Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} — CEC Inverter Specifications

Manufacturer: CSI Solar Co Ltd Registry: CEC Verified Engineering Specification

CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} outputs 125,083 W AC at 600 V, 3-phase (120.4 A continuous, 175 A OCPD), ranking #148 of 2,343 CEC inverters at 98.35% efficiency with a 860-1,250 V MPPT window and 1,250 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
125,083 W
AC Voltage
600 V, 3-phase
Min PV Breaker
175 A (2/0 AWG Cu)
CEC Efficiency
98.35%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 600 V, 3-phase grid-support overview for CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V}.

Ranking #295 of 2,343 CEC inverters (top 12.6%; higher than 87.4% of peers), CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} is a grid-tied PV inverter delivering 125,083 W continuous AC at 600 V, 3-phase (120.4 A continuous). Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 98.35% (+0.07 pts vs the 98.28% 600 V median) against peers like Ginlong Technologies Co Ltd: Solis-125K1-EHV-5G {600V} (125,083 W).

Where Does CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} Fall Across Listed CEC Models?

Marks CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} (125,083 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} (125,083 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACCSI Solar Co Ltd: : 125,083 W

What Dataset Percentiles Define CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V}?

Benchmarks CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} continuous AC output, 98.35% CEC weighted efficiency, and 175 A OCPD breaker demand.

CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} Technical ThresholdsPercentile comparison for CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output125,083 WCEC Efficiency98.35%Backfeed Breaker175 A

What Do the Dataset Ranks Show for CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V}?

Four key NEC 705.12 and California Energy Commission metrics defining CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} by CSI Solar Co Ltd.

Eff #148 / 2,343

98.35% CEC Weighted Efficiency

+0.07 pts vs the 98.28% 600 V median; overall power rank #295 (125,083 W, top 12.6%; higher than 87.4% of peers).

NEC 705.12 Check

175 A Required Backfeed OCPD

125% x 120.4 A = 150.5 A -> 175 A standard OCPD using 2/0 AWG Cu (75 C).

MPPT Window

860 V - 1,250 V (Max 1,250 V DC)

Tracking span of 390.0 V; listed since 2021-12-01 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 600 V, 3-phase switchgear (200A Bus / 200A Main (600V) to 1,200A Bus / 1,200A Main (600V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 125083.0W / 600 V 3-phase -> 120.4 A | Breaker >= 1.25 * 120.4 = 150.5 A -> 175 A

CEC Inverters.csv for CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V}: Paco=125083.0 W, Vac=600 V, Vdcmax=1250.0 V, Eff=98.35%.

Result: Min 175 A breaker & 2/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (600V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V}.

Official California Energy Commission (NREL SAM) test parameters for CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 125,083 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 600 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,250 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 860 V - 1,250 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 117.756 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.35% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2021-12-01 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} (600 V, 3-phase)?

Evaluates CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} (175 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} (175 A required OCPD at 600 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (600V) 40 A 175 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (600V) 80 A 175 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (600V) 120 A 175 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (600V) 160 A 175 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (600V) 240 A 175 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V}?

Sample PV string lengths aligned within 860-1,250 V MPPT and 1,250 V DC max at -10 C. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sampled CEC PV modules aligned within 860.0-1250.0 V MPPT and 1250.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 21 to 22 panels 12.98 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 26 to 29 panels 12.76 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 25 to 27 panels 11.47 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 30 panels (fixed) 6.0 kW

Which Competing Grid-Support Inverters Compare to CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V}?

Competing CEC grid-support inverters near 125,083 W AC and 600 V, 3-phase, led by Ginlong Technologies Co Ltd: Solis-125K1-EHV-5G {600V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Ginlong Technologies Co Ltd: Solis-125K1-EHV-5G {600V}
Ginlong Technologies Co Ltd
125,083 W Tie (0 W) 600.0 V 1250.0 V 98.35%
Chint Power Systems America: CPS SCH125KTL-AIO/US-600 {600V}
Chint Power Systems America
125,000 W -83 W 600.0 V 1300.0 V 98.2%
Chint Power Systems America: CPS SCH125KTL-DO/US-600 {600V}
Chint Power Systems America
125,000 W -83 W 600.0 V 1300.0 V 98.21%
Ginlong Technologies Co Ltd: Solis-125K-EHV-5G {600V}
Ginlong Technologies Co Ltd
125,000 W -83 W 600.0 V 1250.0 V 98.63%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V}?

Check CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} (125,083 W AC, 175 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,250 V DC on CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V}.

CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} Panel & Wire Spec

Size 75 C copper conductors at 2/0 AWG Cu on a 175 A OCPD breaker (120.4 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.35%) and MPPT window (860-1,250 V) directly against Ginlong Technologies Co Ltd: Solis-125K1-EHV-5G {600V} (125,083 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} by CSI Solar Co Ltd covering breaker sizing, MPPT limits, and 600 V, 3-phase interconnection.

What breaker and wire size does CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} require?

At 125,083 W continuous AC (600 V, 3-phase), continuous current is 120.4 A; 125% NEC 690.8/705.12 sizing requires a 175 A breaker and 2/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} require?

At 125,083 W AC and 600 V, 3-phase, continuous line current is 120.4 A, requiring a 175 A OCPD and 1,200A Bus / 1,200A Main (600V) or NEC 705.11 interconnection.

How does CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} compare to Ginlong Technologies Co Ltd: Solis-125K1-EHV-5G {600V}?

CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V} delivers 125,083 W AC at 98.35% CEC efficiency with a 1,250 V DC ceiling, while Ginlong Technologies Co Ltd: Solis-125K1-EHV-5G {600V} outputs 125,083 W at 600 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.