EPC Power Corp: HY LC12/6-7 {480V} — CEC Inverter Specifications

Manufacturer: EPC Power Corp Registry: CEC Verified Engineering Specification

EPC Power Corp: HY LC12/6-7 {480V} outputs 220,033 W AC at 480 V, 3-phase (264.7 A continuous, 400 A OCPD), ranking #2,164 of 2,343 CEC inverters at 95.51% efficiency with a 455-600 V MPPT window and 600 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
220,033 W
AC Voltage
480 V, 3-phase
Min PV Breaker
400 A (parallel Cu feeders)
CEC Efficiency
95.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does EPC Power Corp: HY LC12/6-7 {480V} Compare Against Peer CEC Listings?

Breaker sizing (400 A), parallel Cu feeders wire rules, and DC input limits for EPC Power Corp: HY LC12/6-7 {480V}.

Classified as a hybrid battery-capable inverter (active in CEC directory), EPC Power Corp: HY LC12/6-7 {480V} requires 330.9 A design capacity -> 400 A breaker using parallel Cu feeders copper at 75 C terminals. Weighted efficiency sits at 95.51% (-1.31 pts vs overall CEC median) across 2,343 CEC models, while commercial 480 v, 3-phase switchgear interconnection uses 1,200a bus / 1,200a main (480v) or nec 705.11 supply-side tap.

Where Does EPC Power Corp: HY LC12/6-7 {480V} Fall Across Listed CEC Models?

Output power comparison showing where EPC Power Corp: HY LC12/6-7 {480V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where EPC Power Corp: HY LC12/6-7 {480V} (220,033 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACEPC Power Corp: HY: 220,033 W

What Dataset Percentiles Define EPC Power Corp: HY LC12/6-7 {480V}?

Relative ranking of EPC Power Corp: HY LC12/6-7 {480V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

EPC Power Corp: HY LC12/6-7 {480V} Technical ThresholdsPercentile comparison for EPC Power Corp: HY LC12/6-7 {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output220,033 WCEC Efficiency95.51%Backfeed Breaker400 A

What Do the Dataset Ranks Show for EPC Power Corp: HY LC12/6-7 {480V}?

Snapshot of EPC Power Corp: HY LC12/6-7 {480V} efficiency rank (#2,164), OCPD breaker size, MPPT span, and busbar verdict.

Eff #2,164 / 2,343

95.51% CEC Weighted Efficiency

-2.51 pts vs the 98.02% 480 V median; overall power rank #242 (220,033 W, top 10.3%; higher than 89.7% of peers).

NEC 705.12 Check

400 A Required Backfeed OCPD

125% x 264.7 A = 330.9 A -> 400 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

455 V - 600 V (Max 600 V DC)

Tracking span of 145.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 220033.0W / 480 V 3-phase -> 264.7 A | Breaker >= 1.25 * 264.7 = 330.9 A -> 400 A

CEC Inverters.csv for EPC Power Corp: HY LC12/6-7 {480V}: Paco=220033.0 W, Vac=480 V, Vdcmax=600.0 V, Eff=95.51%.

Result: Min 400 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (480V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for EPC Power Corp: HY LC12/6-7 {480V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for EPC Power Corp: HY LC12/6-7 {480V}.

Official California Energy Commission (NREL SAM) test parameters for EPC Power Corp: HY LC12/6-7 {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 220,033 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 600 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 455 V - 600 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 485.023 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.51% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to EPC Power Corp: HY LC12/6-7 {480V} (480 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for EPC Power Corp: HY LC12/6-7 {480V} at 480 V, 3-phase.

Evaluates EPC Power Corp: HY LC12/6-7 {480V} (400 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 400 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 400 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (480V) 120 A 400 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (480V) 160 A 400 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (480V) 240 A 400 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With EPC Power Corp: HY LC12/6-7 {480V}?

Minimum and maximum series solar module strings fitting EPC Power Corp: HY LC12/6-7 {480V} MPPT and 600 V limits.

Sampled CEC PV modules aligned within 455.0-600.0 V MPPT and 600.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 14 panels (fixed) 6.16 kW
G-Star Pte Ltd GSN8K66T(H)740WT 740.0 W 54.38 V 11 panels (fixed) 8.14 kW

Which Competing Grid-Support Inverters Compare to EPC Power Corp: HY LC12/6-7 {480V}?

Peer 480 V, 3-phase CEC inverters near 220,033 W AC output such as Chint Power Systems America: SCH200K-T-US-480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Chint Power Systems America: SCH200K-T-US-480 {480V}
Chint Power Systems America
200,000 W -20033 W 480.0 V 1300.0 V 97.72%
DYNAPOWER COMPANY LLC: MPS-250 {480V}
DYNAPOWER COMPANY LLC
248,910 W +28877 W 480.0 V 600.0 V 95.24%
DYNAPOWER COMPANY LLC: MPS-250HV {480V}
DYNAPOWER COMPANY LLC
249,619 W +29586 W 480.0 V 830.0 V 96.2%
Chint Power Systems America: CPS ECB125KTL-M/US-480 {480V}
Chint Power Systems America
125,000 W -95033 W 480.0 V 1100.0 V 97.2%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for EPC Power Corp: HY LC12/6-7 {480V}?

Check EPC Power Corp: HY LC12/6-7 {480V} (220,033 W AC, 400 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 600 V DC on EPC Power Corp: HY LC12/6-7 {480V}.

EPC Power Corp: HY LC12/6-7 {480V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 400 A OCPD breaker (264.7 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.51%) and MPPT window (455-600 V) directly against Chint Power Systems America: SCH200K-T-US-480 {480V} (200,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for EPC Power Corp: HY LC12/6-7 {480V} by EPC Power Corp covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does EPC Power Corp: HY LC12/6-7 {480V} require?

At 220,033 W continuous AC (480 V, 3-phase), continuous current is 264.7 A; 125% NEC 690.8/705.12 sizing requires a 400 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does EPC Power Corp: HY LC12/6-7 {480V} require?

At 220,033 W AC and 480 V, 3-phase, continuous line current is 264.7 A, requiring a 400 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does EPC Power Corp: HY LC12/6-7 {480V} compare to Chint Power Systems America: SCH200K-T-US-480 {480V}?

EPC Power Corp: HY LC12/6-7 {480V} delivers 220,033 W AC at 95.51% CEC efficiency with a 600 V DC ceiling, while Chint Power Systems America: SCH200K-T-US-480 {480V} outputs 200,000 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.