Enphase Energy Inc: IQ8HC-72-2-US {208V} outputs 359 W AC at 208 V, commercial single-phase (1.7 A continuous, 15 A OCPD), ranking #2,097 of 2,343 CEC inverters at 95.75% efficiency with a 29.5-45 V MPPT window and 45 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 359 W
- AC Voltage
- 208 V, commercial single-phase
- Min PV Breaker
- 15 A (14 AWG Cu)
- CEC Efficiency
- 95.75%
How Does Enphase Energy Inc: IQ8HC-72-2-US {208V} Compare Against Peer CEC Listings?
CEC efficiency rank (#2,097), 29.5-45 V MPPT tracking, and panel fit for Enphase Energy Inc: IQ8HC-72-2-US {208V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
Operating at 208 V, commercial single-phase, Enphase Energy Inc: IQ8HC-72-2-US {208V} converts DC array energy at 95.75% CEC weighted efficiency (below overall CEC median; higher than 10.5% of peers) with a 45 V max DC input and 10.1333 A max input current for NEC 690.7 string safety. Compare this 359 W grid-tied PV inverter directly with Aptos Solar Technology LLC: MAC-400 {208V} (387 W). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
Where Does Enphase Energy Inc: IQ8HC-72-2-US {208V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Enphase Energy Inc: IQ8HC-72-2-US {208V} at 359 W continuous AC output. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Dataset Percentiles Define Enphase Energy Inc: IQ8HC-72-2-US {208V}?
Dataset percentiles comparing Enphase Energy Inc: IQ8HC-72-2-US {208V} against 2,343 certified grid-support inverters nationwide. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Do the Dataset Ranks Show for Enphase Energy Inc: IQ8HC-72-2-US {208V}?
Engineering highlights for Enphase Energy Inc: IQ8HC-72-2-US {208V} covering efficiency, 14 AWG Cu feeder, and panel compatibility. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
95.75% CEC Weighted Efficiency
-0.66 pts vs the 96.41% 208 V median; overall power rank #2,042 (359 W, below CEC median; higher than 12.7% of peers).
15 A Required Backfeed OCPD
125% x 1.7 A = 2.1 A -> 15 A standard OCPD using 14 AWG Cu (75 C).
29.5 V - 45 V (Max 45 V DC)
Tracking span of 15.5 V; listed since 2025-06-23 (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 359.0W / 208 V -> 1.7 A | Breaker >= 1.25 * 1.7 = 2.1 A -> 15 A
CEC Inverters.csv for Enphase Energy Inc: IQ8HC-72-2-US {208V}: Paco=359.0 W, Vac=208 V, Vdcmax=45.0 V, Eff=95.75%.
Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Enphase Energy Inc: IQ8HC-72-2-US {208V}?
California Energy Commission Solar Equipment List parameters for Enphase Energy Inc: IQ8HC-72-2-US {208V} (grid-tied PV inverter) interconnection. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 359 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 45 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 29.5 V - 45 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 10.1333 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 95.75% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2025-06-23 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Enphase Energy Inc: IQ8HC-72-2-US {208V} (208 V, commercial single-phase)?
Panelboard and switchgear backfeed allowances for Enphase Energy Inc: IQ8HC-72-2-US {208V} (15 A OCPD). Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 15 A | PASS (120% Commercial Busbar) |
| 400A Bus / 400A Main (208V) | 80 A | 15 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 15 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 15 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 15 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Enphase Energy Inc: IQ8HC-72-2-US {208V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for Enphase Energy Inc: IQ8HC-72-2-US {208V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW | 270.0 W | 42.56 V | 1 panel (micro/module) | 0.27 kW |
Which Competing Grid-Support Inverters Compare to Enphase Energy Inc: IQ8HC-72-2-US {208V}?
Four alternative CEC inverters matched to Enphase Energy Inc: IQ8HC-72-2-US {208V} (359 W AC), led by Aptos Solar Technology LLC: MAC-400 {208V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC: MAC-400 {208V} Aptos Solar Technology LLC |
387 W | +28 W | 208.0 V | 48.0 V | 96.11% |
| Aptos Solar Technology LLC: MAC-400R {208V} Aptos Solar Technology LLC |
387 W | +28 W | 208.0 V | 48.0 V | 96.11% |
| Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {208V} Chilicon Power LLC |
277 W | -82 W | 208.0 V | 32.0 V | 95.08% |
| Cherry Solution Co Ltd: CMI-600S-SA {208V} Cherry Solution Co Ltd |
608 W | +249 W | 208.0 V | 50.0 V | 96.49% |
What Are the Interconnection Limits and Best-Fit Uses for Enphase Energy Inc: IQ8HC-72-2-US {208V}?
Check Enphase Energy Inc: IQ8HC-72-2-US {208V} (359 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 45 V DC on Enphase Energy Inc: IQ8HC-72-2-US {208V}.
Enphase Energy Inc: IQ8HC-72-2-US {208V} Panel & Wire Spec
Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.7 A continuous).
Alternative Inverter Comparison
Compare efficiency (95.75%) and MPPT window (29.5-45 V) directly against Aptos Solar Technology LLC: MAC-400 {208V} (387 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Enphase Energy Inc: IQ8HC-72-2-US {208V} by Enphase Energy Inc covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.
What breaker and wire size does Enphase Energy Inc: IQ8HC-72-2-US {208V} require?
At 359 W continuous AC (208 V, commercial single-phase), continuous current is 1.7 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Enphase Energy Inc: IQ8HC-72-2-US {208V} require?
At 359 W AC and 208 V, commercial single-phase, continuous line current is 1.7 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does Enphase Energy Inc: IQ8HC-72-2-US {208V} compare to Aptos Solar Technology LLC: MAC-400 {208V}?
Enphase Energy Inc: IQ8HC-72-2-US {208V} delivers 359 W AC at 95.75% CEC efficiency with a 45 V DC ceiling, while Aptos Solar Technology LLC: MAC-400 {208V} outputs 387 W at 208 V, commercial single-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)