Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} — CEC Inverter Specifications

Manufacturer: Fronius International GmbH Registry: CEC Verified Engineering Specification

Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} outputs 5,000 W AC at 240 V (20.8 A continuous, 30 A OCPD), ranking #563 of 2,343 CEC inverters at 97.46% efficiency with a 100-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
5,000 W
AC Voltage
240 V
Min PV Breaker
30 A (10 AWG Cu)
CEC Efficiency
97.46%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Fronius International GmbH: Fronius Primo 50-1 208-240 {240V}.

Ranking #1,516 of 2,343 CEC inverters (below CEC median; higher than 33.9% of peers), Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} is a grid-tied PV inverter delivering 5,000 W continuous AC at 240 V (20.8 A continuous). Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Weighted CEC efficiency reaches 97.46% (+0.78 pts vs the 96.68% 240 V median) against peers like ABB: PVI-5000-OUTD-US-A {240V} (5,000 W).

Where Does Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} Fall Across Listed CEC Models?

Marks Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} (5,000 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} (5,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACFronius Internatio: 5,000 W

What Dataset Percentiles Define Fronius International GmbH: Fronius Primo 50-1 208-240 {240V}?

Benchmarks Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} continuous AC output, 97.46% CEC weighted efficiency, and 30 A OCPD breaker demand.

Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} Technical ThresholdsPercentile comparison for Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output5,000 WCEC Efficiency97.46%Backfeed Breaker30 A

What Do the Dataset Ranks Show for Fronius International GmbH: Fronius Primo 50-1 208-240 {240V}?

Four key NEC 705.12 and California Energy Commission metrics defining Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} by Fronius International GmbH.

Eff #563 / 2,343

97.46% CEC Weighted Efficiency

+0.78 pts vs the 96.68% 240 V median; overall power rank #1,516 (5,000 W, below CEC median; higher than 33.9% of peers).

NEC 705.12 Check

30 A Required Backfeed OCPD

125% x 20.8 A = 26.0 A -> 30 A standard OCPD using 10 AWG Cu (75 C).

MPPT Window

100 V - 800 V (Max 800 V DC)

Tracking span of 700.0 V; listed since 2019-03-01 (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 5000.0W / 240 V -> 20.8 A | Breaker >= 1.25 * 20.8 = 26.0 A -> 30 A

CEC Inverters.csv for Fronius International GmbH: Fronius Primo 50-1 208-240 {240V}: Paco=5000.0 W, Vac=240 V, Vdcmax=800.0 V, Eff=97.46%.

Result: Min 30 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Fronius International GmbH: Fronius Primo 50-1 208-240 {240V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Fronius International GmbH: Fronius Primo 50-1 208-240 {240V}.

Official California Energy Commission (NREL SAM) test parameters for Fronius International GmbH: Fronius Primo 50-1 208-240 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 5,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 800 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 100 V - 800 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 7.77316 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.46% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2019-03-01 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Fronius International GmbH: Fronius Primo 50-1 208-240 {240V}?

Evaluates Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} (30 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} (30 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 30 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 30 A PASS (120% Rule)
200A Bus / 200A Main 40 A 30 A PASS (120% Rule)
200A Bus / 175A Main 65 A 30 A PASS (120% Rule)
225A Bus / 200A Main 70 A 30 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Fronius International GmbH: Fronius Primo 50-1 208-240 {240V}?

Sample PV string lengths aligned within 100-800 V MPPT and 800 V DC max at -10 C. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sampled CEC PV modules aligned within 100.0-800.0 V MPPT and 800.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 3 to 14 panels 8.26 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 3 to 18 panels 7.92 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 3 to 17 panels 7.22 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 4 to 19 panels 3.8 kW

Which Competing Grid-Support Inverters Compare to Fronius International GmbH: Fronius Primo 50-1 208-240 {240V}?

Competing CEC grid-support inverters near 5,000 W AC and 240 V, led by ABB: PVI-5000-OUTD-US-A {240V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: PVI-5000-OUTD-US-A {240V}
ABB
5,000 W Tie (0 W) 240.0 V 480.0 V 96.33%
ABB: PVI-5000-OUTD-US-Z-A {240V}
ABB
5,000 W Tie (0 W) 240.0 V 480.0 V 96.33%
ABB: PVI-5000-OUTD-US-Z-M-A {240V}
ABB
5,000 W Tie (0 W) 240.0 V 480.0 V 96.33%
ABB: UNO-DM-50-TL-PLUS-US-SB-RA {240V}
ABB
5,000 W Tie (0 W) 240.0 V 480.0 V 96.65%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Fronius International GmbH: Fronius Primo 50-1 208-240 {240V}?

Check Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} (5,000 W AC, 30 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on Fronius International GmbH: Fronius Primo 50-1 208-240 {240V}.

Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} Panel & Wire Spec

Size 75 C copper conductors at 10 AWG Cu on a 30 A OCPD breaker (20.8 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.46%) and MPPT window (100-800 V) directly against ABB: PVI-5000-OUTD-US-A {240V} (5,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} by Fronius International GmbH covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} require?

At 5,000 W continuous AC (240 V), continuous current is 20.8 A; 125% NEC 690.8/705.12 sizing requires a 30 A breaker and 10 AWG Cu (75 C) wire.

Does Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 30 A at 240 V means PASS (120% Rule).

How does Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} compare to ABB: PVI-5000-OUTD-US-A {240V}?

Fronius International GmbH: Fronius Primo 50-1 208-240 {240V} delivers 5,000 W AC at 97.46% CEC efficiency with a 800 V DC ceiling, while ABB: PVI-5000-OUTD-US-A {240V} outputs 5,000 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.