Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Ginlong Technologies Co Ltd: S6-GC33K-US {480V} — CEC Inverter Specifications

Manufacturer: Ginlong Technologies Co Ltd Registry: CEC Verified Engineering Specification

Ginlong Technologies Co Ltd: S6-GC33K-US {480V} outputs 32,865 W AC at 480 V, 3-phase (39.5 A continuous, 50 A OCPD), ranking #142 of 2,343 CEC inverters at 98.36% efficiency with a 580-850 V MPPT window and 850 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
32,865 W
AC Voltage
480 V, 3-phase
Min PV Breaker
50 A (8 AWG Cu)
CEC Efficiency
98.36%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Ginlong Technologies Co Ltd: S6-GC33K-US {480V} Compare Against Peer CEC Listings?

How Ginlong Technologies Co Ltd Ginlong Technologies Co Ltd: S6-GC33K-US {480V} compares on 98.36% efficiency, MPPT span, and 120% busbar interconnection.

Ginlong Technologies Co Ltd certifies Ginlong Technologies Co Ltd: S6-GC33K-US {480V} (grid-tied PV inverter, active in CEC directory) at 32,865 W AC (17,135 W below the 50,000 W 480 V median). Its 850 V DC ceiling pairs with an MPPT window of 580-850 V (span 270.0 V). Under NEC 690.8/705.12, 125% sizing demands 8 AWG Cu conductors on a 50 A OCPD.

Where Does Ginlong Technologies Co Ltd: S6-GC33K-US {480V} Fall Across Listed CEC Models?

Position of Ginlong Technologies Co Ltd: S6-GC33K-US {480V} (32,865 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Ginlong Technologies Co Ltd: S6-GC33K-US {480V} (32,865 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACGinlong Technologi: 32,865 W

What Dataset Percentiles Define Ginlong Technologies Co Ltd: S6-GC33K-US {480V}?

Percentile placement of Ginlong Technologies Co Ltd: S6-GC33K-US {480V} across AC power class, conversion efficiency, and backfeed breaker size.

Ginlong Technologies Co Ltd: S6-GC33K-US {480V} Technical ThresholdsPercentile comparison for Ginlong Technologies Co Ltd: S6-GC33K-US {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output32,865 WCEC Efficiency98.36%Backfeed Breaker50 A

What Do the Dataset Ranks Show for Ginlong Technologies Co Ltd: S6-GC33K-US {480V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Ginlong Technologies Co Ltd: S6-GC33K-US {480V}.

Eff #142 / 2,343

98.36% CEC Weighted Efficiency

+0.34 pts vs the 98.02% 480 V median; overall power rank #538 (32,865 W, top 23.0%; higher than 77.0% of peers).

NEC 705.12 Check

50 A Required Backfeed OCPD

125% x 39.5 A = 49.4 A -> 50 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

580 V - 850 V (Max 850 V DC)

Tracking span of 270.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 32865.0W / 480 V 3-phase -> 39.5 A | Breaker >= 1.25 * 39.5 = 49.4 A -> 50 A

CEC Inverters.csv for Ginlong Technologies Co Ltd: S6-GC33K-US {480V}: Paco=32865.0 W, Vac=480 V, Vdcmax=850.0 V, Eff=98.36%.

Result: Min 50 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Ginlong Technologies Co Ltd: S6-GC33K-US {480V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Ginlong Technologies Co Ltd: S6-GC33K-US {480V}.

Official California Energy Commission (NREL SAM) test parameters for Ginlong Technologies Co Ltd: S6-GC33K-US {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 32,865 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 850 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 580 V - 850 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 46.4084 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.36% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Ginlong Technologies Co Ltd: S6-GC33K-US {480V} (480 V, 3-phase)?

Check whether Ginlong Technologies Co Ltd: S6-GC33K-US {480V} (50 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Ginlong Technologies Co Ltd: S6-GC33K-US {480V} (50 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 50 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 50 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (480V) 120 A 50 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 50 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 50 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Ginlong Technologies Co Ltd: S6-GC33K-US {480V}?

Verified cold-weather (-10 C) series module counts matched to Ginlong Technologies Co Ltd: S6-GC33K-US {480V}'s 850 V DC ceiling.

Sampled CEC PV modules aligned within 580.0-850.0 V MPPT and 850.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 14 to 15 panels 8.85 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 18 to 20 panels 8.8 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 17 to 18 panels 7.65 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 15 panels (fixed) 7.72 kW

Which Competing Grid-Support Inverters Compare to Ginlong Technologies Co Ltd: S6-GC33K-US {480V}?

Alternative CEC inverters comparable to Ginlong Technologies Co Ltd: S6-GC33K-US {480V}, including CSI Solar Co Ltd: CSI-33K-T480GL03-U {480V} (32,865 W) at 480 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
CSI Solar Co Ltd: CSI-33K-T480GL03-U {480V}
CSI Solar Co Ltd
32,865 W Tie (0 W) 480.0 V 850.0 V 98.36%
Delta Electronics: M28U_120 {480V}
Delta Electronics
30,709 W -2156 W 480.0 V 830.0 V 98.14%
Delta Electronics: M28U_121 {480V}
Delta Electronics
30,709 W -2156 W 480.0 V 830.0 V 98.14%
Delta Electronics: M28U_122 {480V}
Delta Electronics
30,709 W -2156 W 480.0 V 830.0 V 98.14%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Ginlong Technologies Co Ltd: S6-GC33K-US {480V}?

Check Ginlong Technologies Co Ltd: S6-GC33K-US {480V} (32,865 W AC, 50 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 850 V DC on Ginlong Technologies Co Ltd: S6-GC33K-US {480V}.

Ginlong Technologies Co Ltd: S6-GC33K-US {480V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 50 A OCPD breaker (39.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.36%) and MPPT window (580-850 V) directly against CSI Solar Co Ltd: CSI-33K-T480GL03-U {480V} (32,865 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Ginlong Technologies Co Ltd: S6-GC33K-US {480V} by Ginlong Technologies Co Ltd covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does Ginlong Technologies Co Ltd: S6-GC33K-US {480V} require?

At 32,865 W continuous AC (480 V, 3-phase), continuous current is 39.5 A; 125% NEC 690.8/705.12 sizing requires a 50 A breaker and 8 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Ginlong Technologies Co Ltd: S6-GC33K-US {480V} require?

At 32,865 W AC and 480 V, 3-phase, continuous line current is 39.5 A, requiring a 50 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Ginlong Technologies Co Ltd: S6-GC33K-US {480V} compare to CSI Solar Co Ltd: CSI-33K-T480GL03-U {480V}?

Ginlong Technologies Co Ltd: S6-GC33K-US {480V} delivers 32,865 W AC at 98.36% CEC efficiency with a 850 V DC ceiling, while CSI Solar Co Ltd: CSI-33K-T480GL03-U {480V} outputs 32,865 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.