AIMS Power Inc: PIHY9600 {240V} — CEC Inverter Specifications

Manufacturer: AIMS Power Inc Registry: CEC Verified Engineering Specification

AIMS Power Inc: PIHY9600 {240V} outputs 9,592 W AC at 240 V (40.0 A continuous, 50 A OCPD), ranking #394 of 2,343 CEC inverters at 97.87% efficiency with a 235-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
9,592 W
AC Voltage
240 V
Min PV Breaker
50 A (8 AWG Cu)
CEC Efficiency
97.87%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AIMS Power Inc: PIHY9600 {240V} Compare Against Peer CEC Listings?

Breaker sizing (50 A), 8 AWG Cu wire rules, and DC input limits for AIMS Power Inc: PIHY9600 {240V}.

For NEC 705.12 solar interconnection, AIMS Power Inc: PIHY9600 {240V} outputs 40.0 A continuous AC at 240 V and needs a 50 A backfeed breaker on 8 AWG Cu (75 C). Its 50 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Conversion efficiency scores 97.87% (#394 of 2,343, +1.05 pts vs overall CEC median).

Where Does AIMS Power Inc: PIHY9600 {240V} Fall Across Listed CEC Models?

Output power comparison showing where AIMS Power Inc: PIHY9600 {240V} sits among all 2,343 CEC-listed grid-support inverters. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where AIMS Power Inc: PIHY9600 {240V} (9,592 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACAIMS Power Inc: PI: 9,592 W

What Dataset Percentiles Define AIMS Power Inc: PIHY9600 {240V}?

Relative ranking of AIMS Power Inc: PIHY9600 {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

AIMS Power Inc: PIHY9600 {240V} Technical ThresholdsPercentile comparison for AIMS Power Inc: PIHY9600 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output9,592 WCEC Efficiency97.87%Backfeed Breaker50 A

What Do the Dataset Ranks Show for AIMS Power Inc: PIHY9600 {240V}?

Snapshot of AIMS Power Inc: PIHY9600 {240V} efficiency rank (#394), OCPD breaker size, MPPT span, and busbar verdict.

Eff #394 / 2,343

97.87% CEC Weighted Efficiency

+1.19 pts vs the 96.68% 240 V median; overall power rank #983 (9,592 W, top 42.0%; higher than 58.0% of peers).

NEC 705.12 Check

50 A Required Backfeed OCPD

125% x 40.0 A = 50.0 A -> 50 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

235 V - 480 V (Max 480 V DC)

Tracking span of 245.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 9592.0W / 240 V -> 40.0 A | Breaker >= 1.25 * 40.0 = 50.0 A -> 50 A

CEC Inverters.csv for AIMS Power Inc: PIHY9600 {240V}: Paco=9592.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.87%.

Result: Min 50 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for AIMS Power Inc: PIHY9600 {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for AIMS Power Inc: PIHY9600 {240V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for AIMS Power Inc: PIHY9600 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 9,592 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 235 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 27.2255 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.87% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for AIMS Power Inc: PIHY9600 {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for AIMS Power Inc: PIHY9600 {240V} at 240 V. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Evaluates AIMS Power Inc: PIHY9600 {240V} (50 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 50 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 50 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 50 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 50 A PASS (120% Rule)
225A Bus / 200A Main 70 A 50 A PASS (120% Rule)

Which CEC PV Module Strings Pair With AIMS Power Inc: PIHY9600 {240V}?

Minimum and maximum series solar module strings fitting AIMS Power Inc: PIHY9600 {240V} MPPT and 480 V limits.

Sampled CEC PV modules aligned within 235.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 6 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 8 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 7 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 9 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to AIMS Power Inc: PIHY9600 {240V}?

Peer 240 V CEC inverters near 9,592 W AC output such as Afore New Energy Technology (Shanghai) Co Ltd: AF96K-DH {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Afore New Energy Technology (Shanghai) Co Ltd: AF96K-DH {240V}
Afore New Energy Technology (Shanghai) Co Ltd
9,592 W Tie (0 W) 240.0 V 480.0 V 97.87%
CESC New Energy Technology Co Ltd: Mars 9600 HVSP {240V}
CESC New Energy Technology Co Ltd
9,592 W Tie (0 W) 240.0 V 480.0 V 97.87%
Darfon Electronics Corp: H7xxxxxx {240V}
Darfon Electronics Corp
9,604 W +12 W 240.0 V 410.0 V 96.53%
Altenergy Power System Inc: ELS-96 {240V}
Altenergy Power System Inc
9,606 W +14 W 240.0 V 60.0 V 93.76%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for AIMS Power Inc: PIHY9600 {240V}?

Check AIMS Power Inc: PIHY9600 {240V} (9,592 W AC, 50 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 50 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on AIMS Power Inc: PIHY9600 {240V}.

AIMS Power Inc: PIHY9600 {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 50 A OCPD breaker (40.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.87%) and MPPT window (235-480 V) directly against Afore New Energy Technology (Shanghai) Co Ltd: AF96K-DH {240V} (9,592 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for AIMS Power Inc: PIHY9600 {240V} by AIMS Power Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does AIMS Power Inc: PIHY9600 {240V} require?

At 9,592 W continuous AC (240 V), continuous current is 40.0 A; 125% NEC 690.8/705.12 sizing requires a 50 A breaker and 8 AWG Cu (75 C) wire.

Does AIMS Power Inc: PIHY9600 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 50 A at 240 V means Needs Derate / Tap 705.11.

How does AIMS Power Inc: PIHY9600 {240V} compare to Afore New Energy Technology (Shanghai) Co Ltd: AF96K-DH {240V}?

AIMS Power Inc: PIHY9600 {240V} delivers 9,592 W AC at 97.87% CEC efficiency with a 480 V DC ceiling, while Afore New Energy Technology (Shanghai) Co Ltd: AF96K-DH {240V} outputs 9,592 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.