GoodWe Technologies Co Ltd: GW9600A-MS {208V} outputs 9,628 W AC at 208 V, commercial single-phase (46.3 A continuous, 60 A OCPD), ranking #1,958 of 2,343 CEC inverters at 96.0% efficiency with a 300-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 9,628 W
- AC Voltage
- 208 V, commercial single-phase
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 96.0%
How Does GoodWe Technologies Co Ltd: GW9600A-MS {208V} Compare Against Peer CEC Listings?
CEC efficiency rank (#1,958), 300-480 V MPPT tracking, and panel fit for GoodWe Technologies Co Ltd: GW9600A-MS {208V}.
Operating at 208 V, commercial single-phase, GoodWe Technologies Co Ltd: GW9600A-MS {208V} converts DC array energy at 96.0% CEC weighted efficiency (below overall CEC median; higher than 14.9% of peers) with a 480 V max DC input and 25.0726 A max input current for NEC 690.7 string safety. Compare this 9,628 W grid-tied PV inverter directly with Chint Power Systems America: CPS ECH96KTL/US {208V} (9,550 W). Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
Where Does GoodWe Technologies Co Ltd: GW9600A-MS {208V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting GoodWe Technologies Co Ltd: GW9600A-MS {208V} at 9,628 W continuous AC output. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Dataset Percentiles Define GoodWe Technologies Co Ltd: GW9600A-MS {208V}?
Dataset percentiles comparing GoodWe Technologies Co Ltd: GW9600A-MS {208V} against 2,343 certified grid-support inverters nationwide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Do the Dataset Ranks Show for GoodWe Technologies Co Ltd: GW9600A-MS {208V}?
Engineering highlights for GoodWe Technologies Co Ltd: GW9600A-MS {208V} covering efficiency, 6 AWG Cu feeder, and panel compatibility.
96.0% CEC Weighted Efficiency
-0.41 pts vs the 96.41% 208 V median; overall power rank #963 (9,628 W, top 41.4%; higher than 58.6% of peers).
60 A Required Backfeed OCPD
125% x 46.3 A = 57.9 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
300 V - 480 V (Max 480 V DC)
Tracking span of 180.0 V; listed since 2023-02-13 (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 9628.0W / 208 V -> 46.3 A | Breaker >= 1.25 * 46.3 = 57.9 A -> 60 A
CEC Inverters.csv for GoodWe Technologies Co Ltd: GW9600A-MS {208V}: Paco=9628.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=96.0%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for GoodWe Technologies Co Ltd: GW9600A-MS {208V}?
California Energy Commission Solar Equipment List parameters for GoodWe Technologies Co Ltd: GW9600A-MS {208V} (grid-tied PV inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 9,628 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 300 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 25.0726 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.0% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2023-02-13 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
What Switchgear Limits Apply to GoodWe Technologies Co Ltd: GW9600A-MS {208V} (208 V, commercial single-phase)?
Panelboard and switchgear backfeed allowances for GoodWe Technologies Co Ltd: GW9600A-MS {208V} (60 A OCPD). Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 60 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (208V) | 80 A | 60 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 60 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 60 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 60 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With GoodWe Technologies Co Ltd: GW9600A-MS {208V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for GoodWe Technologies Co Ltd: GW9600A-MS {208V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 7 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 9 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 9 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 11 panels (fixed) | 2.2 kW |
Which Competing Grid-Support Inverters Compare to GoodWe Technologies Co Ltd: GW9600A-MS {208V}?
Four alternative CEC inverters matched to GoodWe Technologies Co Ltd: GW9600A-MS {208V} (9,628 W AC), led by Chint Power Systems America: CPS ECH96KTL/US {208V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Chint Power Systems America: CPS ECH96KTL/US {208V} Chint Power Systems America |
9,550 W | -78 W | 208.0 V | 480.0 V | 96.73% |
| Altenergy Power System Inc: ELS-114 {208V} Altenergy Power System Inc |
10,011 W | +383 W | 208.0 V | 60.0 V | 92.83% |
| Delta Electronics: S12_BDI {208V} Delta Electronics |
10,057 W | +429 W | 208.0 V | 480.0 V | 96.7% |
| EG4 Electronics LLC: 18KPV-12LV {208V} EG4 Electronics LLC |
10,499 W | +871 W | 208.0 V | 480.0 V | 96.07% |
What Are the Interconnection Limits and Best-Fit Uses for GoodWe Technologies Co Ltd: GW9600A-MS {208V}?
Check GoodWe Technologies Co Ltd: GW9600A-MS {208V} (9,628 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on GoodWe Technologies Co Ltd: GW9600A-MS {208V}.
GoodWe Technologies Co Ltd: GW9600A-MS {208V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (46.3 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.0%) and MPPT window (300-480 V) directly against Chint Power Systems America: CPS ECH96KTL/US {208V} (9,550 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for GoodWe Technologies Co Ltd: GW9600A-MS {208V} by GoodWe Technologies Co Ltd covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.
What breaker and wire size does GoodWe Technologies Co Ltd: GW9600A-MS {208V} require?
At 9,628 W continuous AC (208 V, commercial single-phase), continuous current is 46.3 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does GoodWe Technologies Co Ltd: GW9600A-MS {208V} require?
At 9,628 W AC and 208 V, commercial single-phase, continuous line current is 46.3 A, requiring a 60 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does GoodWe Technologies Co Ltd: GW9600A-MS {208V} compare to Chint Power Systems America: CPS ECH96KTL/US {208V}?
GoodWe Technologies Co Ltd: GW9600A-MS {208V} delivers 9,628 W AC at 96.0% CEC efficiency with a 480 V DC ceiling, while Chint Power Systems America: CPS ECH96KTL/US {208V} outputs 9,550 W at 208 V, commercial single-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)