Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} — CEC Inverter Specifications

Manufacturer: Oxford Intelligent Energy Co Ltd Registry: CEC Verified Engineering Specification

Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} outputs 10,140 W AC at 240 V (42.2 A continuous, 60 A OCPD), ranking #1,467 of 2,343 CEC inverters at 96.56% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
10,140 W
AC Voltage
240 V
Min PV Breaker
60 A (6 AWG Cu)
CEC Efficiency
96.56%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,467), 200-480 V MPPT tracking, and panel fit for Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V}.

Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} from Oxford Intelligent Energy Co Ltd outputs 42.2 A continuous AC at 240 V (10,140 W AC, rank #855). Paired with 6 AWG Cu conductors and a 60 A OCPD, its 96.56% CEC efficiency compares closely with Amensolar Ess Co Ltd: N3H-X100-US {240V} (10,177 W). Keep NEC 690.7 winter string Voc below 480 V DC.

Where Does Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} at 10,140 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} (10,140 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACOxford Intelligent: 10,140 W

What Dataset Percentiles Define Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V}?

Dataset percentiles comparing Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} against 2,343 certified grid-support inverters nationwide.

Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} Technical ThresholdsPercentile comparison for Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output10,140 WCEC Efficiency96.56%Backfeed Breaker60 A

What Do the Dataset Ranks Show for Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V}?

Engineering highlights for Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} covering efficiency, 6 AWG Cu feeder, and panel compatibility.

Eff #1,467 / 2,343

96.56% CEC Weighted Efficiency

-0.12 pts vs the 96.68% 240 V median; overall power rank #855 (10,140 W, top 36.7%; higher than 63.3% of peers).

NEC 705.12 Check

60 A Required Backfeed OCPD

125% x 42.2 A = 52.8 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

200 V - 480 V (Max 480 V DC)

Tracking span of 280.0 V; listed since 2026-05-21 (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 10140.0W / 240 V -> 42.2 A | Breaker >= 1.25 * 42.2 = 52.8 A -> 60 A

CEC Inverters.csv for Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V}: Paco=10140.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.56%.

Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V}?

California Energy Commission Solar Equipment List parameters for Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} (hybrid battery-capable inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 10,140 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 200 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 29.1709 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.56% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2026-05-21 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V}?

Panelboard and switchgear backfeed allowances for Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} (60 A OCPD).

Evaluates Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} (60 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 60 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 60 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 60 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 60 A PASS (120% Rule)
225A Bus / 200A Main 70 A 60 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V}.

Sampled CEC PV modules aligned within 200.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V}?

Four alternative CEC inverters matched to Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} (10,140 W AC), led by Amensolar Ess Co Ltd: N3H-X100-US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Amensolar Ess Co Ltd: N3H-X100-US {240V}
Amensolar Ess Co Ltd
10,177 W +37 W 240.0 V 430.0 V 97.15%
Amensolar Ess Co Ltd: N3H-X10US {240V}
Amensolar Ess Co Ltd
10,177 W +37 W 240.0 V 430.0 V 97.15%
Base Power Inc: MIN 10000TL-XH-US {240V}
Base Power Inc
10,082 W -58 W 240.0 V 480.0 V 97.61%
Delta Electronics: E10_BDI {240V}
Delta Electronics
9,674 W -466 W 240.0 V 480.0 V 97.21%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V}?

Check Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} (10,140 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V}.

Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (42.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.56%) and MPPT window (200-480 V) directly against Amensolar Ess Co Ltd: N3H-X100-US {240V} (10,177 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} by Oxford Intelligent Energy Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} require?

At 10,140 W continuous AC (240 V), continuous current is 42.2 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

Does Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.

How does Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} compare to Amensolar Ess Co Ltd: N3H-X100-US {240V}?

Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V} delivers 10,140 W AC at 96.56% CEC efficiency with a 480 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X100-US {240V} outputs 10,177 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.