Fortress Power LLC: Avalon HV PC76 {240V} outputs 7,604 W AC at 240 V (31.7 A continuous, 40 A OCPD), ranking #595 of 2,343 CEC inverters at 97.41% efficiency with a 175-450 V MPPT window and 450 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 7,604 W
- AC Voltage
- 240 V
- Min PV Breaker
- 40 A (8 AWG Cu)
- CEC Efficiency
- 97.41%
How Does Fortress Power LLC: Avalon HV PC76 {240V} Compare Against Peer CEC Listings?
How Fortress Power LLC Fortress Power LLC: Avalon HV PC76 {240V} compares on 97.41% efficiency, MPPT span, and 120% busbar interconnection.
Fortress Power LLC certifies Fortress Power LLC: Avalon HV PC76 {240V} (hybrid battery-capable inverter, active in CEC directory) at 7,604 W AC (1,828 W above the 5,776 W 240 V median). Its 450 V DC ceiling pairs with an MPPT window of 175-450 V (span 275.0 V). Under NEC 690.8/705.12, 125% sizing demands 8 AWG Cu conductors on a 40 A OCPD.
Where Does Fortress Power LLC: Avalon HV PC76 {240V} Fall Across Listed CEC Models?
Position of Fortress Power LLC: Avalon HV PC76 {240V} (7,604 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define Fortress Power LLC: Avalon HV PC76 {240V}?
Percentile placement of Fortress Power LLC: Avalon HV PC76 {240V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for Fortress Power LLC: Avalon HV PC76 {240V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Fortress Power LLC: Avalon HV PC76 {240V}.
97.41% CEC Weighted Efficiency
+0.73 pts vs the 96.68% 240 V median; overall power rank #1,219 (7,604 W, below CEC median; higher than 48.0% of peers).
40 A Required Backfeed OCPD
125% x 31.7 A = 39.6 A -> 40 A standard OCPD using 8 AWG Cu (75 C).
175 V - 450 V (Max 450 V DC)
Tracking span of 275.0 V; active in CEC directory (hybrid battery-capable inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 7604.3W / 240 V -> 31.7 A | Breaker >= 1.25 * 31.7 = 39.6 A -> 40 A
CEC Inverters.csv for Fortress Power LLC: Avalon HV PC76 {240V}: Paco=7604.3 W, Vac=240 V, Vdcmax=450.0 V, Eff=97.41%.
Result: Min 40 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for Fortress Power LLC: Avalon HV PC76 {240V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Fortress Power LLC: Avalon HV PC76 {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 7,604 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 450 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 175 V - 450 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 20.5431 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.41% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for Fortress Power LLC: Avalon HV PC76 {240V}?
Check whether Fortress Power LLC: Avalon HV PC76 {240V} (40 A breaker) fits without main breaker derate or supply-side taps.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 40 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 40 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 40 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 40 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 40 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Fortress Power LLC: Avalon HV PC76 {240V}?
Verified cold-weather (-10 C) series module counts matched to Fortress Power LLC: Avalon HV PC76 {240V}'s 450 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 5 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 6 to 10 panels | 4.4 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 6 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 7 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to Fortress Power LLC: Avalon HV PC76 {240V}?
Alternative CEC inverters comparable to Fortress Power LLC: Avalon HV PC76 {240V}, including ABB: UNO-76-TL-OUTD-S-US-A {240V} (7,600 W) at 240 V.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| ABB: UNO-76-TL-OUTD-S-US-A {240V} ABB |
7,600 W | -4 W | 240.0 V | 480.0 V | 97.05% |
| ABB: UNO-76-TL-OUTD-S-US-Z-A {240V} ABB |
7,600 W | -4 W | 240.0 V | 480.0 V | 97.05% |
| ABB: UNO-76-TL-OUTD-S-US-Z-M-A {240V} ABB |
7,600 W | -4 W | 240.0 V | 480.0 V | 97.05% |
| Delta Electronics: SOLIVIA 76 NA G4 TL {240V} Delta Electronics |
7,600 W | -4 W | 240.0 V | 500.0 V | 97.37% |
What Are the Interconnection Limits and Best-Fit Uses for Fortress Power LLC: Avalon HV PC76 {240V}?
Check Fortress Power LLC: Avalon HV PC76 {240V} (7,604 W AC, 40 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 450 V DC on Fortress Power LLC: Avalon HV PC76 {240V}.
Fortress Power LLC: Avalon HV PC76 {240V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 40 A OCPD breaker (31.7 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.41%) and MPPT window (175-450 V) directly against ABB: UNO-76-TL-OUTD-S-US-A {240V} (7,600 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Fortress Power LLC: Avalon HV PC76 {240V} by Fortress Power LLC covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Fortress Power LLC: Avalon HV PC76 {240V} require?
At 7,604 W continuous AC (240 V), continuous current is 31.7 A; 125% NEC 690.8/705.12 sizing requires a 40 A breaker and 8 AWG Cu (75 C) wire.
Does Fortress Power LLC: Avalon HV PC76 {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 40 A at 240 V means PASS (120% Rule).
How does Fortress Power LLC: Avalon HV PC76 {240V} compare to ABB: UNO-76-TL-OUTD-S-US-A {240V}?
Fortress Power LLC: Avalon HV PC76 {240V} delivers 7,604 W AC at 97.41% CEC efficiency with a 450 V DC ceiling, while ABB: UNO-76-TL-OUTD-S-US-A {240V} outputs 7,600 W at 240 V.