Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} — CEC Inverter Specifications

Manufacturer: INGETEAM POWER TECHNOLOGY SA Registry: CEC Verified Engineering Specification

INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} outputs 1,027,752 W AC at 410 V, 3-phase (1447.3 A continuous, 1,850 A OCPD), ranking #654 of 2,343 CEC inverters at 97.35% efficiency with a 595-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
1,027,752 W
AC Voltage
410 V, 3-phase
Min PV Breaker
1,850 A (parallel Cu feeders)
CEC Efficiency
97.35%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} Compare Against Peer CEC Listings?

Breaker sizing (1,850 A), parallel Cu feeders wire rules, and DC input limits for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}.

For NEC 705.12 solar interconnection, INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} outputs 1447.3 A continuous AC at 410 V, 3-phase and needs a 1,850 A backfeed breaker on parallel Cu feeders (75 C). Commercial 410 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (410V) or NEC 705.11 supply-side tap. Conversion efficiency scores 97.35% (#654 of 2,343, +0.53 pts vs overall CEC median).

Where Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} Fall Across Listed CEC Models?

Output power comparison showing where INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} (1,027,752 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACINGETEAM POWER TEC: 1,027,752 W

What Dataset Percentiles Define INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}?

Relative ranking of INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} Technical ThresholdsPercentile comparison for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output1,027,752 WCEC Efficiency97.35%Backfeed Breaker1,850 A

What Do the Dataset Ranks Show for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}?

Snapshot of INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} efficiency rank (#654), OCPD breaker size, MPPT span, and busbar verdict.

Eff #654 / 2,343

97.35% CEC Weighted Efficiency

equal to the 97.35% 410 V median; overall power rank #165 (1,027,752 W, top 7.0%; higher than 93.0% of peers).

NEC 705.12 Check

1,850 A Required Backfeed OCPD

125% x 1447.3 A = 1809.1 A -> 1,850 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

595 V - 800 V (Max 800 V DC)

Tracking span of 205.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 410 V, 3-phase switchgear (200A Bus / 200A Main (410V) to 1,200A Bus / 1,200A Main (410V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1027752.0W / 410 V 3-phase -> 1447.3 A | Breaker >= 1.25 * 1447.3 = 1809.1 A -> 1,850 A

CEC Inverters.csv for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}: Paco=1027752.0 W, Vac=410 V, Vdcmax=800.0 V, Eff=97.35%.

Result: Min 1,850 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (410V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}.

Official California Energy Commission (NREL SAM) test parameters for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 1,027,752 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 410 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 800 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 595 V - 800 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1580.48 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.35% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} (410 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} at 410 V, 3-phase.

Evaluates INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} (1850 A required OCPD at 410 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (410V) 40 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (410V) 80 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (410V) 120 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (410V) 160 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (410V) 240 A 1,850 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}?

Minimum and maximum series solar module strings fitting INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} MPPT and 800 V limits.

Sampled CEC PV modules aligned within 595.0-800.0 V MPPT and 800.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 14 panels (fixed) 8.26 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 18 panels (fixed) 7.92 kW
Hansol Technics Co Ltd HA650-AE-NNEA0 650.0 W 61.2 V 13 panels (fixed) 8.45 kW
Hyperion Solar HY-DH132P8-480 480.0 W 49.91 V 16 panels (fixed) 7.68 kW

Which Competing Grid-Support Inverters Compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}?

Peer 410 V, 3-phase CEC inverters near 1,027,752 W AC output such as EPC Power Corp: 50-200100 {720V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
EPC Power Corp: 50-200100 {720V}
EPC Power Corp
561,806 W -465946 W 720.0 V 1500.0 V 98.58%
Schneider Electric USA Inc: CS1666-3-NA {575V}
Schneider Electric USA Inc
1,666,000 W +638248 W 575.0 V 1200.0 V 97.54%
SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}
SINENG ELECTRIC CO LTD
1,726,700 W +698948 W 690.0 V 1500.0 V 98.32%
ABB: PVS-175-TL-POWER-MODULE-1-US {800V}
ABB
179,574 W -848178 W 800.0 V 1200.0 V 97.39%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}?

Check INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} (1,027,752 W AC, 1,850 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 410 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (410V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V}.

INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,850 A OCPD breaker (1447.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.35%) and MPPT window (595-800 V) directly against EPC Power Corp: 50-200100 {720V} (561,806 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} by INGETEAM POWER TECHNOLOGY SA covering breaker sizing, MPPT limits, and 410 V, 3-phase interconnection.

What breaker and wire size does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} require?

At 1,027,752 W continuous AC (410 V, 3-phase), continuous current is 1447.3 A; 125% NEC 690.8/705.12 sizing requires a 1,850 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} require?

At 1,027,752 W AC and 410 V, 3-phase, continuous line current is 1447.3 A, requiring a 1,850 A OCPD and 1,200A Bus / 1,200A Main (410V) or NEC 705.11 interconnection.

How does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} compare to EPC Power Corp: 50-200100 {720V}?

INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V} delivers 1,027,752 W AC at 97.35% CEC efficiency with a 800 V DC ceiling, while EPC Power Corp: 50-200100 {720V} outputs 561,806 W at 410 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.