Manufacturer: Ginlong Technologies Co Ltd Registry: CEC Verified Engineering Specification

Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} outputs 29,885 W AC at 480 V, 3-phase (35.9 A continuous, 45 A OCPD), ranking #573 of 2,343 CEC inverters at 97.44% efficiency with a 500-850 V MPPT window and 850 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
29,885 W
AC Voltage
480 V, 3-phase
Min PV Breaker
45 A (8 AWG Cu)
CEC Efficiency
97.44%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V}.

Ranking #567 of 2,343 CEC inverters (top 24.2%; higher than 75.8% of peers), Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} is a hybrid battery-capable inverter delivering 29,885 W continuous AC at 480 V, 3-phase (35.9 A continuous). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 97.44% (-0.58 pts vs the 98.02% 480 V median) against peers like Fortress Power LLC: FP-Nano-30k-N {480V} (29,885 W).

Where Does Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} Fall Across Listed CEC Models?

Marks Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} (29,885 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} (29,885 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACGinlong Technologi: 29,885 W

What Dataset Percentiles Define Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V}?

Benchmarks Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} continuous AC output, 97.44% CEC weighted efficiency, and 45 A OCPD breaker demand.

Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} Technical ThresholdsPercentile comparison for Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output29,885 WCEC Efficiency97.44%Backfeed Breaker45 A

What Do the Dataset Ranks Show for Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V}?

Four key NEC 705.12 and California Energy Commission metrics defining Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} by Ginlong Technologies Co Ltd.

Eff #573 / 2,343

97.44% CEC Weighted Efficiency

-0.58 pts vs the 98.02% 480 V median; overall power rank #567 (29,885 W, top 24.2%; higher than 75.8% of peers).

NEC 705.12 Check

45 A Required Backfeed OCPD

125% x 35.9 A = 44.9 A -> 45 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

500 V - 850 V (Max 850 V DC)

Tracking span of 350.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 29884.7W / 480 V 3-phase -> 35.9 A | Breaker >= 1.25 * 35.9 = 44.9 A -> 45 A

CEC Inverters.csv for Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V}: Paco=29884.7 W, Vac=480 V, Vdcmax=850.0 V, Eff=97.44%.

Result: Min 45 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V}.

Official California Energy Commission (NREL SAM) test parameters for Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 29,885 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 850 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 500 V - 850 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 45.439 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.44% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} (480 V, 3-phase)?

Evaluates Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} (45 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} (45 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 45 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 45 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (480V) 120 A 45 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 45 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 45 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V}?

Sample PV string lengths aligned within 500-850 V MPPT and 850 V DC max at -10 C. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sampled CEC PV modules aligned within 500.0-850.0 V MPPT and 850.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 12 to 15 panels 8.85 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 15 to 20 panels 8.8 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 15 to 18 panels 7.65 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 18 to 20 panels 4.0 kW

Which Competing Grid-Support Inverters Compare to Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V}?

Competing CEC grid-support inverters near 29,885 W AC and 480 V, 3-phase, led by Fortress Power LLC: FP-Nano-30k-N {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Fortress Power LLC: FP-Nano-30k-N {480V}
Fortress Power LLC
29,885 W Tie (0 W) 480.0 V 850.0 V 97.44%
CSI Solar Co Ltd: CSI-30K-T480GL03-U {480V}
CSI Solar Co Ltd
29,883 W -2 W 480.0 V 850.0 V 98.28%
CSI Solar Co Ltd: CSI-30K-T480GL01-UB {480V}
CSI Solar Co Ltd
29,948 W +63 W 480.0 V 800.0 V 98.34%
CE+T America Inc: 30C {480V}
CE+T America Inc
29,990 W +105 W 480.0 V 850.0 V 95.24%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V}?

Check Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} (29,885 W AC, 45 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 850 V DC on Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V}.

Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 45 A OCPD breaker (35.9 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.44%) and MPPT window (500-850 V) directly against Fortress Power LLC: FP-Nano-30k-N {480V} (29,885 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} by Ginlong Technologies Co Ltd covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} require?

At 29,885 W continuous AC (480 V, 3-phase), continuous current is 35.9 A; 125% NEC 690.8/705.12 sizing requires a 45 A breaker and 8 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} require?

At 29,885 W AC and 480 V, 3-phase, continuous line current is 35.9 A, requiring a 45 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} compare to Fortress Power LLC: FP-Nano-30k-N {480V}?

Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V} delivers 29,885 W AC at 97.44% CEC efficiency with a 850 V DC ceiling, while Fortress Power LLC: FP-Nano-30k-N {480V} outputs 29,885 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.