Hyperian Energy Inc: ST2-120i {240V} — CEC Inverter Specifications

Manufacturer: Hyperian Energy Inc Registry: CEC Verified Engineering Specification

Hyperian Energy Inc: ST2-120i {240V} outputs 11,968 W AC at 240 V (49.9 A continuous, 70 A OCPD), ranking #946 of 2,343 CEC inverters at 97.04% efficiency with a 300-440 V MPPT window and 440 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
11,968 W
AC Voltage
240 V
Min PV Breaker
70 A (4 AWG Cu)
CEC Efficiency
97.04%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hyperian Energy Inc: ST2-120i {240V} Compare Against Peer CEC Listings?

Breaker sizing (70 A), 4 AWG Cu wire rules, and DC input limits for Hyperian Energy Inc: ST2-120i {240V}.

Classified as a hybrid battery-capable inverter (active in CEC directory), Hyperian Energy Inc: ST2-120i {240V} requires 62.4 A design capacity -> 70 A breaker using 4 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 97.04% (+0.22 pts vs overall CEC median) across 2,343 CEC models, while its 70 a backfeed breaker exceeds a 200a/200a panel's 40 a ceiling, requiring a 175 a main derate, 225 a busbar, or nec 705.11 tap.

Where Does Hyperian Energy Inc: ST2-120i {240V} Fall Across Listed CEC Models?

Output power comparison showing where Hyperian Energy Inc: ST2-120i {240V} sits among all 2,343 CEC-listed grid-support inverters. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Hyperian Energy Inc: ST2-120i {240V} (11,968 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACHyperian Energy In: 11,968 W

What Dataset Percentiles Define Hyperian Energy Inc: ST2-120i {240V}?

Relative ranking of Hyperian Energy Inc: ST2-120i {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Hyperian Energy Inc: ST2-120i {240V} Technical ThresholdsPercentile comparison for Hyperian Energy Inc: ST2-120i {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output11,968 WCEC Efficiency97.04%Backfeed Breaker70 A

What Do the Dataset Ranks Show for Hyperian Energy Inc: ST2-120i {240V}?

Snapshot of Hyperian Energy Inc: ST2-120i {240V} efficiency rank (#946), OCPD breaker size, MPPT span, and busbar verdict.

Eff #946 / 2,343

97.04% CEC Weighted Efficiency

+0.36 pts vs the 96.68% 240 V median; overall power rank #740 (11,968 W, top 31.6%; higher than 68.4% of peers).

NEC 705.12 Check

70 A Required Backfeed OCPD

125% x 49.9 A = 62.4 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

300 V - 440 V (Max 440 V DC)

Tracking span of 140.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 11968.0W / 240 V -> 49.9 A | Breaker >= 1.25 * 49.9 = 62.4 A -> 70 A

CEC Inverters.csv for Hyperian Energy Inc: ST2-120i {240V}: Paco=11968.0 W, Vac=240 V, Vdcmax=440.0 V, Eff=97.04%.

Result: Min 70 A breaker & 4 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Hyperian Energy Inc: ST2-120i {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Hyperian Energy Inc: ST2-120i {240V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Hyperian Energy Inc: ST2-120i {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 11,968 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 440 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 300 V - 440 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 33.3322 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.04% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Hyperian Energy Inc: ST2-120i {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Hyperian Energy Inc: ST2-120i {240V} at 240 V. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Evaluates Hyperian Energy Inc: ST2-120i {240V} (70 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 70 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 70 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 70 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 70 A Needs Derate / Tap 705.11
225A Bus / 200A Main 70 A 70 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Hyperian Energy Inc: ST2-120i {240V}?

Minimum and maximum series solar module strings fitting Hyperian Energy Inc: ST2-120i {240V} MPPT and 440 V limits.

Sampled CEC PV modules aligned within 300.0-440.0 V MPPT and 440.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 7 panels (fixed) 4.13 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 9 to 10 panels 4.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 9 panels (fixed) 3.83 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 8 panels (fixed) 4.12 kW

Which Competing Grid-Support Inverters Compare to Hyperian Energy Inc: ST2-120i {240V}?

Peer 240 V CEC inverters near 11,968 W AC output such as Chint Power Systems America: CPS ECH12KTL/US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Chint Power Systems America: CPS ECH12KTL/US {240V}
Chint Power Systems America
11,990 W +22 W 240.0 V 480.0 V 96.59%
Amensolar Ess Co Ltd: N3H-X12US {240V}
Amensolar Ess Co Ltd
12,214 W +246 W 240.0 V 430.0 V 96.17%
Delta Electronics: S12_BDI {240V}
Delta Electronics
11,589 W -379 W 240.0 V 480.0 V 96.99%
Base Power Inc: MIN 11400TL-XH-US {240V}
Base Power Inc
11,520 W -448 W 240.0 V 480.0 V 97.76%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Hyperian Energy Inc: ST2-120i {240V}?

Check Hyperian Energy Inc: ST2-120i {240V} (11,968 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 70 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 440 V DC on Hyperian Energy Inc: ST2-120i {240V}.

Hyperian Energy Inc: ST2-120i {240V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (49.9 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.04%) and MPPT window (300-440 V) directly against Chint Power Systems America: CPS ECH12KTL/US {240V} (11,990 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Hyperian Energy Inc: ST2-120i {240V} by Hyperian Energy Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Hyperian Energy Inc: ST2-120i {240V} require?

At 11,968 W continuous AC (240 V), continuous current is 49.9 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

Does Hyperian Energy Inc: ST2-120i {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 70 A at 240 V means Needs Derate / Tap 705.11.

How does Hyperian Energy Inc: ST2-120i {240V} compare to Chint Power Systems America: CPS ECH12KTL/US {240V}?

Hyperian Energy Inc: ST2-120i {240V} delivers 11,968 W AC at 97.04% CEC efficiency with a 440 V DC ceiling, while Chint Power Systems America: CPS ECH12KTL/US {240V} outputs 11,990 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.