Universal Solar Americas SA UNI455-120M-BB is a 455.0 W STC (418.9 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.16% efficiency, 42.3 V Voc at 25 C, and 46.62 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 455.0 W
- PTC Wattage
- 418.9 W
- Voc @ 25C
- 42.3 V
- Efficiency
- 21.16%
How Does Universal Solar Americas SA UNI455-120M-BB Compare Against Peer CEC Listings?
Solar engineering breakdown for Universal Solar Americas SA UNI455-120M-BB: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Universal Solar Americas SA and peers, Universal Solar Americas SA UNI455-120M-BB stands 45.0 W above the 410.0 W Mono-c-Si median and strong 92.1% PTC-to-STC heat retention (#13,846 of 21,677). Sizing 6 kW (14 panels) to 10 kW (22 panels) yields $1,594-$2,505/yr in baseline US bill offset. Mid-range 42.3 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does Universal Solar Americas SA UNI455-120M-BB Fall Across Listed CEC Models?
Distribution marker showing Universal Solar Americas SA UNI455-120M-BB (455.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Universal Solar Americas SA UNI455-120M-BB?
Dataset percentiles tracking Universal Solar Americas SA UNI455-120M-BB power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Universal Solar Americas SA UNI455-120M-BB?
Benchmark highlights for Universal Solar Americas SA UNI455-120M-BB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 26.2% STC Output
455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.16% Aperture Efficiency
Power density 211.6 W/m2 (1.25 percentage points above 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 46.62 V at -10 C (559.4 V string) and 47.86 V at -20 C (12 max).
18 Panels = 8,190 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,540 W PTC; NEC 690.8 OCPD floor is 21.26 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 42.3 * (1 + (-0.292/100) * (-10 - 25)) = 46.62 V | OCPD = 1.56 * 13.63 = 21.26 A
Inputs from CEC Modules.csv for Universal Solar Americas SA UNI455-120M-BB: Voc=42.3 V, beta_Voc=-0.292%/C, Isc=13.63 A, STC=455.0 W, Area=2.15 m2.
Result: 12 panels max on 600 V (559.4 V); 18 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Universal Solar Americas SA UNI455-120M-BB?
Official CEC datasheet figures for Universal Solar Americas SA UNI455-120M-BB (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 418.9 W (92.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 42.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.63 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.2 V / 12.93 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.292 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.16% (2.15 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Universal Solar Americas SA UNI455-120M-BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Universal Solar Americas SA UNI455-120M-BB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.37 kW | 324 sq ft | $1,594 | $2,696 |
| 8 kW Class | 18 | 8.19 kW | 417 sq ft | $2,050 | $3,466 |
| 10 kW Class | 22 | 10.01 kW | 509 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This Universal Solar Americas SA Series?
Consolidated Universal Solar Americas SA wattage variants sharing the Universal Solar Americas SA UNI455-120M-BB mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Universal Solar Americas SA UNI450-120M-BB | 450.0 W | 414.1 W | 42.1 V | 35.0 V | 20.93% |
| Universal Solar Americas SA UNI455-120M-BB | 455.0 W | 418.9 W | 42.3 V | 35.2 V | 21.16% |
How Many Universal Solar Americas SA UNI455-120M-BB Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Universal Solar Americas SA UNI455-120M-BB (46.62 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 47.86 V | 12 panels | 574.3 V | 20 panels |
| -10 C (14 F) | 46.62 V | 12 panels | 559.4 V | 21 panels |
| 0 C (32 F) | 45.39 V | 13 panels | 590.1 V | 22 panels |
| 25 C (77 F STC) | 42.3 V | 14 panels | 592.2 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Universal Solar Americas SA UNI455-120M-BB?
Competing CEC solar panels closest to Universal Solar Americas SA UNI455-120M-BB in nameplate wattage and Voc, starting with DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW455M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW455M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
455.0 W | Tie (0 W) | 41.73 V | 23.95% | 94.8% |
| Aptos Solar Technology LLC DNA-120-MF10-455W-USAptos1 Aptos Solar Technology LLC |
455.0 W | Tie (0 W) | 41.65 V | 21.26% | 94.3% |
| Aptos Solar Technology LLC DNA-120-MF10-455W-USAptos2 Aptos Solar Technology LLC |
455.0 W | Tie (0 W) | 41.65 V | 21.26% | 94.3% |
| CertainTeed CTM10455HC11-06 CertainTeed |
455.0 W | Tie (0 W) | 41.33 V | 21.06% | 93.8% |
What Are the Design Limits and Best-Fit Uses for Universal Solar Americas SA UNI455-120M-BB?
Evaluate Universal Solar Americas SA UNI455-120M-BB (455.0 W STC, 42.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Universal Solar Americas SA UNI455-120M-BB reaches 47.86 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 417 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (417 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Universal Solar Americas SA UNI455-120M-BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Universal Solar Americas SA UNI455-120M-BB 8 kW Residential Fit
Needs 18 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW455M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 418.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Universal Solar Americas SA UNI455-120M-BB by Universal Solar Americas SA grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Universal Solar Americas SA UNI455-120M-BB?
Multiplying Universal Solar Americas SA UNI455-120M-BB's 13.63 A short-circuit current by 1.56 equals 21.26 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Universal Solar Americas SA UNI455-120M-BB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 46.62 V cold Voc at 14 F and handles 13.63 A Isc; string inverters cap Universal Solar Americas SA UNI455-120M-BB at 12 panels on 600 V.
Is Universal Solar Americas SA UNI455-120M-BB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Universal Solar Americas SA UNI455-120M-BB rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)