Northern Electric & Power Co Ltd: BDM-800-208A {208V} outputs 707 W AC at 208 V, commercial single-phase (3.4 A continuous, 15 A OCPD), ranking #1,732 of 2,343 CEC inverters at 96.33% efficiency with a 22-55 V MPPT window and 55 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 707 W
- AC Voltage
- 208 V, commercial single-phase
- Min PV Breaker
- 15 A (14 AWG Cu)
- CEC Efficiency
- 96.33%
How Does Northern Electric & Power Co Ltd: BDM-800-208A {208V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 208 V, commercial single-phase grid-support overview for Northern Electric & Power Co Ltd: BDM-800-208A {208V}.
Rated at 707 W AC (3.4 A continuous), Northern Electric & Power Co Ltd: BDM-800-208A {208V} ranks #1,732 of 2,343 CEC units at 96.33% efficiency (-0.08 pts vs the 96.41% 208 V median). Minimum 75 C copper conductor sizing for its 15 A circuit is 14 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 55 V DC at record local winter lows.
Where Does Northern Electric & Power Co Ltd: BDM-800-208A {208V} Fall Across Listed CEC Models?
Marks Northern Electric & Power Co Ltd: BDM-800-208A {208V} (707 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define Northern Electric & Power Co Ltd: BDM-800-208A {208V}?
Benchmarks Northern Electric & Power Co Ltd: BDM-800-208A {208V} continuous AC output, 96.33% CEC weighted efficiency, and 15 A OCPD breaker demand.
What Do the Dataset Ranks Show for Northern Electric & Power Co Ltd: BDM-800-208A {208V}?
Four key NEC 705.12 and California Energy Commission metrics defining Northern Electric & Power Co Ltd: BDM-800-208A {208V} by Northern Electric & Power Co Ltd.
96.33% CEC Weighted Efficiency
-0.08 pts vs the 96.41% 208 V median; overall power rank #1,904 (707 W, below CEC median; higher than 18.7% of peers).
15 A Required Backfeed OCPD
125% x 3.4 A = 4.2 A -> 15 A standard OCPD using 14 AWG Cu (75 C).
22 V - 55 V (Max 55 V DC)
Tracking span of 33.0 V; listed since 2025-11-12 (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 707.0W / 208 V -> 3.4 A | Breaker >= 1.25 * 3.4 = 4.2 A -> 15 A
CEC Inverters.csv for Northern Electric & Power Co Ltd: BDM-800-208A {208V}: Paco=707.0 W, Vac=208 V, Vdcmax=55.0 V, Eff=96.33%.
Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Northern Electric & Power Co Ltd: BDM-800-208A {208V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Northern Electric & Power Co Ltd: BDM-800-208A {208V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 707 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 55 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 22 V - 55 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 20.9696 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.33% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2025-11-12 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Northern Electric & Power Co Ltd: BDM-800-208A {208V} (208 V, commercial single-phase)?
Evaluates Northern Electric & Power Co Ltd: BDM-800-208A {208V} (15 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 15 A | PASS (120% Commercial Busbar) |
| 400A Bus / 400A Main (208V) | 80 A | 15 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 15 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 15 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 15 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Northern Electric & Power Co Ltd: BDM-800-208A {208V}?
Sample PV string lengths aligned within 22-55 V MPPT and 55 V DC max at -10 C. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 | 515.0 W | 53.76 V | 1 panel (micro/module) | 0.52 kW |
Which Competing Grid-Support Inverters Compare to Northern Electric & Power Co Ltd: BDM-800-208A {208V}?
Competing CEC grid-support inverters near 707 W AC and 208 V, commercial single-phase, led by Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} Chilicon Power LLC |
725 W | +18 W | 208.0 V | 70.0 V | 94.81% |
| Aptos Solar Technology LLC: MAC-800 {208V} Aptos Solar Technology LLC |
767 W | +60 W | 208.0 V | 48.0 V | 96.12% |
| Aptos Solar Technology LLC: MAC-800R {208V} Aptos Solar Technology LLC |
767 W | +60 W | 208.0 V | 48.0 V | 96.12% |
| Enphase Energy Inc: IQ8D-72-E-US {208V} Enphase Energy Inc |
640 W | -67 W | 208.0 V | 95.0 V | 97.09% |
What Are the Interconnection Limits and Best-Fit Uses for Northern Electric & Power Co Ltd: BDM-800-208A {208V}?
Check Northern Electric & Power Co Ltd: BDM-800-208A {208V} (707 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 55 V DC on Northern Electric & Power Co Ltd: BDM-800-208A {208V}.
Northern Electric & Power Co Ltd: BDM-800-208A {208V} Panel & Wire Spec
Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (3.4 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.33%) and MPPT window (22-55 V) directly against Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} (725 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Northern Electric & Power Co Ltd: BDM-800-208A {208V} by Northern Electric & Power Co Ltd covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.
What breaker and wire size does Northern Electric & Power Co Ltd: BDM-800-208A {208V} require?
At 707 W continuous AC (208 V, commercial single-phase), continuous current is 3.4 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Northern Electric & Power Co Ltd: BDM-800-208A {208V} require?
At 707 W AC and 208 V, commercial single-phase, continuous line current is 3.4 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does Northern Electric & Power Co Ltd: BDM-800-208A {208V} compare to Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V}?
Northern Electric & Power Co Ltd: BDM-800-208A {208V} delivers 707 W AC at 96.33% CEC efficiency with a 55 V DC ceiling, while Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} outputs 725 W at 208 V, commercial single-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)