Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Aptos Solar Technology LLC: MAC-400R {208V} — CEC Inverter Specifications

Manufacturer: Aptos Solar Technology LLC Registry: CEC Verified Engineering Specification

Aptos Solar Technology LLC: MAC-400R {208V} outputs 387 W AC at 208 V, commercial single-phase (1.9 A continuous, 15 A OCPD), ranking #1,892 of 2,343 CEC inverters at 96.11% efficiency with a 38-48 V MPPT window and 48 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
387 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
96.11%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Aptos Solar Technology LLC: MAC-400R {208V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 208 V, commercial single-phase grid-support overview for Aptos Solar Technology LLC: MAC-400R {208V}.

Rated at 387 W AC (1.9 A continuous), Aptos Solar Technology LLC: MAC-400R {208V} ranks #1,892 of 2,343 CEC units at 96.11% efficiency (-0.30 pts vs the 96.41% 208 V median). Minimum 75 C copper conductor sizing for its 15 A circuit is 14 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 48 V DC at record local winter lows.

Where Does Aptos Solar Technology LLC: MAC-400R {208V} Fall Across Listed CEC Models?

Marks Aptos Solar Technology LLC: MAC-400R {208V} (387 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Aptos Solar Technology LLC: MAC-400R {208V} (387 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACAptos Solar Techno: 387 W

What Dataset Percentiles Define Aptos Solar Technology LLC: MAC-400R {208V}?

Benchmarks Aptos Solar Technology LLC: MAC-400R {208V} continuous AC output, 96.11% CEC weighted efficiency, and 15 A OCPD breaker demand.

Aptos Solar Technology LLC: MAC-400R {208V} Technical ThresholdsPercentile comparison for Aptos Solar Technology LLC: MAC-400R {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output387 WCEC Efficiency96.11%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Aptos Solar Technology LLC: MAC-400R {208V}?

Four key NEC 705.12 and California Energy Commission metrics defining Aptos Solar Technology LLC: MAC-400R {208V} by Aptos Solar Technology LLC.

Eff #1,892 / 2,343

96.11% CEC Weighted Efficiency

-0.30 pts vs the 96.41% 208 V median; overall power rank #1,990 (387 W, below CEC median; higher than 14.9% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 1.9 A = 2.4 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

38 V - 48 V (Max 48 V DC)

Tracking span of 10.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 387.3W / 208 V -> 1.9 A | Breaker >= 1.25 * 1.9 = 2.4 A -> 15 A

CEC Inverters.csv for Aptos Solar Technology LLC: MAC-400R {208V}: Paco=387.3 W, Vac=208 V, Vdcmax=48.0 V, Eff=96.11%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Aptos Solar Technology LLC: MAC-400R {208V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Aptos Solar Technology LLC: MAC-400R {208V}.

Official California Energy Commission (NREL SAM) test parameters for Aptos Solar Technology LLC: MAC-400R {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 387 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 48 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 38 V - 48 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 9.59365 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.11% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Aptos Solar Technology LLC: MAC-400R {208V} (208 V, commercial single-phase)?

Evaluates Aptos Solar Technology LLC: MAC-400R {208V} (15 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Aptos Solar Technology LLC: MAC-400R {208V} (15 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 15 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 15 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 15 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 15 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 15 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Aptos Solar Technology LLC: MAC-400R {208V}?

Sample PV string lengths aligned within 38-48 V MPPT and 48 V DC max at -10 C. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sampled CEC PV modules aligned within 38.0-48.0 V MPPT and 48.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW 270.0 W 42.56 V 1 panel (micro/module) 0.27 kW

Which Competing Grid-Support Inverters Compare to Aptos Solar Technology LLC: MAC-400R {208V}?

Competing CEC grid-support inverters near 387 W AC and 208 V, commercial single-phase, led by Enphase Energy Inc: IQ8H-3P-72-E-US {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Enphase Energy Inc: IQ8H-3P-72-E-US {208V}
Enphase Energy Inc
380 W -7 W 208.0 V 45.0 V 97.11%
Enphase Energy Inc: IQ8H-3P-72-M-US {208V}
Enphase Energy Inc
380 W -7 W 208.0 V 45.0 V 97.11%
Enphase Energy Inc: IQ9N-A-DOM-US {208V}
Enphase Energy Inc
405 W +18 W 208.0 V 45.0 V 96.6%
Enphase Energy Inc: IQ9N-A-US {208V}
Enphase Energy Inc
405 W +18 W 208.0 V 45.0 V 96.6%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Aptos Solar Technology LLC: MAC-400R {208V}?

Check Aptos Solar Technology LLC: MAC-400R {208V} (387 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 48 V DC on Aptos Solar Technology LLC: MAC-400R {208V}.

Aptos Solar Technology LLC: MAC-400R {208V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.9 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.11%) and MPPT window (38-48 V) directly against Enphase Energy Inc: IQ8H-3P-72-E-US {208V} (380 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Aptos Solar Technology LLC: MAC-400R {208V} by Aptos Solar Technology LLC covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Aptos Solar Technology LLC: MAC-400R {208V} require?

At 387 W continuous AC (208 V, commercial single-phase), continuous current is 1.9 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Aptos Solar Technology LLC: MAC-400R {208V} require?

At 387 W AC and 208 V, commercial single-phase, continuous line current is 1.9 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Aptos Solar Technology LLC: MAC-400R {208V} compare to Enphase Energy Inc: IQ8H-3P-72-E-US {208V}?

Aptos Solar Technology LLC: MAC-400R {208V} delivers 387 W AC at 96.11% CEC efficiency with a 48 V DC ceiling, while Enphase Energy Inc: IQ8H-3P-72-E-US {208V} outputs 380 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.