Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Geneverse Energy Inc: GVI-HS-6K-USM {240V} — CEC Inverter Specifications

Manufacturer: Geneverse Energy Inc Registry: CEC Verified Engineering Specification

Geneverse Energy Inc: GVI-HS-6K-USM {240V} outputs 6,117 W AC at 240 V (25.5 A continuous, 35 A OCPD), ranking #856 of 2,343 CEC inverters at 97.13% efficiency with a 200-430 V MPPT window and 430 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
6,117 W
AC Voltage
240 V
Min PV Breaker
35 A (8 AWG Cu)
CEC Efficiency
97.13%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Geneverse Energy Inc: GVI-HS-6K-USM {240V} Compare Against Peer CEC Listings?

Breaker sizing (35 A), 8 AWG Cu wire rules, and DC input limits for Geneverse Energy Inc: GVI-HS-6K-USM {240V}.

Classified as a hybrid battery-capable inverter (active in CEC directory), Geneverse Energy Inc: GVI-HS-6K-USM {240V} requires 31.9 A design capacity -> 35 A breaker using 8 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 97.13% (+0.31 pts vs overall CEC median) across 2,343 CEC models, while requires a 35 a breaker, passing directly inside a standard 200 a main / 200 a busbar panel (40 a limit).

Where Does Geneverse Energy Inc: GVI-HS-6K-USM {240V} Fall Across Listed CEC Models?

Output power comparison showing where Geneverse Energy Inc: GVI-HS-6K-USM {240V} sits among all 2,343 CEC-listed grid-support inverters. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Geneverse Energy Inc: GVI-HS-6K-USM {240V} (6,117 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACGeneverse Energy I: 6,117 W

What Dataset Percentiles Define Geneverse Energy Inc: GVI-HS-6K-USM {240V}?

Relative ranking of Geneverse Energy Inc: GVI-HS-6K-USM {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Geneverse Energy Inc: GVI-HS-6K-USM {240V} Technical ThresholdsPercentile comparison for Geneverse Energy Inc: GVI-HS-6K-USM {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output6,117 WCEC Efficiency97.13%Backfeed Breaker35 A

What Do the Dataset Ranks Show for Geneverse Energy Inc: GVI-HS-6K-USM {240V}?

Snapshot of Geneverse Energy Inc: GVI-HS-6K-USM {240V} efficiency rank (#856), OCPD breaker size, MPPT span, and busbar verdict.

Eff #856 / 2,343

97.13% CEC Weighted Efficiency

+0.45 pts vs the 96.68% 240 V median; overall power rank #1,354 (6,117 W, below CEC median; higher than 42.2% of peers).

NEC 705.12 Check

35 A Required Backfeed OCPD

125% x 25.5 A = 31.9 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

200 V - 430 V (Max 430 V DC)

Tracking span of 230.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 6117.2W / 240 V -> 25.5 A | Breaker >= 1.25 * 25.5 = 31.9 A -> 35 A

CEC Inverters.csv for Geneverse Energy Inc: GVI-HS-6K-USM {240V}: Paco=6117.2 W, Vac=240 V, Vdcmax=430.0 V, Eff=97.13%.

Result: Min 35 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Geneverse Energy Inc: GVI-HS-6K-USM {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Geneverse Energy Inc: GVI-HS-6K-USM {240V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Geneverse Energy Inc: GVI-HS-6K-USM {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 6,117 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 430 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 200 V - 430 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 17.4942 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.13% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Geneverse Energy Inc: GVI-HS-6K-USM {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Geneverse Energy Inc: GVI-HS-6K-USM {240V} at 240 V. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Evaluates Geneverse Energy Inc: GVI-HS-6K-USM {240V} (35 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 35 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 35 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 35 A PASS (120% Rule)
200A Bus / 175A Main 65 A 35 A PASS (120% Rule)
225A Bus / 200A Main 70 A 35 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Geneverse Energy Inc: GVI-HS-6K-USM {240V}?

Minimum and maximum series solar module strings fitting Geneverse Energy Inc: GVI-HS-6K-USM {240V} MPPT and 430 V limits.

Sampled CEC PV modules aligned within 200.0-430.0 V MPPT and 430.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 7 panels 4.13 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 10 panels 4.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 9 panels 3.83 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 10 panels 2.0 kW

Which Competing Grid-Support Inverters Compare to Geneverse Energy Inc: GVI-HS-6K-USM {240V}?

Peer 240 V CEC inverters near 6,117 W AC output such as Amensolar Ess Co Ltd: N3H-X60-US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Amensolar Ess Co Ltd: N3H-X60-US {240V}
Amensolar Ess Co Ltd
6,117 W Tie (0 W) 240.0 V 430.0 V 97.13%
Anker Innovations Limited: X1-P6K-US {240V}
Anker Innovations Limited
6,040 W -77 W 240.0 V 450.0 V 97.43%
Dyness Digital Energy Technology Co LTD: TX6K-AM {240V}
Dyness Digital Energy Technology Co LTD
6,028 W -89 W 240.0 V 490.0 V 96.68%
Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}
Dyness Digital Energy Technology Co LTD
6,018 W -99 W 240.0 V 500.0 V 97.0%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Geneverse Energy Inc: GVI-HS-6K-USM {240V}?

Check Geneverse Energy Inc: GVI-HS-6K-USM {240V} (6,117 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 430 V DC on Geneverse Energy Inc: GVI-HS-6K-USM {240V}.

Geneverse Energy Inc: GVI-HS-6K-USM {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (25.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.13%) and MPPT window (200-430 V) directly against Amensolar Ess Co Ltd: N3H-X60-US {240V} (6,117 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Geneverse Energy Inc: GVI-HS-6K-USM {240V} by Geneverse Energy Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Geneverse Energy Inc: GVI-HS-6K-USM {240V} require?

At 6,117 W continuous AC (240 V), continuous current is 25.5 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

Does Geneverse Energy Inc: GVI-HS-6K-USM {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 35 A at 240 V means PASS (120% Rule).

How does Geneverse Energy Inc: GVI-HS-6K-USM {240V} compare to Amensolar Ess Co Ltd: N3H-X60-US {240V}?

Geneverse Energy Inc: GVI-HS-6K-USM {240V} delivers 6,117 W AC at 97.13% CEC efficiency with a 430 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X60-US {240V} outputs 6,117 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.