Northern Electric & Power Co Ltd: BDM-2000-240A {240V} outputs 1,998 W AC at 240 V (8.3 A continuous, 15 A OCPD), ranking #1,669 of 2,343 CEC inverters at 96.4% efficiency with a 22-55 V MPPT window and 55 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 1,998 W
- AC Voltage
- 240 V
- Min PV Breaker
- 15 A (14 AWG Cu)
- CEC Efficiency
- 96.4%
How Does Northern Electric & Power Co Ltd: BDM-2000-240A {240V} Compare Against Peer CEC Listings?
Breaker sizing (15 A), 14 AWG Cu wire rules, and DC input limits for Northern Electric & Power Co Ltd: BDM-2000-240A {240V}.
Classified as a grid-tied PV inverter (listed since 2025-11-12), Northern Electric & Power Co Ltd: BDM-2000-240A {240V} requires 10.4 A design capacity -> 15 A breaker using 14 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 96.4% (-0.42 pts vs overall CEC median) across 2,343 CEC models, while requires a 15 a breaker, passing directly inside a standard 200 a main / 200 a busbar panel (40 a limit).
Where Does Northern Electric & Power Co Ltd: BDM-2000-240A {240V} Fall Across Listed CEC Models?
Output power comparison showing where Northern Electric & Power Co Ltd: BDM-2000-240A {240V} sits among all 2,343 CEC-listed grid-support inverters.
What Dataset Percentiles Define Northern Electric & Power Co Ltd: BDM-2000-240A {240V}?
Relative ranking of Northern Electric & Power Co Ltd: BDM-2000-240A {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.
What Do the Dataset Ranks Show for Northern Electric & Power Co Ltd: BDM-2000-240A {240V}?
Snapshot of Northern Electric & Power Co Ltd: BDM-2000-240A {240V} efficiency rank (#1,669), OCPD breaker size, MPPT span, and busbar verdict.
96.4% CEC Weighted Efficiency
-0.28 pts vs the 96.68% 240 V median; overall power rank #1,760 (1,998 W, below CEC median; higher than 24.9% of peers).
15 A Required Backfeed OCPD
125% x 8.3 A = 10.4 A -> 15 A standard OCPD using 14 AWG Cu (75 C).
22 V - 55 V (Max 55 V DC)
Tracking span of 33.0 V; listed since 2025-11-12 (grid-tied PV inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 1998.0W / 240 V -> 8.3 A | Breaker >= 1.25 * 8.3 = 10.4 A -> 15 A
CEC Inverters.csv for Northern Electric & Power Co Ltd: BDM-2000-240A {240V}: Paco=1998.0 W, Vac=240 V, Vdcmax=55.0 V, Eff=96.4%.
Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for Northern Electric & Power Co Ltd: BDM-2000-240A {240V}?
Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Northern Electric & Power Co Ltd: BDM-2000-240A {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 1,998 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 55 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 22 V - 55 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 59.2144 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.4% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2025-11-12 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for Northern Electric & Power Co Ltd: BDM-2000-240A {240V}?
NEC 705.12(B)(3)(2) backfeed compliance table for Northern Electric & Power Co Ltd: BDM-2000-240A {240V} at 240 V.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 15 A | PASS (120% Rule) |
| 150A Bus / 150A Main | 30 A | 15 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 15 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 15 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 15 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Northern Electric & Power Co Ltd: BDM-2000-240A {240V}?
Minimum and maximum series solar module strings fitting Northern Electric & Power Co Ltd: BDM-2000-240A {240V} MPPT and 55 V limits.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 | 515.0 W | 53.76 V | 1 panel (micro/module) | 0.52 kW |
Which Competing Grid-Support Inverters Compare to Northern Electric & Power Co Ltd: BDM-2000-240A {240V}?
Peer 240 V CEC inverters near 1,998 W AC output such as Altenergy Power System Inc: QS2 {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Altenergy Power System Inc: QS2 {240V} Altenergy Power System Inc |
1,924 W | -74 W | 240.0 V | 45.0 V | 95.22% |
| Altenergy Power System Inc: QS1A {240V} Altenergy Power System Inc |
1,516 W | -482 W | 240.0 V | 52.0 V | 95.75% |
| Altenergy Power System Inc: QS1 {240V} Altenergy Power System Inc |
1,225 W | -773 W | 240.0 V | 48.0 V | 96.02% |
| Altenergy Power System Inc: QS1200 {240V} Altenergy Power System Inc |
1,225 W | -773 W | 240.0 V | 48.0 V | 96.02% |
What Are the Interconnection Limits and Best-Fit Uses for Northern Electric & Power Co Ltd: BDM-2000-240A {240V}?
Check Northern Electric & Power Co Ltd: BDM-2000-240A {240V} (1,998 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 15 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 55 V DC on Northern Electric & Power Co Ltd: BDM-2000-240A {240V}.
Northern Electric & Power Co Ltd: BDM-2000-240A {240V} Panel & Wire Spec
Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (8.3 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.4%) and MPPT window (22-55 V) directly against Altenergy Power System Inc: QS2 {240V} (1,924 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Northern Electric & Power Co Ltd: BDM-2000-240A {240V} by Northern Electric & Power Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Northern Electric & Power Co Ltd: BDM-2000-240A {240V} require?
At 1,998 W continuous AC (240 V), continuous current is 8.3 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.
Does Northern Electric & Power Co Ltd: BDM-2000-240A {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).
How does Northern Electric & Power Co Ltd: BDM-2000-240A {240V} compare to Altenergy Power System Inc: QS2 {240V}?
Northern Electric & Power Co Ltd: BDM-2000-240A {240V} delivers 1,998 W AC at 96.4% CEC efficiency with a 55 V DC ceiling, while Altenergy Power System Inc: QS2 {240V} outputs 1,924 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)