Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

HiQ Solar: TSXL480-10k {480V} — CEC Inverter Specifications

Manufacturer: HiQ Solar Registry: CEC Verified Engineering Specification

HiQ Solar: TSXL480-10k {480V} outputs 9,975 W AC at 480 V, 3-phase (12.0 A continuous, 15 A OCPD), ranking #314 of 2,343 CEC inverters at 98.06% efficiency with a 450-850 V MPPT window and 850 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
9,975 W
AC Voltage
480 V, 3-phase
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
98.06%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does HiQ Solar: TSXL480-10k {480V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for HiQ Solar: TSXL480-10k {480V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rated at 9,975 W AC (12.0 A continuous), HiQ Solar: TSXL480-10k {480V} ranks #314 of 2,343 CEC units at 98.06% efficiency (+0.04 pts vs the 98.02% 480 V median). Minimum 75 C copper conductor sizing for its 15 A circuit is 14 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 850 V DC at record local winter lows.

Where Does HiQ Solar: TSXL480-10k {480V} Fall Across Listed CEC Models?

Marks HiQ Solar: TSXL480-10k {480V} (9,975 W AC) across the California Energy Commission inverter AC capacity distribution. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where HiQ Solar: TSXL480-10k {480V} (9,975 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACHiQ Solar: TSXL480: 9,975 W

What Dataset Percentiles Define HiQ Solar: TSXL480-10k {480V}?

Benchmarks HiQ Solar: TSXL480-10k {480V} continuous AC output, 98.06% CEC weighted efficiency, and 15 A OCPD breaker demand.

HiQ Solar: TSXL480-10k {480V} Technical ThresholdsPercentile comparison for HiQ Solar: TSXL480-10k {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output9,975 WCEC Efficiency98.06%Backfeed Breaker15 A

What Do the Dataset Ranks Show for HiQ Solar: TSXL480-10k {480V}?

Four key NEC 705.12 and California Energy Commission metrics defining HiQ Solar: TSXL480-10k {480V} by HiQ Solar. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Eff #314 / 2,343

98.06% CEC Weighted Efficiency

+0.04 pts vs the 98.02% 480 V median; overall power rank #923 (9,975 W, top 39.5%; higher than 60.5% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 12.0 A = 15.0 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

450 V - 850 V (Max 850 V DC)

Tracking span of 400.0 V; listed since 2019-02-15 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 9975.0W / 480 V 3-phase -> 12.0 A | Breaker >= 1.25 * 12.0 = 15.0 A -> 15 A

CEC Inverters.csv for HiQ Solar: TSXL480-10k {480V}: Paco=9975.0 W, Vac=480 V, Vdcmax=850.0 V, Eff=98.06%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for HiQ Solar: TSXL480-10k {480V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for HiQ Solar: TSXL480-10k {480V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Official California Energy Commission (NREL SAM) test parameters for HiQ Solar: TSXL480-10k {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 9,975 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 850 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 450 V - 850 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 13.5625 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.06% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2019-02-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to HiQ Solar: TSXL480-10k {480V} (480 V, 3-phase)?

Evaluates HiQ Solar: TSXL480-10k {480V} (15 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates HiQ Solar: TSXL480-10k {480V} (15 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 15 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (480V) 80 A 15 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (480V) 120 A 15 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 15 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 15 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With HiQ Solar: TSXL480-10k {480V}?

Sample PV string lengths aligned within 450-850 V MPPT and 850 V DC max at -10 C. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sampled CEC PV modules aligned within 450.0-850.0 V MPPT and 850.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 11 to 15 panels 8.85 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 14 to 20 panels 8.8 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 14 to 18 panels 7.65 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 16 to 20 panels 4.0 kW

Which Competing Grid-Support Inverters Compare to HiQ Solar: TSXL480-10k {480V}?

Competing CEC grid-support inverters near 9,975 W AC and 480 V, 3-phase, led by Fronius International GmbH: Fronius Symo 100-3 480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Fronius International GmbH: Fronius Symo 100-3 480 {480V}
Fronius International GmbH
9,995 W +20 W 480.0 V 800.0 V 97.42%
Fronius International GmbH: Fronius Symo 125-3 480 {480V}
Fronius International GmbH
12,500 W +2525 W 480.0 V 800.0 V 97.57%
Fronius International GmbH: Fronius Symo 150-3 480 {480V}
Fronius International GmbH
15,000 W +5025 W 480.0 V 800.0 V 97.47%
Fronius International GmbH: Fronius Symo Advanced 150-3 480 {480V}
Fronius International GmbH
15,197 W +5222 W 480.0 V 800.0 V 97.48%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for HiQ Solar: TSXL480-10k {480V}?

Check HiQ Solar: TSXL480-10k {480V} (9,975 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 850 V DC on HiQ Solar: TSXL480-10k {480V}.

HiQ Solar: TSXL480-10k {480V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (12.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.06%) and MPPT window (450-850 V) directly against Fronius International GmbH: Fronius Symo 100-3 480 {480V} (9,995 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for HiQ Solar: TSXL480-10k {480V} by HiQ Solar covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does HiQ Solar: TSXL480-10k {480V} require?

At 9,975 W continuous AC (480 V, 3-phase), continuous current is 12.0 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does HiQ Solar: TSXL480-10k {480V} require?

At 9,975 W AC and 480 V, 3-phase, continuous line current is 12.0 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does HiQ Solar: TSXL480-10k {480V} compare to Fronius International GmbH: Fronius Symo 100-3 480 {480V}?

HiQ Solar: TSXL480-10k {480V} delivers 9,975 W AC at 98.06% CEC efficiency with a 850 V DC ceiling, while Fronius International GmbH: Fronius Symo 100-3 480 {480V} outputs 9,995 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.