Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} — CEC Inverter Specifications

Manufacturer: Dyness Digital Energy Technology Co LTD Registry: CEC Verified Engineering Specification

Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} outputs 6,018 W AC at 240 V (25.1 A continuous, 35 A OCPD), ranking #1,014 of 2,343 CEC inverters at 97.0% efficiency with a 210-500 V MPPT window and 500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
6,018 W
AC Voltage
240 V
Min PV Breaker
35 A (8 AWG Cu)
CEC Efficiency
97.0%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} Compare Against Peer CEC Listings?

Breaker sizing (35 A), 8 AWG Cu wire rules, and DC input limits for Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}.

Classified as a hybrid battery-capable inverter (listed since 2024-01-22), Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} requires 31.4 A design capacity -> 35 A breaker using 8 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 97.0% (+0.18 pts vs overall CEC median) across 2,343 CEC models, while requires a 35 a breaker, passing directly inside a standard 200 a main / 200 a busbar panel (40 a limit).

Where Does Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} Fall Across Listed CEC Models?

Output power comparison showing where Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} (6,018 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACDyness Digital Ene: 6,018 W

What Dataset Percentiles Define Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}?

Relative ranking of Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} Technical ThresholdsPercentile comparison for Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output6,018 WCEC Efficiency97.0%Backfeed Breaker35 A

What Do the Dataset Ranks Show for Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}?

Snapshot of Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} efficiency rank (#1,014), OCPD breaker size, MPPT span, and busbar verdict.

Eff #1,014 / 2,343

97.0% CEC Weighted Efficiency

+0.32 pts vs the 96.68% 240 V median; overall power rank #1,375 (6,018 W, below CEC median; higher than 41.3% of peers).

NEC 705.12 Check

35 A Required Backfeed OCPD

125% x 25.1 A = 31.4 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

210 V - 500 V (Max 500 V DC)

Tracking span of 290.0 V; listed since 2024-01-22 (hybrid battery-capable inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 6018.0W / 240 V -> 25.1 A | Breaker >= 1.25 * 25.1 = 31.4 A -> 35 A

CEC Inverters.csv for Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}: Paco=6018.0 W, Vac=240 V, Vdcmax=500.0 V, Eff=97.0%.

Result: Min 35 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}.

Official California Energy Commission (NREL SAM) test parameters for Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 6,018 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 210 V - 500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 15.9077 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.0% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2024-01-22 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} at 240 V.

Evaluates Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} (35 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 35 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 35 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 35 A PASS (120% Rule)
200A Bus / 175A Main 65 A 35 A PASS (120% Rule)
225A Bus / 200A Main 70 A 35 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}?

Minimum and maximum series solar module strings fitting Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} MPPT and 500 V limits.

Sampled CEC PV modules aligned within 210.0-500.0 V MPPT and 500.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 7 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 7 to 11 panels 4.67 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 8 to 12 panels 2.4 kW

Which Competing Grid-Support Inverters Compare to Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}?

Peer 240 V CEC inverters near 6,018 W AC output such as ABB: PVI-6000-OUTD-US-A {240V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: PVI-6000-OUTD-US-A {240V}
ABB
6,000 W -18 W 240.0 V 480.0 V 96.21%
ABB: PVI-6000-OUTD-US-Z-A {240V}
ABB
6,000 W -18 W 240.0 V 480.0 V 96.21%
ABB: PVI-6000-OUTD-US-Z-M-A {240V}
ABB
6,000 W -18 W 240.0 V 480.0 V 96.21%
ABB: UNO-DM-60-TL-PLUS-US-S-XRA {240V}
ABB
6,000 W -18 W 240.0 V 480.0 V 97.03%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}?

Check Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} (6,018 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 500 V DC on Dyness Digital Energy Technology Co LTD: TX6K-HM {240V}.

Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (25.1 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.0%) and MPPT window (210-500 V) directly against ABB: PVI-6000-OUTD-US-A {240V} (6,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} by Dyness Digital Energy Technology Co LTD covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} require?

At 6,018 W continuous AC (240 V), continuous current is 25.1 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

Does Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 35 A at 240 V means PASS (120% Rule).

How does Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} compare to ABB: PVI-6000-OUTD-US-A {240V}?

Dyness Digital Energy Technology Co LTD: TX6K-HM {240V} delivers 6,018 W AC at 97.0% CEC efficiency with a 500 V DC ceiling, while ABB: PVI-6000-OUTD-US-A {240V} outputs 6,000 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.