INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} outputs 1,300,644 W AC at 690 V, 3-phase (1088.3 A continuous, 1,400 A OCPD), ranking #663 of 2,343 CEC inverters at 97.34% efficiency with a 962-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 1,300,644 W
- AC Voltage
- 690 V, 3-phase
- Min PV Breaker
- 1,400 A (parallel Cu feeders)
- CEC Efficiency
- 97.34%
How Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} Compare Against Peer CEC Listings?
How INGETEAM POWER TECHNOLOGY SA INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} compares on 97.34% efficiency, MPPT span, and 120% busbar interconnection.
INGETEAM POWER TECHNOLOGY SA certifies INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} (hybrid battery-capable inverter, active in CEC directory) at 1,300,644 W AC (439,314 W below the 1,739,958 W 690 V median). Its 1,200 V DC ceiling pairs with an MPPT window of 962-1,200 V (span 238.0 V). Under NEC 690.8/705.12, 125% sizing demands parallel Cu feeders conductors on a 1,400 A OCPD.
Where Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} Fall Across Listed CEC Models?
Position of INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} (1,300,644 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V}?
Percentile placement of INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V}.
97.34% CEC Weighted Efficiency
-0.83 pts vs the 98.17% 690 V median; overall power rank #143 (1,300,644 W, top 6.1%; higher than 93.9% of peers).
1,400 A Required Backfeed OCPD
125% x 1088.3 A = 1360.4 A -> 1,400 A standard OCPD using parallel Cu feeders (75 C).
962 V - 1,200 V (Max 1,200 V DC)
Tracking span of 238.0 V; active in CEC directory (hybrid battery-capable inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 690 V, 3-phase switchgear (200A Bus / 200A Main (690V) to 1,200A Bus / 1,200A Main (690V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 1300644.0W / 690 V 3-phase -> 1088.3 A | Breaker >= 1.25 * 1088.3 = 1360.4 A -> 1,400 A
CEC Inverters.csv for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V}: Paco=1300644.0 W, Vac=690 V, Vdcmax=1200.0 V, Eff=97.34%.
Result: Min 1,400 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (690V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 1,300,644 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 690 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,200 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 962 V - 1,200 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 1236.09 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.34% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} (690 V, 3-phase)?
Check whether INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} (1,400 A breaker) fits without main breaker derate or supply-side taps.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (690V) | 40 A | 1,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (690V) | 80 A | 1,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (690V) | 120 A | 1,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (690V) | 160 A | 1,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (690V) | 240 A | 1,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which Competing Grid-Support Inverters Compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V}?
Alternative CEC inverters comparable to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V}, including SINENG ELECTRIC CO LTD: EH-1250-HB-UD-US {690V} (1,250,740 W) at 690 V, 3-phase.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| SINENG ELECTRIC CO LTD: EH-1250-HB-UD-US {690V} SINENG ELECTRIC CO LTD |
1,250,740 W | -49904 W | 690.0 V | 1500.0 V | 98.05% |
| Power Electronics: FS1275CU15 {690V} Power Electronics |
1,389,080 W | +88436 W | 690.0 V | 1200.0 V | 97.72% |
| DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V} DYNAPOWER COMPANY LLC |
1,146,100 W | -154544 W | 690.0 V | 1500.0 V | 98.61% |
| EPC Power Corp: 50-100100 {690V} EPC Power Corp |
1,499,860 W | +199216 W | 690.0 V | 1250.0 V | 96.33% |
What Are the Interconnection Limits and Best-Fit Uses for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V}?
Check INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} (1,300,644 W AC, 1,400 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V}.
INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 1,400 A OCPD breaker (1088.3 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.34%) and MPPT window (962-1,200 V) directly against SINENG ELECTRIC CO LTD: EH-1250-HB-UD-US {690V} (1,250,740 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} by INGETEAM POWER TECHNOLOGY SA covering breaker sizing, MPPT limits, and 690 V, 3-phase interconnection.
What breaker and wire size does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} require?
At 1,300,644 W continuous AC (690 V, 3-phase), continuous current is 1088.3 A; 125% NEC 690.8/705.12 sizing requires a 1,400 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} require?
At 1,300,644 W AC and 690 V, 3-phase, continuous line current is 1088.3 A, requiring a 1,400 A OCPD and 1,200A Bus / 1,200A Main (690V) or NEC 705.11 interconnection.
How does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} compare to SINENG ELECTRIC CO LTD: EH-1250-HB-UD-US {690V}?
INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V} delivers 1,300,644 W AC at 97.34% CEC efficiency with a 1,200 V DC ceiling, while SINENG ELECTRIC CO LTD: EH-1250-HB-UD-US {690V} outputs 1,250,740 W at 690 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)