Darfon Electronics Corp: H7xxxxxx {240V} outputs 9,604 W AC at 240 V (40.0 A continuous, 50 A OCPD), ranking #1,508 of 2,343 CEC inverters at 96.53% efficiency with a 230-410 V MPPT window and 410 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 9,604 W
- AC Voltage
- 240 V
- Min PV Breaker
- 50 A (8 AWG Cu)
- CEC Efficiency
- 96.53%
How Does Darfon Electronics Corp: H7xxxxxx {240V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Darfon Electronics Corp: H7xxxxxx {240V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
Ranking #978 of 2,343 CEC inverters (top 41.7%; higher than 58.3% of peers), Darfon Electronics Corp: H7xxxxxx {240V} is a hybrid battery-capable inverter delivering 9,604 W continuous AC at 240 V (40.0 A continuous). Its 50 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Weighted CEC efficiency reaches 96.53% (-0.15 pts vs the 96.68% 240 V median) against peers like Altenergy Power System Inc: ELS-96 {240V} (9,606 W).
Where Does Darfon Electronics Corp: H7xxxxxx {240V} Fall Across Listed CEC Models?
Marks Darfon Electronics Corp: H7xxxxxx {240V} (9,604 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define Darfon Electronics Corp: H7xxxxxx {240V}?
Benchmarks Darfon Electronics Corp: H7xxxxxx {240V} continuous AC output, 96.53% CEC weighted efficiency, and 50 A OCPD breaker demand.
What Do the Dataset Ranks Show for Darfon Electronics Corp: H7xxxxxx {240V}?
Four key NEC 705.12 and California Energy Commission metrics defining Darfon Electronics Corp: H7xxxxxx {240V} by Darfon Electronics Corp.
96.53% CEC Weighted Efficiency
-0.15 pts vs the 96.68% 240 V median; overall power rank #978 (9,604 W, top 41.7%; higher than 58.3% of peers).
50 A Required Backfeed OCPD
125% x 40.0 A = 50.0 A -> 50 A standard OCPD using 8 AWG Cu (75 C).
230 V - 410 V (Max 410 V DC)
Tracking span of 180.0 V; active in CEC directory (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 9604.0W / 240 V -> 40.0 A | Breaker >= 1.25 * 40.0 = 50.0 A -> 50 A
CEC Inverters.csv for Darfon Electronics Corp: H7xxxxxx {240V}: Paco=9604.0 W, Vac=240 V, Vdcmax=410.0 V, Eff=96.53%.
Result: Min 50 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for Darfon Electronics Corp: H7xxxxxx {240V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Darfon Electronics Corp: H7xxxxxx {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 9,604 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 410 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 230 V - 410 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 27.6368 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.53% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for Darfon Electronics Corp: H7xxxxxx {240V}?
Evaluates Darfon Electronics Corp: H7xxxxxx {240V} (50 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 50 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 50 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 50 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 50 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 50 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Darfon Electronics Corp: H7xxxxxx {240V}?
Sample PV string lengths aligned within 230-410 V MPPT and 410 V DC max at -10 C. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 6 to 7 panels | 4.13 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 7 to 9 panels | 3.96 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 7 to 9 panels | 3.83 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 8 to 10 panels | 2.0 kW |
Which Competing Grid-Support Inverters Compare to Darfon Electronics Corp: H7xxxxxx {240V}?
Competing CEC grid-support inverters near 9,604 W AC and 240 V, led by Altenergy Power System Inc: ELS-96 {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Altenergy Power System Inc: ELS-96 {240V} Altenergy Power System Inc |
9,606 W | +2 W | 240.0 V | 60.0 V | 93.76% |
| Afore New Energy Technology (Shanghai) Co Ltd: AF96K-DH {240V} Afore New Energy Technology (Shanghai) Co Ltd |
9,592 W | -12 W | 240.0 V | 480.0 V | 97.87% |
| AIMS Power Inc: PIHY9600 {240V} AIMS Power Inc |
9,592 W | -12 W | 240.0 V | 480.0 V | 97.87% |
| Alpha ESS Co Ltd: SMILE-SPB96-INV {240V} Alpha ESS Co Ltd |
9,616 W | +12 W | 240.0 V | 450.0 V | 96.15% |
What Are the Interconnection Limits and Best-Fit Uses for Darfon Electronics Corp: H7xxxxxx {240V}?
Check Darfon Electronics Corp: H7xxxxxx {240V} (9,604 W AC, 50 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 50 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 410 V DC on Darfon Electronics Corp: H7xxxxxx {240V}.
Darfon Electronics Corp: H7xxxxxx {240V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 50 A OCPD breaker (40.0 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.53%) and MPPT window (230-410 V) directly against Altenergy Power System Inc: ELS-96 {240V} (9,606 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Darfon Electronics Corp: H7xxxxxx {240V} by Darfon Electronics Corp covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Darfon Electronics Corp: H7xxxxxx {240V} require?
At 9,604 W continuous AC (240 V), continuous current is 40.0 A; 125% NEC 690.8/705.12 sizing requires a 50 A breaker and 8 AWG Cu (75 C) wire.
Does Darfon Electronics Corp: H7xxxxxx {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 50 A at 240 V means Needs Derate / Tap 705.11.
How does Darfon Electronics Corp: H7xxxxxx {240V} compare to Altenergy Power System Inc: ELS-96 {240V}?
Darfon Electronics Corp: H7xxxxxx {240V} delivers 9,604 W AC at 96.53% CEC efficiency with a 410 V DC ceiling, while Altenergy Power System Inc: ELS-96 {240V} outputs 9,606 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)