Fronius International GmbH: Primo GEN24 100 208-240 {208V} — CEC Inverter Specifications

Manufacturer: Fronius International GmbH Registry: CEC Verified Engineering Specification

Fronius International GmbH: Primo GEN24 100 208-240 {208V} outputs 9,454 W AC at 208 V, commercial single-phase (45.5 A continuous, 60 A OCPD), ranking #1,652 of 2,343 CEC inverters at 96.41% efficiency with a 260-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
9,454 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
60 A (6 AWG Cu)
CEC Efficiency
96.41%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Fronius International GmbH: Primo GEN24 100 208-240 {208V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 208 V, commercial single-phase grid-support overview for Fronius International GmbH: Primo GEN24 100 208-240 {208V}.

Rated at 9,454 W AC (45.5 A continuous), Fronius International GmbH: Primo GEN24 100 208-240 {208V} ranks #1,652 of 2,343 CEC units at 96.41% efficiency (equal to the 96.41% 208 V median). Minimum 75 C copper conductor sizing for its 60 A circuit is 6 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 480 V DC at record local winter lows.

Where Does Fronius International GmbH: Primo GEN24 100 208-240 {208V} Fall Across Listed CEC Models?

Marks Fronius International GmbH: Primo GEN24 100 208-240 {208V} (9,454 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Fronius International GmbH: Primo GEN24 100 208-240 {208V} (9,454 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACFronius Internatio: 9,454 W

What Dataset Percentiles Define Fronius International GmbH: Primo GEN24 100 208-240 {208V}?

Benchmarks Fronius International GmbH: Primo GEN24 100 208-240 {208V} continuous AC output, 96.41% CEC weighted efficiency, and 60 A OCPD breaker demand.

Fronius International GmbH: Primo GEN24 100 208-240 {208V} Technical ThresholdsPercentile comparison for Fronius International GmbH: Primo GEN24 100 208-240 {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output9,454 WCEC Efficiency96.41%Backfeed Breaker60 A

What Do the Dataset Ranks Show for Fronius International GmbH: Primo GEN24 100 208-240 {208V}?

Four key NEC 705.12 and California Energy Commission metrics defining Fronius International GmbH: Primo GEN24 100 208-240 {208V} by Fronius International GmbH.

Eff #1,652 / 2,343

96.41% CEC Weighted Efficiency

equal to the 96.41% 208 V median; overall power rank #1,002 (9,454 W, top 42.8%; higher than 57.2% of peers).

NEC 705.12 Check

60 A Required Backfeed OCPD

125% x 45.5 A = 56.9 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

260 V - 480 V (Max 480 V DC)

Tracking span of 220.0 V; listed since 2025-05-01 (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 9454.0W / 208 V -> 45.5 A | Breaker >= 1.25 * 45.5 = 56.9 A -> 60 A

CEC Inverters.csv for Fronius International GmbH: Primo GEN24 100 208-240 {208V}: Paco=9454.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=96.41%.

Result: Min 60 A breaker & 6 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Fronius International GmbH: Primo GEN24 100 208-240 {208V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Fronius International GmbH: Primo GEN24 100 208-240 {208V}.

Official California Energy Commission (NREL SAM) test parameters for Fronius International GmbH: Primo GEN24 100 208-240 {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 9,454 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 260 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 26.8662 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.41% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-05-01 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

What Switchgear Limits Apply to Fronius International GmbH: Primo GEN24 100 208-240 {208V} (208 V, commercial single-phase)?

Evaluates Fronius International GmbH: Primo GEN24 100 208-240 {208V} (60 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Fronius International GmbH: Primo GEN24 100 208-240 {208V} (60 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 60 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (208V) 80 A 60 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 60 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 60 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 60 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Fronius International GmbH: Primo GEN24 100 208-240 {208V}?

Sample PV string lengths aligned within 260-480 V MPPT and 480 V DC max at -10 C. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sampled CEC PV modules aligned within 260.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 7 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 8 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 8 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 9 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Fronius International GmbH: Primo GEN24 100 208-240 {208V}?

Competing CEC grid-support inverters near 9,454 W AC and 208 V, commercial single-phase, led by Chint Power Systems America: CPS ECH96KTL/US {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Chint Power Systems America: CPS ECH96KTL/US {208V}
Chint Power Systems America
9,550 W +96 W 208.0 V 480.0 V 96.73%
Altenergy Power System Inc: ELS-114 {208V}
Altenergy Power System Inc
10,011 W +557 W 208.0 V 60.0 V 92.83%
Delta Electronics: S12_BDI {208V}
Delta Electronics
10,057 W +603 W 208.0 V 480.0 V 96.7%
EG4 Electronics LLC: 18KPV-12LV {208V}
EG4 Electronics LLC
10,499 W +1045 W 208.0 V 480.0 V 96.07%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Fronius International GmbH: Primo GEN24 100 208-240 {208V}?

Check Fronius International GmbH: Primo GEN24 100 208-240 {208V} (9,454 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Fronius International GmbH: Primo GEN24 100 208-240 {208V}.

Fronius International GmbH: Primo GEN24 100 208-240 {208V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (45.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.41%) and MPPT window (260-480 V) directly against Chint Power Systems America: CPS ECH96KTL/US {208V} (9,550 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Fronius International GmbH: Primo GEN24 100 208-240 {208V} by Fronius International GmbH covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Fronius International GmbH: Primo GEN24 100 208-240 {208V} require?

At 9,454 W continuous AC (208 V, commercial single-phase), continuous current is 45.5 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Fronius International GmbH: Primo GEN24 100 208-240 {208V} require?

At 9,454 W AC and 208 V, commercial single-phase, continuous line current is 45.5 A, requiring a 60 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Fronius International GmbH: Primo GEN24 100 208-240 {208V} compare to Chint Power Systems America: CPS ECH96KTL/US {208V}?

Fronius International GmbH: Primo GEN24 100 208-240 {208V} delivers 9,454 W AC at 96.41% CEC efficiency with a 480 V DC ceiling, while Chint Power Systems America: CPS ECH96KTL/US {208V} outputs 9,550 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.