Vietnam Sunergy Joint Stock Company VSUN325-60M is a 325.0 W STC (299.2 W PTC) Mono-c-Si solar module ranking #14,546 of 21,677 CEC listings (below all-CEC median; higher than 31.1% of peers). It delivers 19.55% efficiency, 40.7 V Voc at 25 C, and 44.56 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 325.0 W
- PTC Wattage
- 299.2 W
- Voc @ 25C
- 40.7 V
- Efficiency
- 19.55%
How Does Vietnam Sunergy Joint Stock Company VSUN325-60M Compare Against Peer CEC Listings?
Solar engineering breakdown for Vietnam Sunergy Joint Stock Company VSUN325-60M: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Vietnam Sunergy Joint Stock Company and peers, Vietnam Sunergy Joint Stock Company VSUN325-60M stands 85.0 W below the 410.0 W Mono-c-Si median and strong 92.1% PTC-to-STC heat retention (#13,846 of 21,677). Sizing 6 kW (19 panels) to 10 kW (31 panels) yields $1,544-$2,520/yr in baseline US bill offset. Mid-range 40.7 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does Vietnam Sunergy Joint Stock Company VSUN325-60M Fall Across Listed CEC Models?
Distribution marker showing Vietnam Sunergy Joint Stock Company VSUN325-60M (325.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Vietnam Sunergy Joint Stock Company VSUN325-60M?
Dataset percentiles tracking Vietnam Sunergy Joint Stock Company VSUN325-60M power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Vietnam Sunergy Joint Stock Company VSUN325-60M?
Benchmark highlights for Vietnam Sunergy Joint Stock Company VSUN325-60M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
325.0 W STC · Higher Than 31.1%
325.0 W STC (-60.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.55% Aperture Efficiency
Power density 195.4 W/m2 (0.36 percentage points below 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.56 V at -10 C (579.3 V string) and 45.66 V at -20 C (13 max).
25 Panels = 8,125 W STC
Occupies 41.6 m2 (448 sq ft) producing 7,480 W PTC; NEC 690.8 OCPD floor is 15.97 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.7 * (1 + (-0.271/100) * (-10 - 25)) = 44.56 V | OCPD = 1.56 * 10.24 = 15.97 A
Inputs from CEC Modules.csv for Vietnam Sunergy Joint Stock Company VSUN325-60M: Voc=40.7 V, beta_Voc=-0.271%/C, Isc=10.24 A, STC=325.0 W, Area=1.663 m2.
Result: 13 panels max on 600 V (579.3 V); 25 panels for 8 kW (448 sq ft).
What Are the Published CEC Specifications for Vietnam Sunergy Joint Stock Company VSUN325-60M?
Official CEC datasheet figures for Vietnam Sunergy Joint Stock Company VSUN325-60M (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 325.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 299.2 W (92.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.24 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.6 V / 9.68 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.55% (1.663 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Vietnam Sunergy Joint Stock Company VSUN325-60M Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Vietnam Sunergy Joint Stock Company VSUN325-60M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.17 kW | 340 sq ft | $1,544 | $2,611 |
| 8 kW Class | 25 | 8.12 kW | 448 sq ft | $2,032 | $3,437 |
| 10 kW Class | 31 | 10.07 kW | 555 sq ft | $2,520 | $4,262 |
How Many Vietnam Sunergy Joint Stock Company VSUN325-60M Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Vietnam Sunergy Joint Stock Company VSUN325-60M (44.56 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.66 V | 13 panels | 593.6 V | 21 panels |
| -10 C (14 F) | 44.56 V | 13 panels | 579.3 V | 22 panels |
| 0 C (32 F) | 43.46 V | 13 panels | 565.0 V | 23 panels |
| 25 C (77 F STC) | 40.7 V | 14 panels | 569.8 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Vietnam Sunergy Joint Stock Company VSUN325-60M?
Competing CEC solar panels closest to Vietnam Sunergy Joint Stock Company VSUN325-60M in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3K-330MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3K-330MS CSI Solar Co Ltd |
330.0 W | +5.0 W | 40.5 V | 20.62% | 93.2% |
| Auxin Solar AXN6M610T325 Auxin Solar |
325.0 W | Tie (0 W) | 42.2 V | 19.98% | 91.9% |
| Boviet Solar Technology Co Ltd BVM6610M-320L-H Boviet Solar Technology Co Ltd |
320.0 W | -5.0 W | 40.95 V | 19.16% | 93.6% |
| GCL System Integration Technology Co Ltd GCL-M6/60320 GCL System Integration Technology Co Ltd |
320.0 W | -5.0 W | 40.3 V | 19.63% | 91.3% |
What Are the Design Limits and Best-Fit Uses for Vietnam Sunergy Joint Stock Company VSUN325-60M?
Evaluate Vietnam Sunergy Joint Stock Company VSUN325-60M (325.0 W STC, 40.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Vietnam Sunergy Joint Stock Company VSUN325-60M reaches 45.66 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 448 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (448 sq ft).
- 2026 tax credit baseline: cash residential installs of Vietnam Sunergy Joint Stock Company VSUN325-60M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Vietnam Sunergy Joint Stock Company VSUN325-60M 8 kW Residential Fit
Needs 25 modules (448 sq ft) with a 20 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS3K-330MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 299.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Vietnam Sunergy Joint Stock Company VSUN325-60M by Vietnam Sunergy Joint Stock Company grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Vietnam Sunergy Joint Stock Company VSUN325-60M?
Multiplying Vietnam Sunergy Joint Stock Company VSUN325-60M's 10.24 A short-circuit current by 1.56 equals 15.97 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Vietnam Sunergy Joint Stock Company VSUN325-60M pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 44.56 V cold Voc at 14 F and handles 10.24 A Isc; string inverters cap Vietnam Sunergy Joint Stock Company VSUN325-60M at 13 panels on 600 V.
Is Vietnam Sunergy Joint Stock Company VSUN325-60M eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Vietnam Sunergy Joint Stock Company VSUN325-60M rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)