Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} — CEC Inverter Specifications

Manufacturer: INGETEAM POWER TECHNOLOGY SA Registry: CEC Verified Engineering Specification

INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} outputs 1,165,000 W AC at 420 V, 3-phase (1601.5 A continuous, 2,050 A OCPD), ranking #555 of 2,343 CEC inverters at 97.48% efficiency with a 610-740 V MPPT window and 740 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
1,165,000 W
AC Voltage
420 V, 3-phase
Min PV Breaker
2,050 A (parallel Cu feeders)
CEC Efficiency
97.48%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} Compare Against Peer CEC Listings?

CEC efficiency rank (#555), 610-740 V MPPT tracking, and panel fit for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V}.

Operating at 420 V, 3-phase, INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} converts DC array energy at 97.48% CEC weighted efficiency (top 23.8%; higher than 76.2% of peers) with a 740 V max DC input and 1770.48 A max input current for NEC 690.7 string safety. Compare this 1,165,000 W hybrid battery-capable inverter directly with Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W). Commercial 420 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (420V) or NEC 705.11 supply-side tap.

Where Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} at 1,165,000 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} (1,165,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACINGETEAM POWER TEC: 1,165,000 W

What Dataset Percentiles Define INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V}?

Dataset percentiles comparing INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} against 2,343 certified grid-support inverters nationwide.

INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} Technical ThresholdsPercentile comparison for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output1,165,000 WCEC Efficiency97.48%Backfeed Breaker2,050 A

What Do the Dataset Ranks Show for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V}?

Engineering highlights for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} covering efficiency, parallel Cu feeders feeder, and panel compatibility.

Eff #555 / 2,343

97.48% CEC Weighted Efficiency

-0.29 pts vs the 97.77% 420 V median; overall power rank #152 (1,165,000 W, top 6.5%; higher than 93.5% of peers).

NEC 705.12 Check

2,050 A Required Backfeed OCPD

125% x 1601.5 A = 2001.9 A -> 2,050 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

610 V - 740 V (Max 740 V DC)

Tracking span of 130.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 420 V, 3-phase switchgear (200A Bus / 200A Main (420V) to 1,200A Bus / 1,200A Main (420V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1165000.0W / 420 V 3-phase -> 1601.5 A | Breaker >= 1.25 * 1601.5 = 2001.9 A -> 2,050 A

CEC Inverters.csv for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V}: Paco=1165000.0 W, Vac=420 V, Vdcmax=740.0 V, Eff=97.48%.

Result: Min 2,050 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (420V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V}?

California Energy Commission Solar Equipment List parameters for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} (hybrid battery-capable inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 1,165,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 420 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 740 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 610 V - 740 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1770.48 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.48% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} (420 V, 3-phase)?

Panelboard and switchgear backfeed allowances for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} (2,050 A OCPD).

Evaluates INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} (2050 A required OCPD at 420 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (420V) 40 A 2,050 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (420V) 80 A 2,050 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (420V) 120 A 2,050 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (420V) 160 A 2,050 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (420V) 240 A 2,050 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which Competing Grid-Support Inverters Compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V}?

Four alternative CEC inverters matched to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} (1,165,000 W AC), led by Schneider Electric USA Inc: CS1666-3-NA {575V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Schneider Electric USA Inc: CS1666-3-NA {575V}
Schneider Electric USA Inc
1,666,000 W +501000 W 575.0 V 1200.0 V 97.54%
SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}
SINENG ELECTRIC CO LTD
1,726,700 W +561700 W 690.0 V 1500.0 V 98.32%
EPC Power Corp: 50-200100 {720V}
EPC Power Corp
561,806 W -603194 W 720.0 V 1500.0 V 98.58%
ABB: PVS-175-TL-POWER-MODULE-1-US {800V}
ABB
179,574 W -985426 W 800.0 V 1200.0 V 97.39%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V}?

Check INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} (1,165,000 W AC, 2,050 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 420 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (420V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 740 V DC on INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V}.

INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 2,050 A OCPD breaker (1601.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.48%) and MPPT window (610-740 V) directly against Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} by INGETEAM POWER TECHNOLOGY SA covering breaker sizing, MPPT limits, and 420 V, 3-phase interconnection.

What breaker and wire size does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} require?

At 1,165,000 W continuous AC (420 V, 3-phase), continuous current is 1601.5 A; 125% NEC 690.8/705.12 sizing requires a 2,050 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} require?

At 1,165,000 W AC and 420 V, 3-phase, continuous line current is 1601.5 A, requiring a 2,050 A OCPD and 1,200A Bus / 1,200A Main (420V) or NEC 705.11 interconnection.

How does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} compare to Schneider Electric USA Inc: CS1666-3-NA {575V}?

INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V} delivers 1,165,000 W AC at 97.48% CEC efficiency with a 740 V DC ceiling, while Schneider Electric USA Inc: CS1666-3-NA {575V} outputs 1,666,000 W at 420 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.