Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} outputs 12,000 W AC at 208 V, 3-phase (33.3 A continuous, 45 A OCPD), ranking #2,071 of 2,343 CEC inverters at 95.81% efficiency with a 300-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 12,000 W
- AC Voltage
- 208 V, 3-phase
- Min PV Breaker
- 45 A (8 AWG Cu)
- CEC Efficiency
- 95.81%
How Does Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} Compare Against Peer CEC Listings?
How Fronius International GmbH Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} compares on 95.81% efficiency, MPPT span, and 120% busbar interconnection.
With a 300-480 V MPPT tracking band and 480 V DC ceiling, Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} handles 12,000 W continuous AC (7,000 W above the 5,000 W 208 V median). Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap. Installers comparing Fronius International GmbH against Chint Power Systems America: CPS ECH12KTL/US {208V} (12,000 W) should verify whether listed since 2019-03-01 grid-support firmware meets local IEEE 1547 utility rules.
Where Does Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} Fall Across Listed CEC Models?
Position of Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} (12,000 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}?
Percentile placement of Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}.
95.81% CEC Weighted Efficiency
-0.60 pts vs the 96.41% 208 V median; overall power rank #723 (12,000 W, top 31.1%; higher than 68.9% of peers).
45 A Required Backfeed OCPD
125% x 33.3 A = 41.6 A -> 45 A standard OCPD using 8 AWG Cu (75 C).
300 V - 480 V (Max 480 V DC)
Tracking span of 180.0 V; listed since 2019-03-01 (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 12000.0W / 208 V 3-phase -> 33.3 A | Breaker >= 1.25 * 33.3 = 41.6 A -> 45 A
CEC Inverters.csv for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}: Paco=12000.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=95.81%.
Result: Min 45 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 12,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 300 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 35.7863 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 95.81% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2019-03-01 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} (208 V, 3-phase)?
Check whether Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} (45 A breaker) fits without main breaker derate or supply-side taps.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 45 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (208V) | 80 A | 45 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 45 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 45 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 45 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}?
Verified cold-weather (-10 C) series module counts matched to Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}'s 480 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 7 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 9 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 9 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 11 panels (fixed) | 2.2 kW |
Which Competing Grid-Support Inverters Compare to Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}?
Alternative CEC inverters comparable to Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}, including Chint Power Systems America: CPS ECH12KTL/US {208V} (12,000 W) at 208 V, 3-phase.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Chint Power Systems America: CPS ECH12KTL/US {208V} Chint Power Systems America |
12,000 W | Tie (0 W) | 208.0 V | 480.0 V | 96.63% |
| EcoFlow Inc: EF-PCS-24 {208V 115kW} EcoFlow Inc |
11,444 W | -556 W | 208.0 V | 480.0 V | 96.52% |
| Chint Power Systems America: CPS ECH114KTL/US {208V} Chint Power Systems America |
11,350 W | -650 W | 208.0 V | 480.0 V | 96.63% |
| EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V} EG4 Electronics LLC |
11,325 W | -675 W | 208.0 V | 440.0 V | 96.79% |
What Are the Interconnection Limits and Best-Fit Uses for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}?
Check Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} (12,000 W AC, 45 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Fronius International GmbH: Fronius Symo 120-3 208-240 {208V}.
Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 45 A OCPD breaker (33.3 A continuous).
Alternative Inverter Comparison
Compare efficiency (95.81%) and MPPT window (300-480 V) directly against Chint Power Systems America: CPS ECH12KTL/US {208V} (12,000 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} by Fronius International GmbH covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.
What breaker and wire size does Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} require?
At 12,000 W continuous AC (208 V, 3-phase), continuous current is 33.3 A; 125% NEC 690.8/705.12 sizing requires a 45 A breaker and 8 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} require?
At 12,000 W AC and 208 V, 3-phase, continuous line current is 33.3 A, requiring a 45 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} compare to Chint Power Systems America: CPS ECH12KTL/US {208V}?
Fronius International GmbH: Fronius Symo 120-3 208-240 {208V} delivers 12,000 W AC at 95.81% CEC efficiency with a 480 V DC ceiling, while Chint Power Systems America: CPS ECH12KTL/US {208V} outputs 12,000 W at 208 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)