Cherry Solution Co Ltd: CMI-600S-WA {208V} outputs 608 W AC at 208 V, commercial single-phase (2.9 A continuous, 15 A OCPD), ranking #1,571 of 2,343 CEC inverters at 96.49% efficiency with a 35-50 V MPPT window and 50 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 608 W
- AC Voltage
- 208 V, commercial single-phase
- Min PV Breaker
- 15 A (14 AWG Cu)
- CEC Efficiency
- 96.49%
How Does Cherry Solution Co Ltd: CMI-600S-WA {208V} Compare Against Peer CEC Listings?
How Cherry Solution Co Ltd Cherry Solution Co Ltd: CMI-600S-WA {208V} compares on 96.49% efficiency, MPPT span, and 120% busbar interconnection.
With a 35-50 V MPPT tracking band and 50 V DC ceiling, Cherry Solution Co Ltd: CMI-600S-WA {208V} handles 608 W continuous AC (4,392 W below the 5,000 W 208 V median). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit. Installers comparing Cherry Solution Co Ltd against Enphase Energy Inc: IQ8D-72-E-US {208V} (640 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.
Where Does Cherry Solution Co Ltd: CMI-600S-WA {208V} Fall Across Listed CEC Models?
Position of Cherry Solution Co Ltd: CMI-600S-WA {208V} (608 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define Cherry Solution Co Ltd: CMI-600S-WA {208V}?
Percentile placement of Cherry Solution Co Ltd: CMI-600S-WA {208V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for Cherry Solution Co Ltd: CMI-600S-WA {208V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Cherry Solution Co Ltd: CMI-600S-WA {208V}.
96.49% CEC Weighted Efficiency
+0.08 pts vs the 96.41% 208 V median; overall power rank #1,922 (608 W, below CEC median; higher than 17.9% of peers).
15 A Required Backfeed OCPD
125% x 2.9 A = 3.6 A -> 15 A standard OCPD using 14 AWG Cu (75 C).
35 V - 50 V (Max 50 V DC)
Tracking span of 15.0 V; active in CEC directory (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 608.0W / 208 V -> 2.9 A | Breaker >= 1.25 * 2.9 = 3.6 A -> 15 A
CEC Inverters.csv for Cherry Solution Co Ltd: CMI-600S-WA {208V}: Paco=608.0 W, Vac=208 V, Vdcmax=50.0 V, Eff=96.49%.
Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Cherry Solution Co Ltd: CMI-600S-WA {208V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Cherry Solution Co Ltd: CMI-600S-WA {208V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 608 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 50 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 35 V - 50 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 15.0022 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.49% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to Cherry Solution Co Ltd: CMI-600S-WA {208V} (208 V, commercial single-phase)?
Check whether Cherry Solution Co Ltd: CMI-600S-WA {208V} (15 A breaker) fits without main breaker derate or supply-side taps.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 15 A | PASS (120% Commercial Busbar) |
| 400A Bus / 400A Main (208V) | 80 A | 15 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 15 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 15 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 15 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Cherry Solution Co Ltd: CMI-600S-WA {208V}?
Verified cold-weather (-10 C) series module counts matched to Cherry Solution Co Ltd: CMI-600S-WA {208V}'s 50 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW | 270.0 W | 42.56 V | 1 panel (micro/module) | 0.27 kW |
Which Competing Grid-Support Inverters Compare to Cherry Solution Co Ltd: CMI-600S-WA {208V}?
Alternative CEC inverters comparable to Cherry Solution Co Ltd: CMI-600S-WA {208V}, including Enphase Energy Inc: IQ8D-72-E-US {208V} (640 W) at 208 V, commercial single-phase.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Enphase Energy Inc: IQ8D-72-E-US {208V} Enphase Energy Inc |
640 W | +32 W | 208.0 V | 95.0 V | 97.09% |
| Enphase Energy Inc: IQ8D-BAT {208V} Enphase Energy Inc |
555 W | -53 W | 208.0 V | 87.0 V | 97.1% |
| Enphase Energy Inc: IQ8D-BAT-DOM {208V} Enphase Energy Inc |
555 W | -53 W | 208.0 V | 87.0 V | 97.1% |
| Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} Chilicon Power LLC |
725 W | +117 W | 208.0 V | 70.0 V | 94.81% |
What Are the Interconnection Limits and Best-Fit Uses for Cherry Solution Co Ltd: CMI-600S-WA {208V}?
Check Cherry Solution Co Ltd: CMI-600S-WA {208V} (608 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 50 V DC on Cherry Solution Co Ltd: CMI-600S-WA {208V}.
Cherry Solution Co Ltd: CMI-600S-WA {208V} Panel & Wire Spec
Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (2.9 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.49%) and MPPT window (35-50 V) directly against Enphase Energy Inc: IQ8D-72-E-US {208V} (640 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Cherry Solution Co Ltd: CMI-600S-WA {208V} by Cherry Solution Co Ltd covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.
What breaker and wire size does Cherry Solution Co Ltd: CMI-600S-WA {208V} require?
At 608 W continuous AC (208 V, commercial single-phase), continuous current is 2.9 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Cherry Solution Co Ltd: CMI-600S-WA {208V} require?
At 608 W AC and 208 V, commercial single-phase, continuous line current is 2.9 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does Cherry Solution Co Ltd: CMI-600S-WA {208V} compare to Enphase Energy Inc: IQ8D-72-E-US {208V}?
Cherry Solution Co Ltd: CMI-600S-WA {208V} delivers 608 W AC at 96.49% CEC efficiency with a 50 V DC ceiling, while Enphase Energy Inc: IQ8D-72-E-US {208V} outputs 640 W at 208 V, commercial single-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)