Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} outputs 39,926 W AC at 480 V, 3-phase (48.0 A continuous, 60 A OCPD), ranking #155 of 2,343 CEC inverters at 98.34% efficiency with a 556-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 39,926 W
- AC Voltage
- 480 V, 3-phase
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 98.34%
How Does Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} Compare Against Peer CEC Listings?
How Ginlong Technologies Co Ltd Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} compares on 98.34% efficiency, MPPT span, and 120% busbar interconnection.
Ginlong Technologies Co Ltd certifies Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} (grid-tied PV inverter, active in CEC directory) at 39,926 W AC (10,074 W below the 50,000 W 480 V median). Its 800 V DC ceiling pairs with an MPPT window of 556-800 V (span 244.0 V). Under NEC 690.8/705.12, 125% sizing demands 6 AWG Cu conductors on a 60 A OCPD.
Where Does Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} Fall Across Listed CEC Models?
Position of Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} (39,926 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V}?
Percentile placement of Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V}.
98.34% CEC Weighted Efficiency
+0.32 pts vs the 98.02% 480 V median; overall power rank #488 (39,926 W, top 20.9%; higher than 79.1% of peers).
60 A Required Backfeed OCPD
125% x 48.0 A = 60.0 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
556 V - 800 V (Max 800 V DC)
Tracking span of 244.0 V; active in CEC directory (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 39926.0W / 480 V 3-phase -> 48.0 A | Breaker >= 1.25 * 48.0 = 60.0 A -> 60 A
CEC Inverters.csv for Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V}: Paco=39926.0 W, Vac=480 V, Vdcmax=800.0 V, Eff=98.34%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 39,926 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 800 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 556 V - 800 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 58.0021 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 98.34% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} (480 V, 3-phase)?
Check whether Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} (60 A breaker) fits without main breaker derate or supply-side taps.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (480V) | 40 A | 60 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (480V) | 80 A | 60 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (480V) | 120 A | 60 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (480V) | 160 A | 60 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (480V) | 240 A | 60 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V}?
Verified cold-weather (-10 C) series module counts matched to Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V}'s 800 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 13 to 14 panels | 8.26 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 17 to 18 panels | 7.92 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 17 panels (fixed) | 7.22 kW |
| Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 | 515.0 W | 53.76 V | 14 panels (fixed) | 7.21 kW |
Which Competing Grid-Support Inverters Compare to Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V}?
Alternative CEC inverters comparable to Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V}, including CSI Solar Co Ltd: CSI-40K-T480GL01-UB {480V} (39,926 W) at 480 V, 3-phase.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| CSI Solar Co Ltd: CSI-40K-T480GL01-UB {480V} CSI Solar Co Ltd |
39,926 W | Tie (0 W) | 480.0 V | 800.0 V | 98.34% |
| Canadian Solar Inc: CSI-40KTL-GS {480V} Canadian Solar Inc |
40,000 W | +74 W | 480.0 V | 780.0 V | 98.0% |
| Canadian Solar Inc: CSI-40KTL-GS-FL {480V} Canadian Solar Inc |
40,000 W | +74 W | 480.0 V | 780.0 V | 98.16% |
| CSI Solar Co Ltd: CSI-40KTL-GS-B {480V} CSI Solar Co Ltd |
40,000 W | +74 W | 480.0 V | 780.0 V | 98.19% |
What Are the Interconnection Limits and Best-Fit Uses for Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V}?
Check Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} (39,926 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V}.
Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (48.0 A continuous).
Alternative Inverter Comparison
Compare efficiency (98.34%) and MPPT window (556-800 V) directly against CSI Solar Co Ltd: CSI-40K-T480GL01-UB {480V} (39,926 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} by Ginlong Technologies Co Ltd covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.
What breaker and wire size does Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} require?
At 39,926 W continuous AC (480 V, 3-phase), continuous current is 48.0 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} require?
At 39,926 W AC and 480 V, 3-phase, continuous line current is 48.0 A, requiring a 60 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.
How does Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} compare to CSI Solar Co Ltd: CSI-40K-T480GL01-UB {480V}?
Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V} delivers 39,926 W AC at 98.34% CEC efficiency with a 800 V DC ceiling, while CSI Solar Co Ltd: CSI-40K-T480GL01-UB {480V} outputs 39,926 W at 480 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)