Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T is a 590.0 W STC (552.7 W PTC) Mono-c-Si solar module ranking #1,597 of 21,677 CEC listings (top 8.1%; higher than 91.9% of peers). It delivers 21.38% efficiency, 41.1 V Voc at 25 C, and 45.0 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 590.0 W
- PTC Wattage
- 552.7 W
- Voc @ 25C
- 41.1 V
- Efficiency
- 21.38%
How Does Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T Compare Against Peer CEC Listings?
How Zhejiang Sunpro Power Technology Co Ltd Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T handles rooftop heat (552.7 W PTC), 8 kW sizing, and cold winter string voltage.
Zhejiang Sunpro Power Technology Co Ltd builds the Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T (Mono-c-Si) as a large-format commercial and ground-mount module delivering 213.8 W/m2 (1.47 percentage points above 19.91% CEC median). Compared against G-Star Pte Ltd GSD8J60M-595BT (595.0 W), this model holds strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677). Mid-range 41.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 28.74 A overcurrent floor served by a 30 A breaker.
Where Does Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T Fall Across Listed CEC Models?
Where Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T (590.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T?
Percentile placement of Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T across power density (213.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T?
Four critical engineering numbers homeowners and solar installers check first when reviewing Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T specifications.
Top 8.1% STC Output
590.0 W STC (+205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.38% Aperture Efficiency
Power density 213.8 W/m2 (1.47 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.0 V at -10 C (585.0 V string) and 46.11 V at -20 C (13 max).
14 Panels = 8,260 W STC
Occupies 38.6 m2 (416 sq ft) producing 7,738 W PTC; NEC 690.8 OCPD floor is 28.74 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.1 * (1 + (-0.271/100) * (-10 - 25)) = 45.0 V | OCPD = 1.56 * 18.42 = 28.74 A
Inputs from CEC Modules.csv for Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T: Voc=41.1 V, beta_Voc=-0.271%/C, Isc=18.42 A, STC=590.0 W, Area=2.76 m2.
Result: 13 panels max on 600 V (585.0 V); 14 panels for 8 kW (416 sq ft).
What Are the Published CEC Specifications for Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 590.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 552.7 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.42 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.0 V / 17.35 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.38% (2.76 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T (590.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.49 kW | 327 sq ft | $1,624 | $2,747 |
| 8 kW Class | 14 | 8.26 kW | 416 sq ft | $2,067 | $3,496 |
| 10 kW Class | 17 | 10.03 kW | 505 sq ft | $2,510 | $4,245 |
Which Sibling Wattage & Trim Variants Belong to This Zhejiang Sunpro Power Technology Co Ltd Series?
All closely matched Zhejiang Sunpro Power Technology Co Ltd wattages and cosmetic trims sharing the Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Zhejiang Sunpro Power Technology Co Ltd SP580-120M12T | 580.0 W | 543.1 W | 40.7 V | 33.6 V | 21.01% |
| Zhejiang Sunpro Power Technology Co Ltd SP585-120M12T | 585.0 W | 547.9 W | 40.9 V | 33.8 V | 21.2% |
| Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T | 590.0 W | 552.7 W | 41.1 V | 34.0 V | 21.38% |
| Zhejiang Sunpro Power Technology Co Ltd SP595-120M12T | 595.0 W | 557.5 W | 41.3 V | 34.2 V | 21.56% |
How Many Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T Modules Fit in a Cold-Weather String?
Maximum series module counts for Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.11 V | 13 panels | 599.4 V | 21 panels |
| -10 C (14 F) | 45.0 V | 13 panels | 585.0 V | 22 panels |
| 0 C (32 F) | 43.88 V | 13 panels | 570.4 V | 22 panels |
| 25 C (77 F STC) | 41.1 V | 14 panels | 575.4 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T?
Alternative CEC solar modules from competing brands near Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T (590.0 W), including G-Star Pte Ltd GSD8J60M-595BT.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| G-Star Pte Ltd GSD8J60M-595BT G-Star Pte Ltd |
595.0 W | +5.0 W | 41.4 V | 21.17% | 94.2% |
| G-Star Pte Ltd GSD8J60M-595WT G-Star Pte Ltd |
595.0 W | +5.0 W | 41.4 V | 21.17% | 94.2% |
| CSI Solar Co Ltd CS7L-585MS-R CSI Solar Co Ltd |
585.0 W | -5.0 W | 40.7 V | 20.89% | 94.0% |
| Chint New Energy Technology Co Ltd CHSM66RN(DG)/F-BH-590 Chint New Energy Technology Co Ltd |
590.0 W | Tie (0 W) | 48.14 V | 21.85% | 95.3% |
What Are the Design Limits and Best-Fit Uses for Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T?
Evaluate Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T (590.0 W STC, 41.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T reaches 46.11 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 416 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T 8 kW Residential Fit
Needs 14 modules (416 sq ft) with a 30 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare G-Star Pte Ltd GSD8J60M-595BT.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 552.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T by Zhejiang Sunpro Power Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T?
Multiplying Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T's 18.42 A short-circuit current by 1.56 equals 28.74 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.
Can Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.0 V cold Voc at 14 F and handles 18.42 A Isc; string inverters cap Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T at 13 panels on 600 V.
Is Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)