Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} outputs 10,147 W AC at 240 V (42.3 A continuous, 60 A OCPD), ranking #1,467 of 2,343 CEC inverters at 96.56% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 10,147 W
- AC Voltage
- 240 V
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 96.56%
How Does Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} Compare Against Peer CEC Listings?
Breaker sizing (60 A), 6 AWG Cu wire rules, and DC input limits for Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V}.
For NEC 705.12 solar interconnection, Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} outputs 42.3 A continuous AC at 240 V and needs a 60 A backfeed breaker on 6 AWG Cu (75 C). Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Conversion efficiency scores 96.56% (#1,467 of 2,343, -0.26 pts vs overall CEC median).
Where Does Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} Fall Across Listed CEC Models?
Output power comparison showing where Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} sits among all 2,343 CEC-listed grid-support inverters.
What Dataset Percentiles Define Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V}?
Relative ranking of Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.
What Do the Dataset Ranks Show for Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V}?
Snapshot of Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} efficiency rank (#1,467), OCPD breaker size, MPPT span, and busbar verdict.
96.56% CEC Weighted Efficiency
-0.12 pts vs the 96.68% 240 V median; overall power rank #852 (10,147 W, top 36.4%; higher than 63.6% of peers).
60 A Required Backfeed OCPD
125% x 42.3 A = 52.9 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
200 V - 480 V (Max 480 V DC)
Tracking span of 280.0 V; listed since 2026-05-21 (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 10147.0W / 240 V -> 42.3 A | Breaker >= 1.25 * 42.3 = 52.9 A -> 60 A
CEC Inverters.csv for Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V}: Paco=10147.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.56%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V}?
Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 10,147 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 200 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 29.1916 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.56% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2026-05-21 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V}?
NEC 705.12(B)(3)(2) backfeed compliance table for Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} at 240 V.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 60 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 60 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 60 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V}?
Minimum and maximum series solar module strings fitting Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} MPPT and 480 V limits.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 5 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 6 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 6 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 7 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V}?
Peer 240 V CEC inverters near 10,147 W AC output such as Amensolar Ess Co Ltd: N3H-X100-US {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Amensolar Ess Co Ltd: N3H-X100-US {240V} Amensolar Ess Co Ltd |
10,177 W | +30 W | 240.0 V | 430.0 V | 97.15% |
| Amensolar Ess Co Ltd: N3H-X10US {240V} Amensolar Ess Co Ltd |
10,177 W | +30 W | 240.0 V | 430.0 V | 97.15% |
| Base Power Inc: MIN 10000TL-XH-US {240V} Base Power Inc |
10,082 W | -65 W | 240.0 V | 480.0 V | 97.61% |
| Delta Electronics: E10_BDI {240V} Delta Electronics |
9,674 W | -473 W | 240.0 V | 480.0 V | 97.21% |
What Are the Interconnection Limits and Best-Fit Uses for Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V}?
Check Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} (10,147 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V}.
Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (42.3 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.56%) and MPPT window (200-480 V) directly against Amensolar Ess Co Ltd: N3H-X100-US {240V} (10,177 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} by Oxford Intelligent Energy Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} require?
At 10,147 W continuous AC (240 V), continuous current is 42.3 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
Does Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.
How does Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} compare to Amensolar Ess Co Ltd: N3H-X100-US {240V}?
Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V} delivers 10,147 W AC at 96.56% CEC efficiency with a 480 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X100-US {240V} outputs 10,177 W at 240 V.