Delta Electronics: SOLIVIA 52 NA G4 TL {208V} — CEC Inverter Specifications

Manufacturer: Delta Electronics Registry: CEC Verified Engineering Specification

Delta Electronics: SOLIVIA 52 NA G4 TL {208V} outputs 5,200 W AC at 208 V, commercial single-phase (25.0 A continuous, 35 A OCPD), ranking #564 of 2,343 CEC inverters at 97.45% efficiency with a 100-500 V MPPT window and 500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
5,200 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
35 A (8 AWG Cu)
CEC Efficiency
97.45%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Delta Electronics: SOLIVIA 52 NA G4 TL {208V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 208 V, commercial single-phase grid-support overview for Delta Electronics: SOLIVIA 52 NA G4 TL {208V}.

Ranking #1,466 of 2,343 CEC inverters (below CEC median; higher than 37.4% of peers), Delta Electronics: SOLIVIA 52 NA G4 TL {208V} is a grid-tied PV inverter delivering 5,200 W continuous AC at 208 V, commercial single-phase (25.0 A continuous). Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 97.45% (+1.04 pts vs the 96.41% 208 V median) against peers like ABB: PVI-5000-OUTD-US-A {208V} (5,000 W).

Where Does Delta Electronics: SOLIVIA 52 NA G4 TL {208V} Fall Across Listed CEC Models?

Marks Delta Electronics: SOLIVIA 52 NA G4 TL {208V} (5,200 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Delta Electronics: SOLIVIA 52 NA G4 TL {208V} (5,200 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACDelta Electronics:: 5,200 W

What Dataset Percentiles Define Delta Electronics: SOLIVIA 52 NA G4 TL {208V}?

Benchmarks Delta Electronics: SOLIVIA 52 NA G4 TL {208V} continuous AC output, 97.45% CEC weighted efficiency, and 35 A OCPD breaker demand.

Delta Electronics: SOLIVIA 52 NA G4 TL {208V} Technical ThresholdsPercentile comparison for Delta Electronics: SOLIVIA 52 NA G4 TL {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output5,200 WCEC Efficiency97.45%Backfeed Breaker35 A

What Do the Dataset Ranks Show for Delta Electronics: SOLIVIA 52 NA G4 TL {208V}?

Four key NEC 705.12 and California Energy Commission metrics defining Delta Electronics: SOLIVIA 52 NA G4 TL {208V} by Delta Electronics.

Eff #564 / 2,343

97.45% CEC Weighted Efficiency

+1.04 pts vs the 96.41% 208 V median; overall power rank #1,466 (5,200 W, below CEC median; higher than 37.4% of peers).

NEC 705.12 Check

35 A Required Backfeed OCPD

125% x 25.0 A = 31.2 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

100 V - 500 V (Max 500 V DC)

Tracking span of 400.0 V; listed since 2020-11-12 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 5200.0W / 208 V -> 25.0 A | Breaker >= 1.25 * 25.0 = 31.2 A -> 35 A

CEC Inverters.csv for Delta Electronics: SOLIVIA 52 NA G4 TL {208V}: Paco=5200.0 W, Vac=208 V, Vdcmax=500.0 V, Eff=97.45%.

Result: Min 35 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Delta Electronics: SOLIVIA 52 NA G4 TL {208V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Delta Electronics: SOLIVIA 52 NA G4 TL {208V}.

Official California Energy Commission (NREL SAM) test parameters for Delta Electronics: SOLIVIA 52 NA G4 TL {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 5,200 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 100 V - 500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 14.0416 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.45% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2020-11-12 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Delta Electronics: SOLIVIA 52 NA G4 TL {208V} (208 V, commercial single-phase)?

Evaluates Delta Electronics: SOLIVIA 52 NA G4 TL {208V} (35 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Delta Electronics: SOLIVIA 52 NA G4 TL {208V} (35 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 35 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 35 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 35 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 35 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 35 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Delta Electronics: SOLIVIA 52 NA G4 TL {208V}?

Sample PV string lengths aligned within 100-500 V MPPT and 500 V DC max at -10 C. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sampled CEC PV modules aligned within 100.0-500.0 V MPPT and 500.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 3 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 3 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 3 to 11 panels 4.67 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 4 to 12 panels 2.4 kW

Which Competing Grid-Support Inverters Compare to Delta Electronics: SOLIVIA 52 NA G4 TL {208V}?

Competing CEC grid-support inverters near 5,200 W AC and 208 V, commercial single-phase, led by ABB: PVI-5000-OUTD-US-A {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: PVI-5000-OUTD-US-A {208V}
ABB
5,000 W -200 W 208.0 V 480.0 V 96.0%
ABB: PVI-5000-OUTD-US-Z-A {208V}
ABB
5,000 W -200 W 208.0 V 480.0 V 96.0%
ABB: PVI-5000-OUTD-US-Z-M-A {208V}
ABB
5,000 W -200 W 208.0 V 480.0 V 96.0%
ABB: UNO-DM-50-TL-PLUS-US-SB-RA {208V}
ABB
4,600 W -600 W 208.0 V 480.0 V 96.31%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Delta Electronics: SOLIVIA 52 NA G4 TL {208V}?

Check Delta Electronics: SOLIVIA 52 NA G4 TL {208V} (5,200 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 500 V DC on Delta Electronics: SOLIVIA 52 NA G4 TL {208V}.

Delta Electronics: SOLIVIA 52 NA G4 TL {208V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (25.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.45%) and MPPT window (100-500 V) directly against ABB: PVI-5000-OUTD-US-A {208V} (5,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Delta Electronics: SOLIVIA 52 NA G4 TL {208V} by Delta Electronics covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Delta Electronics: SOLIVIA 52 NA G4 TL {208V} require?

At 5,200 W continuous AC (208 V, commercial single-phase), continuous current is 25.0 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Delta Electronics: SOLIVIA 52 NA G4 TL {208V} require?

At 5,200 W AC and 208 V, commercial single-phase, continuous line current is 25.0 A, requiring a 35 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Delta Electronics: SOLIVIA 52 NA G4 TL {208V} compare to ABB: PVI-5000-OUTD-US-A {208V}?

Delta Electronics: SOLIVIA 52 NA G4 TL {208V} delivers 5,200 W AC at 97.45% CEC efficiency with a 500 V DC ceiling, while ABB: PVI-5000-OUTD-US-A {208V} outputs 5,000 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.