Northern Electric & Power Co Ltd: Neptune36K {480V} outputs 35,866 W AC at 480 V, 3-phase (43.1 A continuous, 60 A OCPD), ranking #238 of 2,343 CEC inverters at 98.21% efficiency with a 580-850 V MPPT window and 850 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 35,866 W
- AC Voltage
- 480 V, 3-phase
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 98.21%
How Does Northern Electric & Power Co Ltd: Neptune36K {480V} Compare Against Peer CEC Listings?
How Northern Electric & Power Co Ltd Northern Electric & Power Co Ltd: Neptune36K {480V} compares on 98.21% efficiency, MPPT span, and 120% busbar interconnection.
Northern Electric & Power Co Ltd certifies Northern Electric & Power Co Ltd: Neptune36K {480V} (grid-tied PV inverter, active in CEC directory) at 35,866 W AC (14,134 W below the 50,000 W 480 V median). Its 850 V DC ceiling pairs with an MPPT window of 580-850 V (span 270.0 V). Under NEC 690.8/705.12, 125% sizing demands 6 AWG Cu conductors on a 60 A OCPD.
Where Does Northern Electric & Power Co Ltd: Neptune36K {480V} Fall Across Listed CEC Models?
Position of Northern Electric & Power Co Ltd: Neptune36K {480V} (35,866 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define Northern Electric & Power Co Ltd: Neptune36K {480V}?
Percentile placement of Northern Electric & Power Co Ltd: Neptune36K {480V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for Northern Electric & Power Co Ltd: Neptune36K {480V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Northern Electric & Power Co Ltd: Neptune36K {480V}.
98.21% CEC Weighted Efficiency
+0.19 pts vs the 98.02% 480 V median; overall power rank #523 (35,866 W, top 22.4%; higher than 77.6% of peers).
60 A Required Backfeed OCPD
125% x 43.1 A = 53.9 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
580 V - 850 V (Max 850 V DC)
Tracking span of 270.0 V; active in CEC directory (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 35866.0W / 480 V 3-phase -> 43.1 A | Breaker >= 1.25 * 43.1 = 53.9 A -> 60 A
CEC Inverters.csv for Northern Electric & Power Co Ltd: Neptune36K {480V}: Paco=35866.0 W, Vac=480 V, Vdcmax=850.0 V, Eff=98.21%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Northern Electric & Power Co Ltd: Neptune36K {480V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Northern Electric & Power Co Ltd: Neptune36K {480V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 35,866 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 850 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 580 V - 850 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 50.7234 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 98.21% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to Northern Electric & Power Co Ltd: Neptune36K {480V} (480 V, 3-phase)?
Check whether Northern Electric & Power Co Ltd: Neptune36K {480V} (60 A breaker) fits without main breaker derate or supply-side taps.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (480V) | 40 A | 60 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (480V) | 80 A | 60 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (480V) | 120 A | 60 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (480V) | 160 A | 60 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (480V) | 240 A | 60 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Northern Electric & Power Co Ltd: Neptune36K {480V}?
Verified cold-weather (-10 C) series module counts matched to Northern Electric & Power Co Ltd: Neptune36K {480V}'s 850 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 14 to 15 panels | 8.85 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 18 to 20 panels | 8.8 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 17 to 18 panels | 7.65 kW |
| Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 | 515.0 W | 53.76 V | 15 panels (fixed) | 7.72 kW |
Which Competing Grid-Support Inverters Compare to Northern Electric & Power Co Ltd: Neptune36K {480V}?
Alternative CEC inverters comparable to Northern Electric & Power Co Ltd: Neptune36K {480V}, including CSI Solar Co Ltd: CSI-36K-T480GL03-U {480V} (35,866 W) at 480 V, 3-phase.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| CSI Solar Co Ltd: CSI-36K-T480GL03-U {480V} CSI Solar Co Ltd |
35,866 W | Tie (0 W) | 480.0 V | 850.0 V | 98.21% |
| CSI Solar Co Ltd: CSI-36K-T480GL01-UB {480V} CSI Solar Co Ltd |
35,925 W | +59 W | 480.0 V | 800.0 V | 98.32% |
| Canadian Solar Inc: CSI-36KTL-CT {480V} Canadian Solar Inc |
36,000 W | +134 W | 480.0 V | 800.0 V | 98.09% |
| Canadian Solar Inc: CSI-36KTL-GS-FL {480V} Canadian Solar Inc |
36,000 W | +134 W | 480.0 V | 780.0 V | 98.05% |
What Are the Interconnection Limits and Best-Fit Uses for Northern Electric & Power Co Ltd: Neptune36K {480V}?
Check Northern Electric & Power Co Ltd: Neptune36K {480V} (35,866 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 850 V DC on Northern Electric & Power Co Ltd: Neptune36K {480V}.
Northern Electric & Power Co Ltd: Neptune36K {480V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (43.1 A continuous).
Alternative Inverter Comparison
Compare efficiency (98.21%) and MPPT window (580-850 V) directly against CSI Solar Co Ltd: CSI-36K-T480GL03-U {480V} (35,866 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Northern Electric & Power Co Ltd: Neptune36K {480V} by Northern Electric & Power Co Ltd covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.
What breaker and wire size does Northern Electric & Power Co Ltd: Neptune36K {480V} require?
At 35,866 W continuous AC (480 V, 3-phase), continuous current is 43.1 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Northern Electric & Power Co Ltd: Neptune36K {480V} require?
At 35,866 W AC and 480 V, 3-phase, continuous line current is 43.1 A, requiring a 60 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.
How does Northern Electric & Power Co Ltd: Neptune36K {480V} compare to CSI Solar Co Ltd: CSI-36K-T480GL03-U {480V}?
Northern Electric & Power Co Ltd: Neptune36K {480V} delivers 35,866 W AC at 98.21% CEC efficiency with a 850 V DC ceiling, while CSI Solar Co Ltd: CSI-36K-T480GL03-U {480V} outputs 35,866 W at 480 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)