INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} outputs 1,272,412 W AC at 670 V, 3-phase (1096.5 A continuous, 1,400 A OCPD), ranking #732 of 2,343 CEC inverters at 97.24% efficiency with a 962-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 1,272,412 W
- AC Voltage
- 670 V, 3-phase
- Min PV Breaker
- 1,400 A (parallel Cu feeders)
- CEC Efficiency
- 97.24%
How Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 670 V, 3-phase grid-support overview for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V}.
Ranking #145 of 2,343 CEC inverters (top 6.2%; higher than 93.8% of peers), INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} is a hybrid battery-capable inverter delivering 1,272,412 W continuous AC at 670 V, 3-phase (1096.5 A continuous). Commercial 670 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (670V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 97.24% (equal to the 97.24% 670 V median) against peers like Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W).
Where Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} Fall Across Listed CEC Models?
Marks INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} (1,272,412 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V}?
Benchmarks INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} continuous AC output, 97.24% CEC weighted efficiency, and 1,400 A OCPD breaker demand.
What Do the Dataset Ranks Show for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V}?
Four key NEC 705.12 and California Energy Commission metrics defining INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} by INGETEAM POWER TECHNOLOGY SA.
97.24% CEC Weighted Efficiency
equal to the 97.24% 670 V median; overall power rank #145 (1,272,412 W, top 6.2%; higher than 93.8% of peers).
1,400 A Required Backfeed OCPD
125% x 1096.5 A = 1370.6 A -> 1,400 A standard OCPD using parallel Cu feeders (75 C).
962 V - 1,200 V (Max 1,200 V DC)
Tracking span of 238.0 V; active in CEC directory (hybrid battery-capable inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 670 V, 3-phase switchgear (200A Bus / 200A Main (670V) to 1,200A Bus / 1,200A Main (670V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 1272412.0W / 670 V 3-phase -> 1096.5 A | Breaker >= 1.25 * 1096.5 = 1370.6 A -> 1,400 A
CEC Inverters.csv for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V}: Paco=1272412.0 W, Vac=670 V, Vdcmax=1200.0 V, Eff=97.24%.
Result: Min 1,400 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (670V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 1,272,412 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 670 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,200 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 962 V - 1,200 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 1210.48 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.24% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} (670 V, 3-phase)?
Evaluates INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} (1,400 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (670V) | 40 A | 1,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (670V) | 80 A | 1,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (670V) | 120 A | 1,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (670V) | 160 A | 1,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (670V) | 240 A | 1,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which Competing Grid-Support Inverters Compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V}?
Competing CEC grid-support inverters near 1,272,412 W AC and 670 V, 3-phase, led by Schneider Electric USA Inc: CS1666-3-NA {575V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Schneider Electric USA Inc: CS1666-3-NA {575V} Schneider Electric USA Inc |
1,666,000 W | +393588 W | 575.0 V | 1200.0 V | 97.54% |
| SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V} SINENG ELECTRIC CO LTD |
1,726,700 W | +454288 W | 690.0 V | 1500.0 V | 98.32% |
| EPC Power Corp: 50-200100 {720V} EPC Power Corp |
561,806 W | -710606 W | 720.0 V | 1500.0 V | 98.58% |
| ABB: PVS-175-TL-POWER-MODULE-1-US {800V} ABB |
179,574 W | -1092838 W | 800.0 V | 1200.0 V | 97.39% |
What Are the Interconnection Limits and Best-Fit Uses for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V}?
Check INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} (1,272,412 W AC, 1,400 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 670 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (670V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V}.
INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 1,400 A OCPD breaker (1096.5 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.24%) and MPPT window (962-1,200 V) directly against Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} by INGETEAM POWER TECHNOLOGY SA covering breaker sizing, MPPT limits, and 670 V, 3-phase interconnection.
What breaker and wire size does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} require?
At 1,272,412 W continuous AC (670 V, 3-phase), continuous current is 1096.5 A; 125% NEC 690.8/705.12 sizing requires a 1,400 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} require?
At 1,272,412 W AC and 670 V, 3-phase, continuous line current is 1096.5 A, requiring a 1,400 A OCPD and 1,200A Bus / 1,200A Main (670V) or NEC 705.11 interconnection.
How does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} compare to Schneider Electric USA Inc: CS1666-3-NA {575V}?
INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V} delivers 1,272,412 W AC at 97.24% CEC efficiency with a 1,200 V DC ceiling, while Schneider Electric USA Inc: CS1666-3-NA {575V} outputs 1,666,000 W at 670 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)