Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} — CEC Inverter Specifications

Manufacturer: Ginlong Technologies Co Ltd Registry: CEC Verified Engineering Specification

Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} outputs 24,958 W AC at 480 V, 3-phase (30.0 A continuous, 40 A OCPD), ranking #148 of 2,343 CEC inverters at 98.35% efficiency with a 347-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
24,958 W
AC Voltage
480 V, 3-phase
Min PV Breaker
40 A (8 AWG Cu)
CEC Efficiency
98.35%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V}.

Rated at 24,958 W AC (30.0 A continuous), Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} ranks #148 of 2,343 CEC units at 98.35% efficiency (+0.33 pts vs the 98.02% 480 V median). Minimum 75 C copper conductor sizing for its 40 A circuit is 8 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 800 V DC at record local winter lows.

Where Does Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} Fall Across Listed CEC Models?

Marks Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} (24,958 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} (24,958 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACGinlong Technologi: 24,958 W

What Dataset Percentiles Define Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V}?

Benchmarks Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} continuous AC output, 98.35% CEC weighted efficiency, and 40 A OCPD breaker demand.

Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} Technical ThresholdsPercentile comparison for Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output24,958 WCEC Efficiency98.35%Backfeed Breaker40 A

What Do the Dataset Ranks Show for Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V}?

Four key NEC 705.12 and California Energy Commission metrics defining Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} by Ginlong Technologies Co Ltd.

Eff #148 / 2,343

98.35% CEC Weighted Efficiency

+0.33 pts vs the 98.02% 480 V median; overall power rank #607 (24,958 W, top 25.9%; higher than 74.1% of peers).

NEC 705.12 Check

40 A Required Backfeed OCPD

125% x 30.0 A = 37.5 A -> 40 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

347 V - 800 V (Max 800 V DC)

Tracking span of 453.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 24958.0W / 480 V 3-phase -> 30.0 A | Breaker >= 1.25 * 30.0 = 37.5 A -> 40 A

CEC Inverters.csv for Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V}: Paco=24958.0 W, Vac=480 V, Vdcmax=800.0 V, Eff=98.35%.

Result: Min 40 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V}.

Official California Energy Commission (NREL SAM) test parameters for Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 24,958 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 800 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 347 V - 800 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 53.9951 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.35% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} (480 V, 3-phase)?

Evaluates Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} (40 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} (40 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 40 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (480V) 80 A 40 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (480V) 120 A 40 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 40 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 40 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V}?

Sample PV string lengths aligned within 347-800 V MPPT and 800 V DC max at -10 C. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sampled CEC PV modules aligned within 347.0-800.0 V MPPT and 800.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 9 to 14 panels 8.26 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 11 to 18 panels 7.92 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 11 to 17 panels 7.22 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 13 to 19 panels 3.8 kW

Which Competing Grid-Support Inverters Compare to Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V}?

Competing CEC grid-support inverters near 24,958 W AC and 480 V, 3-phase, led by CSI Solar Co Ltd: CSI-25K-T480GL01-UB {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
CSI Solar Co Ltd: CSI-25K-T480GL01-UB {480V}
CSI Solar Co Ltd
24,958 W Tie (0 W) 480.0 V 800.0 V 98.35%
Canadian Solar Inc: CSI-25KTL-GS-FL {480V}
Canadian Solar Inc
25,000 W +42 W 480.0 V 780.0 V 97.73%
Chint Power Systems America: CPS SCA25KTL-DO-R/US-480 {480V}
Chint Power Systems America
25,000 W +42 W 480.0 V 850.0 V 97.85%
CSI Solar Co Ltd: CSI-25KTL-GS-FLB {480V}
CSI Solar Co Ltd
25,000 W +42 W 480.0 V 770.0 V 97.78%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V}?

Check Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} (24,958 W AC, 40 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V}.

Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 40 A OCPD breaker (30.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.35%) and MPPT window (347-800 V) directly against CSI Solar Co Ltd: CSI-25K-T480GL01-UB {480V} (24,958 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} by Ginlong Technologies Co Ltd covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} require?

At 24,958 W continuous AC (480 V, 3-phase), continuous current is 30.0 A; 125% NEC 690.8/705.12 sizing requires a 40 A breaker and 8 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} require?

At 24,958 W AC and 480 V, 3-phase, continuous line current is 30.0 A, requiring a 40 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} compare to CSI Solar Co Ltd: CSI-25K-T480GL01-UB {480V}?

Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V} delivers 24,958 W AC at 98.35% CEC efficiency with a 800 V DC ceiling, while CSI Solar Co Ltd: CSI-25K-T480GL01-UB {480V} outputs 24,958 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.