Manufacturer: Universal Solar Americas SA Registry: CEC Verified Engineering Specification

Universal Solar Americas SA UNI455-120M-BB is a 455.0 W STC (418.9 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.16% efficiency, 42.3 V Voc at 25 C, and 46.62 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
455.0 W
PTC Wattage
418.9 W
Voc @ 25C
42.3 V
Efficiency
21.16%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Universal Solar Americas SA UNI455-120M-BB Compare Against Peer CEC Listings?

Solar engineering breakdown for Universal Solar Americas SA UNI455-120M-BB: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Universal Solar Americas SA and peers, Universal Solar Americas SA UNI455-120M-BB stands 45.0 W above the 410.0 W Mono-c-Si median and strong 92.1% PTC-to-STC heat retention (#13,846 of 21,677). Sizing 6 kW (14 panels) to 10 kW (22 panels) yields $1,594-$2,505/yr in baseline US bill offset. Mid-range 42.3 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Universal Solar Americas SA UNI455-120M-BB Fall Across Listed CEC Models?

Distribution marker showing Universal Solar Americas SA UNI455-120M-BB (455.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Universal Solar Americas SA UNI455-120M-BB (455.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUniversal Solar Am: 455.0 W

What Dataset Percentiles Define Universal Solar Americas SA UNI455-120M-BB?

Dataset percentiles tracking Universal Solar Americas SA UNI455-120M-BB power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Universal Solar Americas SA UNI455-120M-BB Engineering BenchmarksPercentile comparison of Universal Solar Americas SA UNI455-120M-BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage455.0 WPTC/STC Retention92.1%Module Efficiency21.16%

What Do the Dataset Ranks Show for Universal Solar Americas SA UNI455-120M-BB?

Benchmark highlights for Universal Solar Americas SA UNI455-120M-BB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #5,417 / 21,677

Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,699

21.16% Aperture Efficiency

Power density 211.6 W/m2 (1.25 percentage points above 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 46.62 V at -10 C (559.4 V string) and 47.86 V at -20 C (12 max).

8 kW Reference Array

18 Panels = 8,190 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,540 W PTC; NEC 690.8 OCPD floor is 21.26 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 42.3 * (1 + (-0.292/100) * (-10 - 25)) = 46.62 V | OCPD = 1.56 * 13.63 = 21.26 A

Inputs from CEC Modules.csv for Universal Solar Americas SA UNI455-120M-BB: Voc=42.3 V, beta_Voc=-0.292%/C, Isc=13.63 A, STC=455.0 W, Area=2.15 m2.

Result: 12 panels max on 600 V (559.4 V); 18 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for Universal Solar Americas SA UNI455-120M-BB?

Official CEC datasheet figures for Universal Solar Americas SA UNI455-120M-BB (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Universal Solar Americas SA UNI455-120M-BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 455.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 418.9 W (92.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 42.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.63 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.2 V / 12.93 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.292 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.16% (2.15 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Universal Solar Americas SA UNI455-120M-BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Universal Solar Americas SA UNI455-120M-BB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.37 kW 324 sq ft $1,594 $2,696
8 kW Class 18 8.19 kW 417 sq ft $2,050 $3,466
10 kW Class 22 10.01 kW 509 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Universal Solar Americas SA Series?

Consolidated Universal Solar Americas SA wattage variants sharing the Universal Solar Americas SA UNI455-120M-BB mechanical and cell layout.

Sibling CEC listings grouped into the Universal Solar Americas SA UNI455-120M-BB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Universal Solar Americas SA UNI450-120M-BB 450.0 W 414.1 W 42.1 V 35.0 V 20.93%
Universal Solar Americas SA UNI455-120M-BB 455.0 W 418.9 W 42.3 V 35.2 V 21.16%

How Many Universal Solar Americas SA UNI455-120M-BB Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Universal Solar Americas SA UNI455-120M-BB (46.62 V at 14 F).

Computed from Voc=42.3V and beta_Voc=-0.292%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 47.86 V 12 panels 574.3 V 20 panels
-10 C (14 F) 46.62 V 12 panels 559.4 V 21 panels
0 C (32 F) 45.39 V 13 panels 590.1 V 22 panels
25 C (77 F STC) 42.3 V 14 panels 592.2 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to Universal Solar Americas SA UNI455-120M-BB?

Competing CEC solar panels closest to Universal Solar Americas SA UNI455-120M-BB in nameplate wattage and Voc, starting with DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW455M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW455M
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD
455.0 W Tie (0 W) 41.73 V 23.95% 94.8%
Aptos Solar Technology LLC DNA-120-MF10-455W-USAptos1
Aptos Solar Technology LLC
455.0 W Tie (0 W) 41.65 V 21.26% 94.3%
Aptos Solar Technology LLC DNA-120-MF10-455W-USAptos2
Aptos Solar Technology LLC
455.0 W Tie (0 W) 41.65 V 21.26% 94.3%
CertainTeed CTM10455HC11-06
CertainTeed
455.0 W Tie (0 W) 41.33 V 21.06% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Universal Solar Americas SA UNI455-120M-BB?

Evaluate Universal Solar Americas SA UNI455-120M-BB (455.0 W STC, 42.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Universal Solar Americas SA UNI455-120M-BB reaches 47.86 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 417 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (417 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Universal Solar Americas SA UNI455-120M-BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Universal Solar Americas SA UNI455-120M-BB 8 kW Residential Fit

Needs 18 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW455M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 418.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Universal Solar Americas SA UNI455-120M-BB by Universal Solar Americas SA grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Universal Solar Americas SA UNI455-120M-BB?

Multiplying Universal Solar Americas SA UNI455-120M-BB's 13.63 A short-circuit current by 1.56 equals 21.26 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Universal Solar Americas SA UNI455-120M-BB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 46.62 V cold Voc at 14 F and handles 13.63 A Isc; string inverters cap Universal Solar Americas SA UNI455-120M-BB at 12 panels on 600 V.

Is Universal Solar Americas SA UNI455-120M-BB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Universal Solar Americas SA UNI455-120M-BB rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.