Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} — CEC Inverter Specifications

Manufacturer: Northern Electric & Power Co Ltd Registry: CEC Verified Engineering Specification

Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} outputs 590 W AC at 208 V, commercial single-phase (2.8 A continuous, 15 A OCPD), ranking #1,785 of 2,343 CEC inverters at 96.28% efficiency with a 22-55 V MPPT window and 55 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
590 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
96.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} Compare Against Peer CEC Listings?

How Northern Electric & Power Co Ltd Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} compares on 96.28% efficiency, MPPT span, and 120% busbar interconnection.

Northern Electric & Power Co Ltd certifies Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} (grid-tied PV inverter, listed since 2025-11-12) at 590 W AC (4,410 W below the 5,000 W 208 V median). Its 55 V DC ceiling pairs with an MPPT window of 22-55 V (span 33.0 V). Under NEC 690.8/705.12, 125% sizing demands 14 AWG Cu conductors on a 15 A OCPD.

Where Does Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} Fall Across Listed CEC Models?

Position of Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} (590 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} (590 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACNorthern Electric : 590 W

What Dataset Percentiles Define Northern Electric & Power Co Ltd: BDM-300X2-208A {208V}?

Percentile placement of Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} across AC power class, conversion efficiency, and backfeed breaker size.

Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} Technical ThresholdsPercentile comparison for Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output590 WCEC Efficiency96.28%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Northern Electric & Power Co Ltd: BDM-300X2-208A {208V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Northern Electric & Power Co Ltd: BDM-300X2-208A {208V}.

Eff #1,785 / 2,343

96.28% CEC Weighted Efficiency

-0.13 pts vs the 96.41% 208 V median; overall power rank #1,935 (590 W, below CEC median; higher than 17.4% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 2.8 A = 3.5 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

22 V - 55 V (Max 55 V DC)

Tracking span of 33.0 V; listed since 2025-11-12 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 590.0W / 208 V -> 2.8 A | Breaker >= 1.25 * 2.8 = 3.5 A -> 15 A

CEC Inverters.csv for Northern Electric & Power Co Ltd: BDM-300X2-208A {208V}: Paco=590.0 W, Vac=208 V, Vdcmax=55.0 V, Eff=96.28%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Northern Electric & Power Co Ltd: BDM-300X2-208A {208V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Northern Electric & Power Co Ltd: BDM-300X2-208A {208V}.

Official California Energy Commission (NREL SAM) test parameters for Northern Electric & Power Co Ltd: BDM-300X2-208A {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 590 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 55 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 22 V - 55 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 17.5081 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.28% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-11-12 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} (208 V, commercial single-phase)?

Check whether Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} (15 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} (15 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 15 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 15 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 15 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 15 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 15 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Northern Electric & Power Co Ltd: BDM-300X2-208A {208V}?

Verified cold-weather (-10 C) series module counts matched to Northern Electric & Power Co Ltd: BDM-300X2-208A {208V}'s 55 V DC ceiling.

Sampled CEC PV modules aligned within 22.0-55.0 V MPPT and 55.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 1 panel (micro/module) 0.52 kW

Which Competing Grid-Support Inverters Compare to Northern Electric & Power Co Ltd: BDM-300X2-208A {208V}?

Alternative CEC inverters comparable to Northern Electric & Power Co Ltd: BDM-300X2-208A {208V}, including Cherry Solution Co Ltd: CMI-600S-SA {208V} (608 W) at 208 V, commercial single-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Cherry Solution Co Ltd: CMI-600S-SA {208V}
Cherry Solution Co Ltd
608 W +18 W 208.0 V 50.0 V 96.49%
Cherry Solution Co Ltd: CMI-600S-WA {208V}
Cherry Solution Co Ltd
608 W +18 W 208.0 V 50.0 V 96.49%
Enphase Energy Inc: IQ8D-BAT {208V}
Enphase Energy Inc
555 W -35 W 208.0 V 87.0 V 97.1%
Enphase Energy Inc: IQ8D-BAT-DOM {208V}
Enphase Energy Inc
555 W -35 W 208.0 V 87.0 V 97.1%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Northern Electric & Power Co Ltd: BDM-300X2-208A {208V}?

Check Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} (590 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 55 V DC on Northern Electric & Power Co Ltd: BDM-300X2-208A {208V}.

Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (2.8 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.28%) and MPPT window (22-55 V) directly against Cherry Solution Co Ltd: CMI-600S-SA {208V} (608 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} by Northern Electric & Power Co Ltd covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} require?

At 590 W continuous AC (208 V, commercial single-phase), continuous current is 2.8 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} require?

At 590 W AC and 208 V, commercial single-phase, continuous line current is 2.8 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} compare to Cherry Solution Co Ltd: CMI-600S-SA {208V}?

Northern Electric & Power Co Ltd: BDM-300X2-208A {208V} delivers 590 W AC at 96.28% CEC efficiency with a 55 V DC ceiling, while Cherry Solution Co Ltd: CMI-600S-SA {208V} outputs 608 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.