INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} outputs 1,000,000 W AC at 360 V, 3-phase (1603.8 A continuous, 2,050 A OCPD), ranking #856 of 2,343 CEC inverters at 97.13% efficiency with a 524-740 V MPPT window and 740 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 1,000,000 W
- AC Voltage
- 360 V, 3-phase
- Min PV Breaker
- 2,050 A (parallel Cu feeders)
- CEC Efficiency
- 97.13%
How Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} Compare Against Peer CEC Listings?
How INGETEAM POWER TECHNOLOGY SA INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} compares on 97.13% efficiency, MPPT span, and 120% busbar interconnection.
With a 524-740 V MPPT tracking band and 740 V DC ceiling, INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} handles 1,000,000 W continuous AC (equal to the 1,000,000 W 360 V median). Commercial 360 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (360V) or NEC 705.11 supply-side tap. Installers comparing INGETEAM POWER TECHNOLOGY SA against EPC Power Corp: 50-200100 {720V} (561,806 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.
Where Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} Fall Across Listed CEC Models?
Position of INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} (1,000,000 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V}?
Percentile placement of INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V}.
97.13% CEC Weighted Efficiency
equal to the 97.13% 360 V median; overall power rank #167 (1,000,000 W, top 7.2%; higher than 92.8% of peers).
2,050 A Required Backfeed OCPD
125% x 1603.8 A = 2004.8 A -> 2,050 A standard OCPD using parallel Cu feeders (75 C).
524 V - 740 V (Max 740 V DC)
Tracking span of 216.0 V; active in CEC directory (hybrid battery-capable inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 360 V, 3-phase switchgear (200A Bus / 200A Main (360V) to 1,200A Bus / 1,200A Main (360V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 1000000.0W / 360 V 3-phase -> 1603.8 A | Breaker >= 1.25 * 1603.8 = 2004.8 A -> 2,050 A
CEC Inverters.csv for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V}: Paco=1000000.0 W, Vac=360 V, Vdcmax=740.0 V, Eff=97.13%.
Result: Min 2,050 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (360V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 1,000,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 360 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 740 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 524 V - 740 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 1629.0 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.13% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} (360 V, 3-phase)?
Check whether INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} (2,050 A breaker) fits without main breaker derate or supply-side taps.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (360V) | 40 A | 2,050 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (360V) | 80 A | 2,050 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (360V) | 120 A | 2,050 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (360V) | 160 A | 2,050 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (360V) | 240 A | 2,050 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which CEC PV Module Strings Pair With INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V}?
Verified cold-weather (-10 C) series module counts matched to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V}'s 740 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 13 panels (fixed) | 7.67 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 16 to 17 panels | 7.48 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 16 panels (fixed) | 6.8 kW |
| Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 | 515.0 W | 53.76 V | 13 panels (fixed) | 6.7 kW |
Which Competing Grid-Support Inverters Compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V}?
Alternative CEC inverters comparable to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V}, including EPC Power Corp: 50-200100 {720V} (561,806 W) at 360 V, 3-phase.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| EPC Power Corp: 50-200100 {720V} EPC Power Corp |
561,806 W | -438194 W | 720.0 V | 1500.0 V | 98.58% |
| Schneider Electric USA Inc: CS1666-3-NA {575V} Schneider Electric USA Inc |
1,666,000 W | +666000 W | 575.0 V | 1200.0 V | 97.54% |
| SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V} SINENG ELECTRIC CO LTD |
1,726,700 W | +726700 W | 690.0 V | 1500.0 V | 98.32% |
| ABB: PVS-175-TL-POWER-MODULE-1-US {800V} ABB |
179,574 W | -820426 W | 800.0 V | 1200.0 V | 97.39% |
What Are the Interconnection Limits and Best-Fit Uses for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V}?
Check INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} (1,000,000 W AC, 2,050 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 360 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (360V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 740 V DC on INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V}.
INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 2,050 A OCPD breaker (1603.8 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.13%) and MPPT window (524-740 V) directly against EPC Power Corp: 50-200100 {720V} (561,806 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} by INGETEAM POWER TECHNOLOGY SA covering breaker sizing, MPPT limits, and 360 V, 3-phase interconnection.
What breaker and wire size does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} require?
At 1,000,000 W continuous AC (360 V, 3-phase), continuous current is 1603.8 A; 125% NEC 690.8/705.12 sizing requires a 2,050 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} require?
At 1,000,000 W AC and 360 V, 3-phase, continuous line current is 1603.8 A, requiring a 2,050 A OCPD and 1,200A Bus / 1,200A Main (360V) or NEC 705.11 interconnection.
How does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} compare to EPC Power Corp: 50-200100 {720V}?
INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V} delivers 1,000,000 W AC at 97.13% CEC efficiency with a 740 V DC ceiling, while EPC Power Corp: 50-200100 {720V} outputs 561,806 W at 360 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)