Manufacturer: GoodWe Technologies Co Ltd Registry: CEC Verified Engineering Specification

GoodWe Technologies Co Ltd: GW8600A-BP {240V} outputs 8,680 W AC at 240 V (36.2 A continuous, 50 A OCPD), ranking #1,785 of 2,343 CEC inverters at 96.28% efficiency with a 200-495 V MPPT window and 495 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
8,680 W
AC Voltage
240 V
Min PV Breaker
50 A (8 AWG Cu)
CEC Efficiency
96.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does GoodWe Technologies Co Ltd: GW8600A-BP {240V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for GoodWe Technologies Co Ltd: GW8600A-BP {240V}.

Ranking #1,049 of 2,343 CEC inverters (top 44.8%; higher than 55.2% of peers), GoodWe Technologies Co Ltd: GW8600A-BP {240V} is a grid-tied PV inverter delivering 8,680 W continuous AC at 240 V (36.2 A continuous). Its 50 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Weighted CEC efficiency reaches 96.28% (-0.40 pts vs the 96.68% 240 V median) against peers like ABB: UNO-86-TL-OUTD-S-US-A {240V} (8,600 W).

Where Does GoodWe Technologies Co Ltd: GW8600A-BP {240V} Fall Across Listed CEC Models?

Marks GoodWe Technologies Co Ltd: GW8600A-BP {240V} (8,680 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where GoodWe Technologies Co Ltd: GW8600A-BP {240V} (8,680 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACGoodWe Technologie: 8,680 W

What Dataset Percentiles Define GoodWe Technologies Co Ltd: GW8600A-BP {240V}?

Benchmarks GoodWe Technologies Co Ltd: GW8600A-BP {240V} continuous AC output, 96.28% CEC weighted efficiency, and 50 A OCPD breaker demand.

GoodWe Technologies Co Ltd: GW8600A-BP {240V} Technical ThresholdsPercentile comparison for GoodWe Technologies Co Ltd: GW8600A-BP {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output8,680 WCEC Efficiency96.28%Backfeed Breaker50 A

What Do the Dataset Ranks Show for GoodWe Technologies Co Ltd: GW8600A-BP {240V}?

Four key NEC 705.12 and California Energy Commission metrics defining GoodWe Technologies Co Ltd: GW8600A-BP {240V} by GoodWe Technologies Co Ltd.

Eff #1,785 / 2,343

96.28% CEC Weighted Efficiency

-0.40 pts vs the 96.68% 240 V median; overall power rank #1,049 (8,680 W, top 44.8%; higher than 55.2% of peers).

NEC 705.12 Check

50 A Required Backfeed OCPD

125% x 36.2 A = 45.2 A -> 50 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

200 V - 495 V (Max 495 V DC)

Tracking span of 295.0 V; listed since 2023-12-11 (grid-tied PV inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 8680.0W / 240 V -> 36.2 A | Breaker >= 1.25 * 36.2 = 45.2 A -> 50 A

CEC Inverters.csv for GoodWe Technologies Co Ltd: GW8600A-BP {240V}: Paco=8680.0 W, Vac=240 V, Vdcmax=495.0 V, Eff=96.28%.

Result: Min 50 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for GoodWe Technologies Co Ltd: GW8600A-BP {240V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for GoodWe Technologies Co Ltd: GW8600A-BP {240V}.

Official California Energy Commission (NREL SAM) test parameters for GoodWe Technologies Co Ltd: GW8600A-BP {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 8,680 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 495 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 200 V - 495 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 25.7592 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.28% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2023-12-11 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for GoodWe Technologies Co Ltd: GW8600A-BP {240V}?

Evaluates GoodWe Technologies Co Ltd: GW8600A-BP {240V} (50 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates GoodWe Technologies Co Ltd: GW8600A-BP {240V} (50 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 50 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 50 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 50 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 50 A PASS (120% Rule)
225A Bus / 200A Main 70 A 50 A PASS (120% Rule)

Which CEC PV Module Strings Pair With GoodWe Technologies Co Ltd: GW8600A-BP {240V}?

Sample PV string lengths aligned within 200-495 V MPPT and 495 V DC max at -10 C. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sampled CEC PV modules aligned within 200.0-495.0 V MPPT and 495.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 11 panels 4.67 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 12 panels 2.4 kW

Which Competing Grid-Support Inverters Compare to GoodWe Technologies Co Ltd: GW8600A-BP {240V}?

Competing CEC grid-support inverters near 8,680 W AC and 240 V, led by ABB: UNO-86-TL-OUTD-S-US-A {240V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: UNO-86-TL-OUTD-S-US-A {240V}
ABB
8,600 W -80 W 240.0 V 480.0 V 97.03%
ABB: UNO-86-TL-OUTD-S-US-Z-A {240V}
ABB
8,600 W -80 W 240.0 V 480.0 V 97.03%
ABB: UNO-86-TL-OUTD-S-US-Z-M-A {240V}
ABB
8,600 W -80 W 240.0 V 480.0 V 97.03%
Afore New Energy Technology (Shanghai) Co Ltd: AF86K-DH {240V}
Afore New Energy Technology (Shanghai) Co Ltd
8,596 W -84 W 240.0 V 480.0 V 97.91%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for GoodWe Technologies Co Ltd: GW8600A-BP {240V}?

Check GoodWe Technologies Co Ltd: GW8600A-BP {240V} (8,680 W AC, 50 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 50 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 495 V DC on GoodWe Technologies Co Ltd: GW8600A-BP {240V}.

GoodWe Technologies Co Ltd: GW8600A-BP {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 50 A OCPD breaker (36.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.28%) and MPPT window (200-495 V) directly against ABB: UNO-86-TL-OUTD-S-US-A {240V} (8,600 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for GoodWe Technologies Co Ltd: GW8600A-BP {240V} by GoodWe Technologies Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does GoodWe Technologies Co Ltd: GW8600A-BP {240V} require?

At 8,680 W continuous AC (240 V), continuous current is 36.2 A; 125% NEC 690.8/705.12 sizing requires a 50 A breaker and 8 AWG Cu (75 C) wire.

Does GoodWe Technologies Co Ltd: GW8600A-BP {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 50 A at 240 V means Needs Derate / Tap 705.11.

How does GoodWe Technologies Co Ltd: GW8600A-BP {240V} compare to ABB: UNO-86-TL-OUTD-S-US-A {240V}?

GoodWe Technologies Co Ltd: GW8600A-BP {240V} delivers 8,680 W AC at 96.28% CEC efficiency with a 495 V DC ceiling, while ABB: UNO-86-TL-OUTD-S-US-A {240V} outputs 8,600 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.