Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Destin Power Inc: SAVEEN1000-ES02HUS {440V} — CEC Inverter Specifications

Manufacturer: Destin Power Inc Registry: CEC Verified Engineering Specification

Destin Power Inc: SAVEEN1000-ES02HUS {440V} outputs 1,000,000 W AC at 440 V, 3-phase (1312.2 A continuous, 1,650 A OCPD), ranking #199 of 2,343 CEC inverters at 98.28% efficiency with a 740-900 V MPPT window and 900 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
1,000,000 W
AC Voltage
440 V, 3-phase
Min PV Breaker
1,650 A (parallel Cu feeders)
CEC Efficiency
98.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Destin Power Inc: SAVEEN1000-ES02HUS {440V} Compare Against Peer CEC Listings?

Breaker sizing (1,650 A), parallel Cu feeders wire rules, and DC input limits for Destin Power Inc: SAVEEN1000-ES02HUS {440V}.

For NEC 705.12 solar interconnection, Destin Power Inc: SAVEEN1000-ES02HUS {440V} outputs 1312.2 A continuous AC at 440 V, 3-phase and needs a 1,650 A backfeed breaker on parallel Cu feeders (75 C). Commercial 440 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (440V) or NEC 705.11 supply-side tap. Conversion efficiency scores 98.28% (#199 of 2,343, +1.46 pts vs overall CEC median).

Where Does Destin Power Inc: SAVEEN1000-ES02HUS {440V} Fall Across Listed CEC Models?

Output power comparison showing where Destin Power Inc: SAVEEN1000-ES02HUS {440V} sits among all 2,343 CEC-listed grid-support inverters. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Destin Power Inc: SAVEEN1000-ES02HUS {440V} (1,000,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACDestin Power Inc: : 1,000,000 W

What Dataset Percentiles Define Destin Power Inc: SAVEEN1000-ES02HUS {440V}?

Relative ranking of Destin Power Inc: SAVEEN1000-ES02HUS {440V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Destin Power Inc: SAVEEN1000-ES02HUS {440V} Technical ThresholdsPercentile comparison for Destin Power Inc: SAVEEN1000-ES02HUS {440V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output1,000,000 WCEC Efficiency98.28%Backfeed Breaker1,650 A

What Do the Dataset Ranks Show for Destin Power Inc: SAVEEN1000-ES02HUS {440V}?

Snapshot of Destin Power Inc: SAVEEN1000-ES02HUS {440V} efficiency rank (#199), OCPD breaker size, MPPT span, and busbar verdict.

Eff #199 / 2,343

98.28% CEC Weighted Efficiency

+0.81 pts vs the 97.47% 440 V median; overall power rank #167 (1,000,000 W, top 7.2%; higher than 92.8% of peers).

NEC 705.12 Check

1,650 A Required Backfeed OCPD

125% x 1312.2 A = 1640.2 A -> 1,650 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

740 V - 900 V (Max 900 V DC)

Tracking span of 160.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 440 V, 3-phase switchgear (200A Bus / 200A Main (440V) to 1,200A Bus / 1,200A Main (440V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1000000.0W / 440 V 3-phase -> 1312.2 A | Breaker >= 1.25 * 1312.2 = 1640.2 A -> 1,650 A

CEC Inverters.csv for Destin Power Inc: SAVEEN1000-ES02HUS {440V}: Paco=1000000.0 W, Vac=440 V, Vdcmax=900.0 V, Eff=98.28%.

Result: Min 1,650 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (440V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for Destin Power Inc: SAVEEN1000-ES02HUS {440V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Destin Power Inc: SAVEEN1000-ES02HUS {440V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Destin Power Inc: SAVEEN1000-ES02HUS {440V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 1,000,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 440 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 900 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 740 V - 900 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1225.96 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.28% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Destin Power Inc: SAVEEN1000-ES02HUS {440V} (440 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Destin Power Inc: SAVEEN1000-ES02HUS {440V} at 440 V, 3-phase.

Evaluates Destin Power Inc: SAVEEN1000-ES02HUS {440V} (1650 A required OCPD at 440 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (440V) 40 A 1,650 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (440V) 80 A 1,650 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (440V) 120 A 1,650 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (440V) 160 A 1,650 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (440V) 240 A 1,650 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which Competing Grid-Support Inverters Compare to Destin Power Inc: SAVEEN1000-ES02HUS {440V}?

Peer 440 V, 3-phase CEC inverters near 1,000,000 W AC output such as EPC Power Corp: 50-200100 {720V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
EPC Power Corp: 50-200100 {720V}
EPC Power Corp
561,806 W -438194 W 720.0 V 1500.0 V 98.58%
Schneider Electric USA Inc: CS1666-3-NA {575V}
Schneider Electric USA Inc
1,666,000 W +666000 W 575.0 V 1200.0 V 97.54%
SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}
SINENG ELECTRIC CO LTD
1,726,700 W +726700 W 690.0 V 1500.0 V 98.32%
ABB: PVS-175-TL-POWER-MODULE-1-US {800V}
ABB
179,574 W -820426 W 800.0 V 1200.0 V 97.39%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Destin Power Inc: SAVEEN1000-ES02HUS {440V}?

Check Destin Power Inc: SAVEEN1000-ES02HUS {440V} (1,000,000 W AC, 1,650 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 440 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (440V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 900 V DC on Destin Power Inc: SAVEEN1000-ES02HUS {440V}.

Destin Power Inc: SAVEEN1000-ES02HUS {440V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,650 A OCPD breaker (1312.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.28%) and MPPT window (740-900 V) directly against EPC Power Corp: 50-200100 {720V} (561,806 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Destin Power Inc: SAVEEN1000-ES02HUS {440V} by Destin Power Inc covering breaker sizing, MPPT limits, and 440 V, 3-phase interconnection.

What breaker and wire size does Destin Power Inc: SAVEEN1000-ES02HUS {440V} require?

At 1,000,000 W continuous AC (440 V, 3-phase), continuous current is 1312.2 A; 125% NEC 690.8/705.12 sizing requires a 1,650 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does Destin Power Inc: SAVEEN1000-ES02HUS {440V} require?

At 1,000,000 W AC and 440 V, 3-phase, continuous line current is 1312.2 A, requiring a 1,650 A OCPD and 1,200A Bus / 1,200A Main (440V) or NEC 705.11 interconnection.

How does Destin Power Inc: SAVEEN1000-ES02HUS {440V} compare to EPC Power Corp: 50-200100 {720V}?

Destin Power Inc: SAVEEN1000-ES02HUS {440V} delivers 1,000,000 W AC at 98.28% CEC efficiency with a 900 V DC ceiling, while EPC Power Corp: 50-200100 {720V} outputs 561,806 W at 440 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.