 3-phase (36.5 A continuous, 50 A OCPD), ranking #546 of 2,343 CEC inverters at 97.51% efficiency with a 849-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 2,178,068 W
- AC Voltage
- 34,500 V, 3-phase
- Min PV Breaker
- 50 A (8 AWG Cu)
- CEC Efficiency
- 97.51%
How Does Power Electronics: FS2000M {34000V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 34,500 V, 3-phase grid-support overview for Power Electronics: FS2000M {34000V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
Rated at 2,178,068 W AC (36.5 A continuous), Power Electronics: FS2000M {34000V} ranks #546 of 2,343 CEC units at 97.51% efficiency (+0.10 pts vs the 97.41% 34,500 V median). Minimum 75 C copper conductor sizing for its 50 A circuit is 8 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 1,200 V DC at record local winter lows.
Where Does Power Electronics: FS2000M {34000V} Fall Across Listed CEC Models?
Marks Power Electronics: FS2000M {34000V} (2,178,068 W AC) across the California Energy Commission inverter AC capacity distribution. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Dataset Percentiles Define Power Electronics: FS2000M {34000V}?
Benchmarks Power Electronics: FS2000M {34000V} continuous AC output, 97.51% CEC weighted efficiency, and 50 A OCPD breaker demand.
What Do the Dataset Ranks Show for Power Electronics: FS2000M {34000V}?
Four key NEC 705.12 and California Energy Commission metrics defining Power Electronics: FS2000M {34000V} by Power Electronics. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
97.51% CEC Weighted Efficiency
+0.10 pts vs the 97.41% 34,500 V median; overall power rank #95 (2,178,068 W, top 4.1%; higher than 95.9% of peers).
50 A Required Backfeed OCPD
125% x 36.5 A = 45.6 A -> 50 A standard OCPD using 8 AWG Cu (75 C).
849 V - 1,200 V (Max 1,200 V DC)
Tracking span of 351.0 V; active in CEC directory (grid-tied PV inverter).
Medium-Voltage Utility Skid (NEC 705.11 / IEEE 1547)
Evaluated for 34,500 V, 3-phase switchgear (1.0 MVA MV Step-Up to 5.0 MVA Utility Substation) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 2178068.0W / 34,500 V 3-phase -> 36.5 A | Breaker >= 1.25 * 36.5 = 45.6 A -> 50 A
CEC Inverters.csv for Power Electronics: FS2000M {34000V}: Paco=2178068.0 W, Vac=34500 V, Vdcmax=1200.0 V, Eff=97.51%.
Result: Min 50 A breaker & 8 AWG Cu (75 C); 5.0 MVA Utility Substation: Medium-Voltage Utility Skid (NEC 705.11 / IEEE 1547).
What Are the Published CEC Specifications for Power Electronics: FS2000M {34000V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Power Electronics: FS2000M {34000V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 2,178,068 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 34,500 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,200 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 849 V - 1,200 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 2376.36 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.51% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to Power Electronics: FS2000M {34000V} (34,500 V, 3-phase)?
Evaluates Power Electronics: FS2000M {34000V} (50 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 1.0 MVA MV Step-Up | Utility MV Interconnect | 50 A @ 34,500V | Medium-Voltage Utility Skid (NEC 705.11 / IEEE 1547) |
| 2.5 MVA MV Step-Up | Utility MV Interconnect | 50 A @ 34,500V | Medium-Voltage Utility Skid (NEC 705.11 / IEEE 1547) |
| 5.0 MVA Utility Substation | Utility MV Interconnect | 50 A @ 34,500V | Medium-Voltage Utility Skid (NEC 705.11 / IEEE 1547) |
Which CEC PV Module Strings Pair With Power Electronics: FS2000M {34000V}?
Sample PV string lengths aligned within 849-1,200 V MPPT and 1,200 V DC max at -10 C. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 20 to 21 panels | 12.39 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 26 to 28 panels | 12.32 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 25 to 26 panels | 11.05 kW |
| Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 | 515.0 W | 53.76 V | 21 to 22 panels | 11.33 kW |
Which Competing Grid-Support Inverters Compare to Power Electronics: FS2000M {34000V}?
Competing CEC grid-support inverters near 2,178,068 W AC and 34,500 V, 3-phase, led by INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V} INGETEAM POWER TECHNOLOGY SA |
2,467,620 W | +289552 W | 480.0 V | 1300.0 V | 96.63% |
| SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V} SINENG ELECTRIC CO LTD |
1,726,700 W | -451368 W | 690.0 V | 1500.0 V | 98.32% |
| Schneider Electric USA Inc: CS1666-3-NA {575V} Schneider Electric USA Inc |
1,666,000 W | -512068 W | 575.0 V | 1200.0 V | 97.54% |
| Sungrow Power Supply Co Ltd: SG3150U {630V} Sungrow Power Supply Co Ltd |
3,154,300 W | +976232 W | 630.0 V | 1300.0 V | 97.49% |
What Are the Interconnection Limits and Best-Fit Uses for Power Electronics: FS2000M {34000V}?
Check Power Electronics: FS2000M {34000V} (2,178,068 W AC, 50 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 34,500 V, 3-phase switchgear interconnection uses 5.0 MVA Utility Substation or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on Power Electronics: FS2000M {34000V}.
Power Electronics: FS2000M {34000V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 50 A OCPD breaker (36.5 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.51%) and MPPT window (849-1,200 V) directly against INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V} (2,467,620 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Power Electronics: FS2000M {34000V} by Power Electronics covering breaker sizing, MPPT limits, and 34,500 V, 3-phase interconnection.
What breaker and wire size does Power Electronics: FS2000M {34000V} require?
At 2,178,068 W continuous AC (34,500 V, 3-phase), continuous current is 36.5 A; 125% NEC 690.8/705.12 sizing requires a 50 A breaker and 8 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Power Electronics: FS2000M {34000V} require?
At 2,178,068 W AC and 34,500 V, 3-phase, continuous line current is 36.5 A, requiring a 50 A OCPD and 5.0 MVA Utility Substation or NEC 705.11 interconnection.
How does Power Electronics: FS2000M {34000V} compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V}?
Power Electronics: FS2000M {34000V} delivers 2,178,068 W AC at 97.51% CEC efficiency with a 1,200 V DC ceiling, while INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V} outputs 2,467,620 W at 34,500 V, 3-phase.