Vietnam Sunergy Joint Stock Company VSUN465N-120MH is a 465.0 W STC (433.8 W PTC) Mono-c-Si solar module ranking #5,072 of 21,677 CEC listings (top 24.0%; higher than 76.0% of peers). It delivers 21.53% efficiency, 42.25 V Voc at 25 C, and 46.35 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 465.0 W
- PTC Wattage
- 433.8 W
- Voc @ 25C
- 42.25 V
- Efficiency
- 21.53%
How Does Vietnam Sunergy Joint Stock Company VSUN465N-120MH Compare Against Peer CEC Listings?
Solar engineering breakdown for Vietnam Sunergy Joint Stock Company VSUN465N-120MH: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Vietnam Sunergy Joint Stock Company and peers, Vietnam Sunergy Joint Stock Company VSUN465N-120MH stands 55.0 W above the 410.0 W Mono-c-Si median and strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Sizing 6 kW (13 panels) to 10 kW (22 panels) yields $1,512-$2,560/yr in baseline US bill offset. Mid-range 42.25 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does Vietnam Sunergy Joint Stock Company VSUN465N-120MH Fall Across Listed CEC Models?
Distribution marker showing Vietnam Sunergy Joint Stock Company VSUN465N-120MH (465.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Vietnam Sunergy Joint Stock Company VSUN465N-120MH?
Dataset percentiles tracking Vietnam Sunergy Joint Stock Company VSUN465N-120MH power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Vietnam Sunergy Joint Stock Company VSUN465N-120MH?
Benchmark highlights for Vietnam Sunergy Joint Stock Company VSUN465N-120MH covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 24.0% STC Output
465.0 W STC (+80.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.53% Aperture Efficiency
Power density 215.3 W/m2 (1.62 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 46.35 V at -10 C (556.2 V string) and 47.52 V at -20 C (12 max).
18 Panels = 8,370 W STC
Occupies 38.9 m2 (419 sq ft) producing 7,808 W PTC; NEC 690.8 OCPD floor is 21.34 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 42.25 * (1 + (-0.277/100) * (-10 - 25)) = 46.35 V | OCPD = 1.56 * 13.68 = 21.34 A
Inputs from CEC Modules.csv for Vietnam Sunergy Joint Stock Company VSUN465N-120MH: Voc=42.25 V, beta_Voc=-0.277%/C, Isc=13.68 A, STC=465.0 W, Area=2.16 m2.
Result: 12 panels max on 600 V (556.2 V); 18 panels for 8 kW (419 sq ft).
What Are the Published CEC Specifications for Vietnam Sunergy Joint Stock Company VSUN465N-120MH?
Official CEC datasheet figures for Vietnam Sunergy Joint Stock Company VSUN465N-120MH (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 465.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 433.8 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 42.25 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.68 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.81 V / 12.99 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.277 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.53% (2.16 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Vietnam Sunergy Joint Stock Company VSUN465N-120MH Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Vietnam Sunergy Joint Stock Company VSUN465N-120MH modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.04 kW | 302 sq ft | $1,512 | $2,556 |
| 8 kW Class | 18 | 8.37 kW | 419 sq ft | $2,095 | $3,542 |
| 10 kW Class | 22 | 10.23 kW | 512 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Vietnam Sunergy Joint Stock Company Series?
Consolidated Vietnam Sunergy Joint Stock Company wattage variants sharing the Vietnam Sunergy Joint Stock Company VSUN465N-120MH mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Vietnam Sunergy Joint Stock Company VSUN460N-120MH | 460.0 W | 429.0 W | 41.97 V | 35.55 V | 21.3% |
| Vietnam Sunergy Joint Stock Company VSUN465N-120MH | 465.0 W | 433.8 W | 42.25 V | 35.81 V | 21.53% |
| Vietnam Sunergy Joint Stock Company VSUN470N-120MH | 470.0 W | 438.6 W | 42.51 V | 36.02 V | 21.76% |
How Many Vietnam Sunergy Joint Stock Company VSUN465N-120MH Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Vietnam Sunergy Joint Stock Company VSUN465N-120MH (46.35 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 47.52 V | 12 panels | 570.2 V | 21 panels |
| -10 C (14 F) | 46.35 V | 12 panels | 556.2 V | 21 panels |
| 0 C (32 F) | 45.18 V | 13 panels | 587.3 V | 22 panels |
| 25 C (77 F STC) | 42.25 V | 14 panels | 591.5 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Vietnam Sunergy Joint Stock Company VSUN465N-120MH?
Competing CEC solar panels closest to Vietnam Sunergy Joint Stock Company VSUN465N-120MH in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-120-BFN10-470W-DG.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-120-BFN10-470W-DG Aptos Solar Technology LLC |
470.0 W | +5.0 W | 42.38 V | 21.76% | 94.9% |
| Auxin Solar AXN10M465B Auxin Solar |
465.0 W | Tie (0 W) | 43.72 V | 21.63% | 91.6% |
| Boviet Solar Technology Co Ltd BVM7610M-460-H-HC Boviet Solar Technology Co Ltd |
460.0 W | -5.0 W | 42.49 V | 21.9% | 94.1% |
| CSI Solar Co Ltd CS61-60TM-470H CSI Solar Co Ltd |
470.0 W | +5.0 W | 42.0 V | 21.46% | 94.6% |
What Are the Design Limits and Best-Fit Uses for Vietnam Sunergy Joint Stock Company VSUN465N-120MH?
Evaluate Vietnam Sunergy Joint Stock Company VSUN465N-120MH (465.0 W STC, 42.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Vietnam Sunergy Joint Stock Company VSUN465N-120MH reaches 47.52 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Vietnam Sunergy Joint Stock Company VSUN465N-120MH carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Vietnam Sunergy Joint Stock Company VSUN465N-120MH 8 kW Residential Fit
Needs 18 modules (419 sq ft) with a 25 A string OCPD, offsetting ~$2,095/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-BFN10-470W-DG.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 433.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Vietnam Sunergy Joint Stock Company VSUN465N-120MH by Vietnam Sunergy Joint Stock Company grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Vietnam Sunergy Joint Stock Company VSUN465N-120MH?
Multiplying Vietnam Sunergy Joint Stock Company VSUN465N-120MH's 13.68 A short-circuit current by 1.56 equals 21.34 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Vietnam Sunergy Joint Stock Company VSUN465N-120MH pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 46.35 V cold Voc at 14 F and handles 13.68 A Isc; string inverters cap Vietnam Sunergy Joint Stock Company VSUN465N-120MH at 12 panels on 600 V.
Is Vietnam Sunergy Joint Stock Company VSUN465N-120MH eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Vietnam Sunergy Joint Stock Company VSUN465N-120MH rely on utility bill offset (~$2,095/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)