Skip to main content
WireAndSun
Calculators
CEC PV Module

United Renewable Energy Co Ltd FAK485CAG — CEC Solar Module Specifications

Manufacturer: United Renewable Energy Co Ltd Registry: CEC Verified Engineering Specification

United Renewable Energy Co Ltd FAK485CAG is a 485.0 W STC (450.8 W PTC) Mono-c-Si solar module ranking #4,730 of 21,677 CEC listings (top 22.2%; higher than 77.8% of peers). It delivers 20.29% efficiency, 53.3 V Voc at 25 C, and 58.6 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
485.0 W
PTC Wattage
450.8 W
Voc @ 25C
53.3 V
Efficiency
20.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does United Renewable Energy Co Ltd FAK485CAG Compare Against Peer CEC Listings?

How United Renewable Energy Co Ltd United Renewable Energy Co Ltd FAK485CAG handles rooftop heat (450.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, United Renewable Energy Co Ltd FAK485CAG exhibits 11.48 A short-circuit current, requiring a 17.91 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #4,730 of 21,677 (75.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 40.6 m2 for an 8 kW system (21 panels for 10 kW). Higher 53.3 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does United Renewable Energy Co Ltd FAK485CAG Fall Across Listed CEC Models?

Where United Renewable Energy Co Ltd FAK485CAG (485.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where United Renewable Energy Co Ltd FAK485CAG (485.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUnited Renewable E: 485.0 W

What Dataset Percentiles Define United Renewable Energy Co Ltd FAK485CAG?

Percentile placement of United Renewable Energy Co Ltd FAK485CAG across power density (202.9 W/m2), thermal retention, and nameplate STC wattage.

United Renewable Energy Co Ltd FAK485CAG Engineering BenchmarksPercentile comparison of United Renewable Energy Co Ltd FAK485CAG wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage485.0 WPTC/STC Retention92.9%Module Efficiency20.29%

What Do the Dataset Ranks Show for United Renewable Energy Co Ltd FAK485CAG?

Four critical engineering numbers homeowners and solar installers check first when reviewing United Renewable Energy Co Ltd FAK485CAG specifications.

Rank #4,730 / 21,677

Top 22.2% STC Output

485.0 W STC (+100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,391

20.29% Aperture Efficiency

Power density 202.9 W/m2 (0.38 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 58.6 V at -10 C (586.0 V string) and 60.11 V at -20 C (9 max).

8 kW Reference Array

17 Panels = 8,245 W STC

Occupies 40.6 m2 (437 sq ft) producing 7,664 W PTC; NEC 690.8 OCPD floor is 17.91 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.3 * (1 + (-0.284/100) * (-10 - 25)) = 58.6 V | OCPD = 1.56 * 11.48 = 17.91 A

Inputs from CEC Modules.csv for United Renewable Energy Co Ltd FAK485CAG: Voc=53.3 V, beta_Voc=-0.284%/C, Isc=11.48 A, STC=485.0 W, Area=2.39 m2.

Result: 10 panels max on 600 V (586.0 V); 17 panels for 8 kW (437 sq ft).

What Are the Published CEC Specifications for United Renewable Energy Co Ltd FAK485CAG?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for United Renewable Energy Co Ltd FAK485CAG.

Official California Energy Commission (NREL SAM) test parameters for United Renewable Energy Co Ltd FAK485CAG.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 485.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 450.8 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 53.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.48 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 44.5 V / 10.9 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.284 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.29% (2.39 m2) Array roof footprint density
Cell Count & Technology 78 cells (Mono-c-Si) Bifacial glass-glass

How Many United Renewable Energy Co Ltd FAK485CAG Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using United Renewable Energy Co Ltd FAK485CAG (485.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.3 kW 334 sq ft $1,577 $2,666
8 kW Class 17 8.24 kW 437 sq ft $2,062 $3,487
10 kW Class 21 10.19 kW 540 sq ft $2,550 $4,313

Which Sibling Wattage & Trim Variants Belong to This United Renewable Energy Co Ltd Series?

All closely matched United Renewable Energy Co Ltd wattages and cosmetic trims sharing the United Renewable Energy Co Ltd FAK485CAG architecture.

Sibling CEC listings grouped into the United Renewable Energy Co Ltd FAK485CAG wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
United Renewable Energy Co Ltd FAK475CAG 475.0 W 441.2 W 52.9 V 44.1 V 19.87%
United Renewable Energy Co Ltd FAK480CAG 480.0 W 446.0 W 53.1 V 44.3 V 20.08%
United Renewable Energy Co Ltd FAK485CAG 485.0 W 450.8 W 53.3 V 44.5 V 20.29%
United Renewable Energy Co Ltd FAK490CAG 490.0 W 455.5 W 53.5 V 44.7 V 20.5%
United Renewable Energy Co Ltd FAK495CAG 495.0 W 460.3 W 53.7 V 44.9 V 20.71%

How Many United Renewable Energy Co Ltd FAK485CAG Modules Fit in a Cold-Weather String?

Maximum series module counts for United Renewable Energy Co Ltd FAK485CAG from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=53.3V and beta_Voc=-0.284%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 60.11 V 9 panels 541.0 V 16 panels
-10 C (14 F) 58.6 V 10 panels 586.0 V 17 panels
0 C (32 F) 57.08 V 10 panels 570.8 V 17 panels
25 C (77 F STC) 53.3 V 11 panels 586.3 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd FAK485CAG?

Alternative CEC solar modules from competing brands near United Renewable Energy Co Ltd FAK485CAG (485.0 W), including CSI Solar Co Ltd CS3Y-485MB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3Y-485MB-AG
CSI Solar Co Ltd
485.0 W Tie (0 W) 53.1 V 21.09% 93.5%
CSI Solar Co Ltd CS3Y-480PB-AG
CSI Solar Co Ltd
480.0 W -5.0 W 52.8 V 20.87% 93.9%
CSI Solar Co Ltd CS3Y-470MB-AG
CSI Solar Co Ltd
470.0 W -15.0 W 52.5 V 20.43% 93.4%
CSI Solar Co Ltd CS3Y-460PB-AG
CSI Solar Co Ltd
460.0 W -25.0 W 52.0 V 20.0% 93.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd FAK485CAG?

Evaluate United Renewable Energy Co Ltd FAK485CAG (485.0 W STC, 53.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd FAK485CAG reaches 60.11 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 17 panels for an 8 kW build require 437 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (437 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd FAK485CAG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

United Renewable Energy Co Ltd FAK485CAG 8 kW Residential Fit

Needs 17 modules (437 sq ft) with a 20 A string OCPD, offsetting ~$2,062/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 9 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-485MB-AG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 450.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for United Renewable Energy Co Ltd FAK485CAG by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is United Renewable Energy Co Ltd FAK485CAG PTC wattage (450.8 W) lower than STC (485.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 450.8 W PTC (92.9% retention) across United Renewable Energy Co Ltd FAK485CAG's 2.39 m2 aperture.

Who should skip United Renewable Energy Co Ltd FAK485CAG on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 17 United Renewable Energy Co Ltd FAK485CAG panels (437 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3Y-485MB-AG.

What is the 1,000 V commercial string limit for United Renewable Energy Co Ltd FAK485CAG?

On 1,000 V commercial inverters at -10 C (58.6 V cold Voc), United Renewable Energy Co Ltd FAK485CAG fits up to 17 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.