Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} outputs 4,600 W AC at 240 V (19.2 A continuous, 25 A OCPD), ranking #1,075 of 2,343 CEC inverters at 96.96% efficiency with a 200-500 V MPPT window and 500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 4,600 W
- AC Voltage
- 240 V
- Min PV Breaker
- 25 A (10 AWG Cu)
- CEC Efficiency
- 96.96%
How Does Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} Compare Against Peer CEC Listings?
CEC efficiency rank (#1,075), 200-500 V MPPT tracking, and panel fit for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}.
Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} from Ginlong Technologies Co Ltd outputs 19.2 A continuous AC at 240 V (4,600 W AC, rank #1,582). Paired with 10 AWG Cu conductors and a 25 A OCPD, its 96.96% CEC efficiency compares closely with ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V} (4,600 W). Keep NEC 690.7 winter string Voc below 500 V DC.
Where Does Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} at 4,600 W continuous AC output. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Dataset Percentiles Define Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}?
Dataset percentiles comparing Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} against 2,343 certified grid-support inverters nationwide. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Do the Dataset Ranks Show for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}?
Engineering highlights for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} covering efficiency, 10 AWG Cu feeder, and panel compatibility.
96.96% CEC Weighted Efficiency
+0.28 pts vs the 96.68% 240 V median; overall power rank #1,582 (4,600 W, below CEC median; higher than 32.0% of peers).
25 A Required Backfeed OCPD
125% x 19.2 A = 24.0 A -> 25 A standard OCPD using 10 AWG Cu (75 C).
200 V - 500 V (Max 500 V DC)
Tracking span of 300.0 V; listed since 2020-09-11 (grid-tied PV inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 4600.0W / 240 V -> 19.2 A | Breaker >= 1.25 * 19.2 = 24.0 A -> 25 A
CEC Inverters.csv for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}: Paco=4600.0 W, Vac=240 V, Vdcmax=500.0 V, Eff=96.96%.
Result: Min 25 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}?
California Energy Commission Solar Equipment List parameters for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} (grid-tied PV inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 4,600 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 200 V - 500 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 13.1783 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.96% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2020-09-11 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}?
Panelboard and switchgear backfeed allowances for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} (25 A OCPD). Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 25 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 25 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 25 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 25 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 25 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 5 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 6 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 6 to 11 panels | 4.67 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 7 to 12 panels | 2.4 kW |
Which Competing Grid-Support Inverters Compare to Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}?
Four alternative CEC inverters matched to Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} (4,600 W AC), led by ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V} ABB |
4,600 W | Tie (0 W) | 240.0 V | 480.0 V | 96.17% |
| ABB: UNO-DM-46-TL-PLUS-US-SB-RA-Q {240V} ABB |
4,600 W | Tie (0 W) | 240.0 V | 480.0 V | 96.17% |
| ABB: UNO-DM-46-TL-PLUS-US-SE-RA {240V} ABB |
4,600 W | Tie (0 W) | 240.0 V | 480.0 V | 96.17% |
| ABB: UNO-DM-46-TL-PLUS-US-SZ-RA {240V} ABB |
4,600 W | Tie (0 W) | 240.0 V | 480.0 V | 96.17% |
What Are the Interconnection Limits and Best-Fit Uses for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}?
Check Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} (4,600 W AC, 25 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 25 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 500 V DC on Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V}.
Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} Panel & Wire Spec
Size 75 C copper conductors at 10 AWG Cu on a 25 A OCPD breaker (19.2 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.96%) and MPPT window (200-500 V) directly against ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V} (4,600 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} by Ginlong Technologies Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} require?
At 4,600 W continuous AC (240 V), continuous current is 19.2 A; 125% NEC 690.8/705.12 sizing requires a 25 A breaker and 10 AWG Cu (75 C) wire.
Does Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 25 A at 240 V means PASS (120% Rule).
How does Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} compare to ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V}?
Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V} delivers 4,600 W AC at 96.96% CEC efficiency with a 500 V DC ceiling, while ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V} outputs 4,600 W at 240 V.