Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

FOXESS CO LTD: AC1-76-US {240V} — CEC Inverter Specifications

Manufacturer: FOXESS CO LTD Registry: CEC Verified Engineering Specification

FOXESS CO LTD: AC1-76-US {240V} outputs 7,564 W AC at 240 V (31.5 A continuous, 40 A OCPD), ranking #822 of 2,343 CEC inverters at 97.15% efficiency with a 190-460 V MPPT window and 460 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
7,564 W
AC Voltage
240 V
Min PV Breaker
40 A (8 AWG Cu)
CEC Efficiency
97.15%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does FOXESS CO LTD: AC1-76-US {240V} Compare Against Peer CEC Listings?

Breaker sizing (40 A), 8 AWG Cu wire rules, and DC input limits for FOXESS CO LTD: AC1-76-US {240V}.

For NEC 705.12 solar interconnection, FOXESS CO LTD: AC1-76-US {240V} outputs 31.5 A continuous AC at 240 V and needs a 40 A backfeed breaker on 8 AWG Cu (75 C). Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Conversion efficiency scores 97.15% (#822 of 2,343, +0.33 pts vs overall CEC median).

Where Does FOXESS CO LTD: AC1-76-US {240V} Fall Across Listed CEC Models?

Output power comparison showing where FOXESS CO LTD: AC1-76-US {240V} sits among all 2,343 CEC-listed grid-support inverters. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where FOXESS CO LTD: AC1-76-US {240V} (7,564 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACFOXESS CO LTD: AC1: 7,564 W

What Dataset Percentiles Define FOXESS CO LTD: AC1-76-US {240V}?

Relative ranking of FOXESS CO LTD: AC1-76-US {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

FOXESS CO LTD: AC1-76-US {240V} Technical ThresholdsPercentile comparison for FOXESS CO LTD: AC1-76-US {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output7,564 WCEC Efficiency97.15%Backfeed Breaker40 A

What Do the Dataset Ranks Show for FOXESS CO LTD: AC1-76-US {240V}?

Snapshot of FOXESS CO LTD: AC1-76-US {240V} efficiency rank (#822), OCPD breaker size, MPPT span, and busbar verdict.

Eff #822 / 2,343

97.15% CEC Weighted Efficiency

+0.47 pts vs the 96.68% 240 V median; overall power rank #1,268 (7,564 W, below CEC median; higher than 45.9% of peers).

NEC 705.12 Check

40 A Required Backfeed OCPD

125% x 31.5 A = 39.4 A -> 40 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

190 V - 460 V (Max 460 V DC)

Tracking span of 270.0 V; listed since 2024-02-12 (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 7564.1W / 240 V -> 31.5 A | Breaker >= 1.25 * 31.5 = 39.4 A -> 40 A

CEC Inverters.csv for FOXESS CO LTD: AC1-76-US {240V}: Paco=7564.1 W, Vac=240 V, Vdcmax=460.0 V, Eff=97.15%.

Result: Min 40 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for FOXESS CO LTD: AC1-76-US {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for FOXESS CO LTD: AC1-76-US {240V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for FOXESS CO LTD: AC1-76-US {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 7,564 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 460 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 190 V - 460 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 21.6279 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.15% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2024-02-12 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for FOXESS CO LTD: AC1-76-US {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for FOXESS CO LTD: AC1-76-US {240V} at 240 V. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Evaluates FOXESS CO LTD: AC1-76-US {240V} (40 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 40 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 40 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 40 A PASS (120% Rule)
200A Bus / 175A Main 65 A 40 A PASS (120% Rule)
225A Bus / 200A Main 70 A 40 A PASS (120% Rule)

Which CEC PV Module Strings Pair With FOXESS CO LTD: AC1-76-US {240V}?

Minimum and maximum series solar module strings fitting FOXESS CO LTD: AC1-76-US {240V} MPPT and 460 V limits.

Sampled CEC PV modules aligned within 190.0-460.0 V MPPT and 460.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 10 panels 4.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to FOXESS CO LTD: AC1-76-US {240V}?

Peer 240 V CEC inverters near 7,564 W AC output such as Chint Power Systems America: CPS ECH76KTL/US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Chint Power Systems America: CPS ECH76KTL/US {240V}
Chint Power Systems America
7,570 W +6 W 240.0 V 480.0 V 96.71%
Afore New Energy Technology (Shanghai) Co Ltd: AF76K-DH {240V}
Afore New Energy Technology (Shanghai) Co Ltd
7,599 W +35 W 240.0 V 480.0 V 97.57%
ABB: UNO-76-TL-OUTD-S-US-A {240V}
ABB
7,600 W +36 W 240.0 V 480.0 V 97.05%
ABB: UNO-76-TL-OUTD-S-US-Z-A {240V}
ABB
7,600 W +36 W 240.0 V 480.0 V 97.05%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for FOXESS CO LTD: AC1-76-US {240V}?

Check FOXESS CO LTD: AC1-76-US {240V} (7,564 W AC, 40 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 460 V DC on FOXESS CO LTD: AC1-76-US {240V}.

FOXESS CO LTD: AC1-76-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 40 A OCPD breaker (31.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.15%) and MPPT window (190-460 V) directly against Chint Power Systems America: CPS ECH76KTL/US {240V} (7,570 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for FOXESS CO LTD: AC1-76-US {240V} by FOXESS CO LTD covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does FOXESS CO LTD: AC1-76-US {240V} require?

At 7,564 W continuous AC (240 V), continuous current is 31.5 A; 125% NEC 690.8/705.12 sizing requires a 40 A breaker and 8 AWG Cu (75 C) wire.

Does FOXESS CO LTD: AC1-76-US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 40 A at 240 V means PASS (120% Rule).

How does FOXESS CO LTD: AC1-76-US {240V} compare to Chint Power Systems America: CPS ECH76KTL/US {240V}?

FOXESS CO LTD: AC1-76-US {240V} delivers 7,564 W AC at 97.15% CEC efficiency with a 460 V DC ceiling, while Chint Power Systems America: CPS ECH76KTL/US {240V} outputs 7,570 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.