Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Power Electronics: FS1400CU15 {565V} — CEC Inverter Specifications

Manufacturer: Power Electronics Registry: CEC Verified Engineering Specification

Power Electronics: FS1400CU15 {565V} outputs 1,517,090 W AC at 565 V, 3-phase (1550.3 A continuous, 1,950 A OCPD), ranking #526 of 2,343 CEC inverters at 97.56% efficiency with a 800-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
1,517,090 W
AC Voltage
565 V, 3-phase
Min PV Breaker
1,950 A (parallel Cu feeders)
CEC Efficiency
97.56%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Power Electronics: FS1400CU15 {565V} Compare Against Peer CEC Listings?

How Power Electronics Power Electronics: FS1400CU15 {565V} compares on 97.56% efficiency, MPPT span, and 120% busbar interconnection. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Power Electronics certifies Power Electronics: FS1400CU15 {565V} (grid-tied PV inverter, listed since 2018-10-15) at 1,517,090 W AC (379,440 W below the 1,896,530 W 565 V median). Its 1,200 V DC ceiling pairs with an MPPT window of 800-1,200 V (span 400.0 V). Under NEC 690.8/705.12, 125% sizing demands parallel Cu feeders conductors on a 1,950 A OCPD.

Where Does Power Electronics: FS1400CU15 {565V} Fall Across Listed CEC Models?

Position of Power Electronics: FS1400CU15 {565V} (1,517,090 W AC) relative to the 7,680 W CEC median inverter. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Power Electronics: FS1400CU15 {565V} (1,517,090 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACPower Electronics:: 1,517,090 W

What Dataset Percentiles Define Power Electronics: FS1400CU15 {565V}?

Percentile placement of Power Electronics: FS1400CU15 {565V} across AC power class, conversion efficiency, and backfeed breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Power Electronics: FS1400CU15 {565V} Technical ThresholdsPercentile comparison for Power Electronics: FS1400CU15 {565V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output1,517,090 WCEC Efficiency97.56%Backfeed Breaker1,950 A

What Do the Dataset Ranks Show for Power Electronics: FS1400CU15 {565V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Power Electronics: FS1400CU15 {565V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Eff #526 / 2,343

97.56% CEC Weighted Efficiency

-0.08 pts vs the 97.64% 565 V median; overall power rank #130 (1,517,090 W, top 5.5%; higher than 94.5% of peers).

NEC 705.12 Check

1,950 A Required Backfeed OCPD

125% x 1550.3 A = 1937.9 A -> 1,950 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

800 V - 1,200 V (Max 1,200 V DC)

Tracking span of 400.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 565 V, 3-phase switchgear (200A Bus / 200A Main (565V) to 1,200A Bus / 1,200A Main (565V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1517090.0W / 565 V 3-phase -> 1550.3 A | Breaker >= 1.25 * 1550.3 = 1937.9 A -> 1,950 A

CEC Inverters.csv for Power Electronics: FS1400CU15 {565V}: Paco=1517090.0 W, Vac=565 V, Vdcmax=1200.0 V, Eff=97.56%.

Result: Min 1,950 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (565V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for Power Electronics: FS1400CU15 {565V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Power Electronics: FS1400CU15 {565V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for Power Electronics: FS1400CU15 {565V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 1,517,090 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 565 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 800 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1727.9 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.56% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2018-10-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Power Electronics: FS1400CU15 {565V} (565 V, 3-phase)?

Check whether Power Electronics: FS1400CU15 {565V} (1,950 A breaker) fits without main breaker derate or supply-side taps. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Evaluates Power Electronics: FS1400CU15 {565V} (1950 A required OCPD at 565 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (565V) 40 A 1,950 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (565V) 80 A 1,950 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (565V) 120 A 1,950 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (565V) 160 A 1,950 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (565V) 240 A 1,950 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With Power Electronics: FS1400CU15 {565V}?

Verified cold-weather (-10 C) series module counts matched to Power Electronics: FS1400CU15 {565V}'s 1,200 V DC ceiling.

Sampled CEC PV modules aligned within 800.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 19 to 21 panels 12.39 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 24 to 28 panels 12.32 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 24 to 26 panels 11.05 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 28 to 29 panels 5.8 kW

Which Competing Grid-Support Inverters Compare to Power Electronics: FS1400CU15 {565V}?

Alternative CEC inverters comparable to Power Electronics: FS1400CU15 {565V}, including Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W) at 565 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Schneider Electric USA Inc: CS1666-3-NA {575V}
Schneider Electric USA Inc
1,666,000 W +148910 W 575.0 V 1200.0 V 97.54%
SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}
SINENG ELECTRIC CO LTD
1,726,700 W +209610 W 690.0 V 1500.0 V 98.32%
INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V}
INGETEAM POWER TECHNOLOGY SA
2,467,620 W +950530 W 480.0 V 1300.0 V 96.63%
EPC Power Corp: 50-200100 {720V}
EPC Power Corp
561,806 W -955284 W 720.0 V 1500.0 V 98.58%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Power Electronics: FS1400CU15 {565V}?

Check Power Electronics: FS1400CU15 {565V} (1,517,090 W AC, 1,950 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 565 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (565V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on Power Electronics: FS1400CU15 {565V}.

Power Electronics: FS1400CU15 {565V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,950 A OCPD breaker (1550.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.56%) and MPPT window (800-1,200 V) directly against Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Power Electronics: FS1400CU15 {565V} by Power Electronics covering breaker sizing, MPPT limits, and 565 V, 3-phase interconnection.

What breaker and wire size does Power Electronics: FS1400CU15 {565V} require?

At 1,517,090 W continuous AC (565 V, 3-phase), continuous current is 1550.3 A; 125% NEC 690.8/705.12 sizing requires a 1,950 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does Power Electronics: FS1400CU15 {565V} require?

At 1,517,090 W AC and 565 V, 3-phase, continuous line current is 1550.3 A, requiring a 1,950 A OCPD and 1,200A Bus / 1,200A Main (565V) or NEC 705.11 interconnection.

How does Power Electronics: FS1400CU15 {565V} compare to Schneider Electric USA Inc: CS1666-3-NA {575V}?

Power Electronics: FS1400CU15 {565V} delivers 1,517,090 W AC at 97.56% CEC efficiency with a 1,200 V DC ceiling, while Schneider Electric USA Inc: CS1666-3-NA {575V} outputs 1,666,000 W at 565 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.